Specifications
Notes
(1) Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
(2) 240V
(3) EER/COP according to Eurovent 2012, for use outside EU only
SL: The silent fan level of the air flow rate setting
220V
230V
2-2 Capacity and Power input
FTXG25LS/RXG25L
FTXG20LS/RXG20L
FTXG35LS/RXG35L
FTXG50LS/RXG50L
Cooling capacity
Rated
kW
2.4 (1)
2.3 (1)
3.5 (1)
4.8 (1)
Btu/h
8,200 (1)
7,800 (1)
11,900 (1)
16,400 (1)
kcal/h
2,060 (1)
1,980 (1)
3,010 (1)
4,130 (1)
Min.
kW
1.3 (1)
1.4 (1)
1.7 (1)
Btu/h
4,400 (1)
4,800 (1)
5,800 (1)
kcal/h
1,120 (1)
1,200 (1)
1,460 (1)
Max.
kW
3.0 (1)
2.8 (1)
3.8 (1)
5.3 (1)
Btu/h
10,200 (1)
9,500 (1)
13,000 (1)
18,100 (1)
kcal/h
2,580 (1)
2,410 (1)
3,270 (1)
4,560 (1)
Heating capacity
Rated
kW
3.4 (1)
2.5 (1)
4.0 (1)
5.8 (1)
Btu/h
11,600 (1)
8,500 (1)
13,600 (1)
19,800 (1)
kcal/h
2,920 (1)
2,150 (1)
3,440 (1)
4,990 (1)
Min.
kW
1.3 (1)
1.4 (1)
1.7 (1)
Btu/h
4,400 (1)
4,800 (1)
5,800 (1)
kcal/h
1,120 (1)
1,200 (1)
1,460 (1)
Max.
kW
4.5 (1)
4.3 (1)
5.0 (1)
6.5 (1)
Btu/h
15,400 (1)
14,600 (1)
17,100 (1)
22,200 (1)
kcal/h
3,870 (1)
3,700 (1)
4,300 (1)
5,590 (1)
Power input
Cooling
Min.
kW
0.320 (1)
0.350 (1)
0.370 (1)
Nom.
kW
0.523 (1)
0.501 (1)
0.882 (1)
1.360 (1)
Max.
kW
0.820 (1)
0.760 (1)
1.190 (1)
1.880 (1)
Heating
Min.
kW
0.310 (1)
0.320 (1)
0.310 (1)
Nom.
kW
0.769 (1)
0.500 (1)
0.985 (1)
1.589 (1)
Max.
kW
1.320 (1)
1.120 (1)
1.490 (1)
2.490 (1)
Seasonal efficiency
(according to
EN14825)
Cooling
Energy label
A+++
A++
Pdesign
kW
2.40
2.30
3.50
4.80
SEER
8.50
8.52
7.00
6.70
Annual energy
consumption
kWh
99
94
175
251
Heating (Average
climate)
Energy label
A++
A+
Pdesign
kW
2.70
2.10
3.00
4.60
SCOP/A
4.60
4.24
Annual energy
consumption
kWh
821
639
913
1,519
Piping connections
Liquid
OD
mm
6.35
Gas
OD
mm
9.5
12.7
Drain
OD
mm
18.0
Heat insulation
Both liquid and gas pipes
Current
Nominal running
current (RLA) - 50Hz
Cooling
A
2.9 (2) / 2.8 / 2.7
2.8 (2) / 2.7 / 2.6
5.0 (2) / 4.8 / 4.6
6.5 (2) / 6.2 / 5.9
Heating
A
4.4 (2) / 4.2 / 4.0
2.8 (2) / 2.7 / 2.6
5.5 (2) / 5.3 / 5.1
7.4 (2) / 7.1 / 6.8
Nominal efficiency
EER
4.59 (3)
3.97 (3)
3.53 (3)
COP
4.42 (3)
5.00 (3)
4.06 (3)
3.65 (3)
Annual energy consumption
kWh
261.5
250.5
441
680
Energy label
Cooling
A
Heating
A
Summary of Contents for RXG-L
Page 1: ...Split Air Conditioning Technical Data RXG L...
Page 2: ......
Page 10: ...Outdoor Unit RXG L 3 Split Sky Air RXG L 8 3 Electrical data 3 1 Electrical Data...
Page 11: ...3 3 Split Sky Air RXG L 9 Outdoor Unit RXG L 3 Electrical data 3 1 Electrical Data...
Page 19: ...3 5 Split Sky Air RXG L 17 Outdoor Unit RXG L 5 Dimensional drawings 5 1 Dimensional Drawings...
Page 20: ...Outdoor Unit RXG L 6 Split Sky Air RXG L 18 6 Centre of gravity 6 1 Centre of Gravity...
Page 21: ...3 7 Split Sky Air RXG L 19 Outdoor Unit RXG L 7 Piping diagrams 7 1 Piping Diagrams...
Page 22: ...Outdoor Unit RXG L 8 Split Sky Air RXG L 20 8 Wiring diagrams 8 1 Wiring Diagrams Single Phase...
Page 26: ......