Removal of Humidifying Duct
Si001080
16
Removal Procedure
6. Removal of Humidifying Duct
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the screw and
remove the stop valve
cover.
2
Remove the screw and
remove the humidifying
duct.
When reassembling, make
sure to catch the hook.
(R14003)
Stop valve
cover
(R14004)
Humidifying duct