background image

• Indoor Unit • Ceiling suspended unit • FHQG-C

• Split - Sky Air

®

 • Indoor Unit

6

5

Dimensional drawings

5 - 1 Dimensional Drawings

FHQG71

3D069632

NOTES

Location of unit’s of name plate: bottom of fan housing inside the 
suction grille.

In case of using infrared remote control, this position will be a signal 
receiver. Refer to the drawing of infrared remote control in detail.

Please do not place the thing been damp and troubled under an 
indoor unit. When the case where humidity is 80% or more, the drain 
outlet are choked up and the air fi lter are dirty, dew may fall.

Nr

Name

Description

1

Air discharge grille

2

Air suction grille

3

Air fi lter

4

Gas pipe connection

Ø15.9 fl are

5

Liquid pipe connection

Ø9.5 fl are

6

Drain pipe connection

VP20

7

Earth terminal (inside electric components box)

M4

8

Hanger bracket

9

Backward piping and wiring connection opening lid

10 Upward piping and wiring connection opening lid

11 Right side pipe connection

slit hole

12 Left back drain pipe connection

slit hole

13 Left side drain pipe connection

slit hole

14 Right side drain pipe connection

slit hole

15 Hole of wall for taking out in piping back

Ø100

16 Upward drain pipe connection

Ø60

17 Upward gas pipe connection

Ø36

18 Upward liquid pipe connection

Ø26

19 Power source wiring and a unit wiring back connection

Ø29

20 Power source wiring and a unit wiring upper connection

Ø29

(suspension position)

Position slit hole for taking out in piping back

(view from the front)

Position: hole of wall for taking out in piping back

(view from the front)

(suspension

position)

(required space)

(required space)

(required space)

For height installation from the 

fl oor side 2500 or more

Drain pipe 

connection VP20

suspension bolt

brand nameplate
note 2

fl oor side

obstacle

30 or more

(service space)

30 or more
(service space)

Connection position of fresh air intake kit
Ø100 (knock-out hole)

THE FRONT

(for left piping)

300 or more

FHQG100-140

3D069633

NOTES

Location of unit’s name plate: bottom of fan housing inside the suction grille.

In case of using infrared remote control, this position will be a signal 
receiver. Refer to the drawing of infrared remote control in detail.

Don’t put anything under indoor unit because dew may fall by reason 
of following:
1. The humidity is 80% or more.
2. The drain outlet is stopped up.
3. The air fi lter is dirty.

Nr

Name

Description

1

Air discharge grille

2

Air suction grille

3

Air fi lter

4

Gas pipe connection

Ø15.9 fl are

5

Liquid pipe connection

Ø9.5 fl are

6

Drain pipe connection

VP20

7

Earth terminal (inside electric components box)

M4

8

Hanger bracket

9

Backward piping and wiring connection opening lid

10 Upward piping and wiring connection opening lid

11 Right side pipe connection

slit hole

12 Left back drain pipe connection

slit hole

13 Left side drain pipe connection

slit hole

14 Right side drain pipe connection

slit hole

15 Hole of wall for taking out in piping back

Ø100

16 Upward drain pipe connection

Ø60

17 Upward gas pipe connection

Ø36

18 Upward liquid pipe connection

Ø26

19 Power source wiring and a unit wiring back connection

Ø29

20 Power source wiring and a unit wiring upper connection

Ø29

(suspension position)

Position slit hole for taking out in piping back

(view from the front)

Position: hole of wall for taking out in piping back

(view from the front)

(suspension

position)

(required space)

(required space)

(required space)

For height installation from the 

fl oor side 2500 or more

Drain pipe connection VP20

suspension bolt

brand nameplate
note 2

brand nameplate

fl oor side

obstacle

30 or more

(service space)

30 or more
(service space)

Connection position of fresh air intake kit
Ø100 (knock-out hole)

FRONT

Summary of Contents for SkyAir GQI-Eco FHQG100CVEB

Page 1: ...FHQG C C e i l i n g S u s p e n d e d C a s s e t t e w w w d a i k i n e u Air Conditioners Technical Data...

Page 2: ...FHQG C C e i l i n g S u s p e n d e d C a s s e t t e w w w d a i k i n e u Air Conditioners Technical Data...

Page 3: ...cations 3 Technical Specifications 3 Electrical Specifications 3 3 Safety device settings 4 Safety Device Settings 4 4 Options 5 Options 5 5 Dimensional drawings 6 Dimensional Drawings 6 6 Piping diag...

Page 4: ...e i l i n g s u s S p l i t S k Seasonal efficiency optimized for all seasons Can be installed in both new and existing buildings Ideal solution for shops restaurants or offices without false ceiling...

Page 5: ...an Air flow rate Cooling High m min 20 5 28 31 34 Low m min 14 20 23 24 Heating High m min 20 5 28 31 34 Low m min 14 20 23 24 Fan motor Model 3D15L1AA1 4D15L1AC1 Sound power level Cooling Nom dBA 55...

Page 6: ...Air Indoor Unit 4 3 Safety device settings 3 1 Safety Device Settings FHQG CVEB 3D069638 SAFETY DEVICE LIST Safety devices 71 100 125 140 FHQG CVEB Fuse 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A Fa...

Page 7: ...Remote control Wired BRC1E51A7 BRC1D528 Wireless Heat pump BRC7G63 Wiring adapter for electrical appendices 2 KRP1BA54 Wiring adapter for electrical appendices 2 KRP4AA52 Installation box for adapter...

Page 8: ...note 2 oor side obstacle 30 or more service space 30 or more service space Connection position of fresh air intake kit 100 knock out hole THE FRONT for left piping 300 or more FHQG100 140 3D069633 NO...

Page 9: ...5 1 Dimensional Drawings FHQG CVEB 3D069661 Remote controller dimensions Transmitting part Receiver installation procedure Remote controller holder installation procedure Installation to wall surface...

Page 10: ...suspended unit FHQG C Split Sky Air Indoor Unit 8 6 Piping diagrams 6 1 Piping Diagrams FHQG CVEB 4D037995J Field piping To outdoor unit Field piping Indoor heat exchanger INDOOR UNIT MODEL FHQG71 100...

Page 11: ...ency H2P Light emitting diode X35A Connector group control adapter V1R Diode bridge timer green RED red PNK pink BLK black ORG orange X1M Terminal block H3P Light emitting diode WHT white GRN green YL...

Page 12: ...FURSKRQH 2FWDYH EDQG VRXQG SUHVVXUH OHYHO G G EDU 2FWDYH EDQG FHQWHU IUHTXHQF L RZ SSUR LPDWH WKUHVKROG KHDULQJ IRU FRQWLQXRXV QRLVH 0LF SRVLWLRQ 6FDOH L RZ 4 9 127 6 2YHU OO G 1 LV DOUHDG UHFWL HG 2S...

Page 13: ...products and an energy management system resulting in energy conservation and a reduction of waste Daikin Europe N V is participating in the EUROVENT Certification Programme Products are as listed in...