Si281311
Procedure to Remove PCB Assy (3)
Removal Procedure
7
6. Procedure to Remove PCB Assy (3)
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
3. Remove the PCB assy
(A1P)
PCB assy (Retrieved)
1
Remove the connectors
on the PCB.
2
Remove the 1 screw
that fixes the electric
component to the
mounting plate.
3
Pull out the PCB assy,
after removing from the
hooks at the both sides
(9 locations).
Hooks
Hooks
Fixing screw
X6A
X21A
X5A
X13A
X11A
X41A
X17A
X32A
X25AX77A
X803A
X12A
X106A
X11A
LB
E
LA
NA
LC
W
V
U
DB501
IPM501
DB502
D531
D532
Q501