background image

• Outdoor Unit • RXG-L

2

• Split - Sky Air • RXG-L

4

2

Specifications

 Notes

 (1) Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load

 (2) 240V

 (3) EER/COP according to Eurovent 2012, for use outside EU only

 SL: The silent fan level of the air flow rate setting

 220V

 230V

2-2 Capacity and Power input

FTXG25LS/RXG25L

FTXG20LS/RXG20L

FTXG35LS/RXG35L

FTXG50LS/RXG50L

Cooling capacity

Rated

kW

2.4 (1)

2.3 (1)

3.5 (1)

4.8 (1)

Btu/h

8,200 (1)

7,800 (1)

11,900 (1)

16,400 (1)

kcal/h

2,060 (1)

1,980 (1)

3,010 (1)

4,130 (1)

Min.

kW

1.3 (1)

1.4 (1)

1.7 (1)

Btu/h

4,400 (1)

4,800 (1)

5,800 (1)

kcal/h

1,120 (1)

1,200 (1)

1,460 (1)

Max.

kW

3.0 (1)

2.8 (1)

3.8 (1)

5.3 (1)

Btu/h

10,200 (1)

9,500 (1)

13,000 (1)

18,100 (1)

kcal/h

2,580 (1)

2,410 (1)

3,270 (1)

4,560 (1)

Heating capacity

Rated

kW

3.4 (1)

2.5 (1)

4.0 (1)

5.8 (1)

Btu/h

11,600 (1)

8,500 (1)

13,600 (1)

19,800 (1)

kcal/h

2,920 (1)

2,150 (1)

3,440 (1)

4,990 (1)

Min.

kW

1.3 (1)

1.4 (1)

1.7 (1)

Btu/h

4,400 (1)

4,800 (1)

5,800 (1)

kcal/h

1,120 (1)

1,200 (1)

1,460 (1)

Max.

kW

4.5 (1)

4.3 (1)

5.0 (1)

6.5 (1)

Btu/h

15,400 (1)

14,600 (1)

17,100 (1)

22,200 (1)

kcal/h

3,870 (1)

3,700 (1)

4,300 (1)

5,590 (1)

Power input

Cooling

Min.

kW

0.320 (1)

0.350 (1)

0.370 (1)

Nom.

kW

0.523 (1)

0.501 (1)

0.882 (1)

1.360 (1)

Max.

kW

0.820 (1)

0.760 (1)

1.190 (1)

1.880 (1)

Heating

Min.

kW

0.310 (1)

0.320 (1)

0.310 (1)

Nom.

kW

0.769 (1)

0.500 (1)

0.985 (1)

1.589 (1)

Max.

kW

1.320 (1)

1.120 (1)

1.490 (1)

2.490 (1)

Seasonal efficiency 
(according to 
EN14825)

Cooling

Energy label

A+++

A++

Pdesign

kW

2.40

2.30

3.50

4.80

SEER

8.50

8.52

7.00

6.70

Annual energy 
consumption

kWh

99

94

175

251

Heating (Average 
climate)

Energy label

A++

A+

Pdesign

kW

2.70

2.10

3.00

4.60

SCOP/A

4.60

4.24

Annual energy 
consumption

kWh

821

639

913

1,519

Piping connections

Liquid

OD

mm

6.35

Gas

OD

mm

9.5

12.7

Drain

OD

mm

18.0

Heat insulation

Both liquid and gas pipes

Current

Nominal running 
current (RLA) - 50Hz

Cooling

A

2.9 (2) / 2.8 / 2.7

2.8 (2) / 2.7 / 2.6

5.0 (2) / 4.8 / 4.6

6.5 (2) / 6.2 / 5.9

Heating

A

4.4 (2) / 4.2 / 4.0

2.8 (2) / 2.7 / 2.6

5.5 (2) / 5.3 / 5.1

7.4 (2) / 7.1 / 6.8

Nominal efficiency

EER

4.59 (3)

3.97 (3)

3.53 (3)

COP

4.42 (3)

5.00 (3)

4.06 (3)

3.65 (3)

Annual energy consumption

kWh

261.5

250.5

441

680

Energy label

Cooling

A

Heating

A

Summary of Contents for RXG-L

Page 1: ...Split Air Conditioning Technical Data RXG L...

Page 2: ......

Page 3: ...4 Capacity and Power input 5 Technical Specifications 5 Electrical Specifications 7 3 Electrical data 8 4 Capacity tables 10 Cooling Heating Capacity Tables 10 5 Dimensional drawings 17 6 Centre of g...

Page 4: ...tdoor units for pair application Outdoor units are fitted with a swing compressor renowned for its low noise and high energy efficiency Daikin outdoor units are neat sturdy and can easily be mounted o...

Page 5: ...0 1 Max kW 4 3 1 4 5 1 5 0 1 6 5 1 Btu h 14 600 1 15 400 1 17 100 1 22 200 1 kcal h 3 700 1 3 870 1 4 300 1 5 590 1 Power input Cooling Min kW 0 320 1 0 350 1 0 370 1 Nom kW 0 501 1 0 523 1 0 882 1 1...

Page 6: ...1 Max kW 4 5 1 4 3 1 5 0 1 6 5 1 Btu h 15 400 1 14 600 1 17 100 1 22 200 1 kcal h 3 870 1 3 700 1 4 300 1 5 590 1 Power input Cooling Min kW 0 320 1 0 350 1 0 370 1 Nom kW 0 523 1 0 501 1 0 882 1 1 3...

Page 7: ...3 4 2 4 5 2 5 8 2 Btu h 11 600 2 15 400 2 19 800 2 Max kW 4 5 5 0 8 1 Btu h 15 400 17 100 27 600 Power input Cooling Min kW 0 30 0 31 4 50 Nom kW 0 54 0 94 1 51 Max kW 0 79 1 15 2 00 Heating Min kW 0...

Page 8: ...38 3 cfm 932 1 352 Fan motor Model D23H 28 KFD 380 50 8C Output W 23 53 Speed Cooling High rpm 860 920 780 Super low rpm 780 670 Heating High rpm 860 720 Super low rpm 740 670 Sound power level Cooli...

Page 9: ...0L Power supply Name V1 Phase 1 Frequency Hz 50 Voltage V 220 240 Current 50Hz Maximum fuse amps MFA A 16 20 Current Nominal running current RLA Cooling A 2 68 2 2 58 3 2 48 4 2 78 2 2 68 3 2 58 4 4 8...

Page 10: ...Outdoor Unit RXG L 3 Split Sky Air RXG L 8 3 Electrical data 3 1 Electrical Data...

Page 11: ...3 3 Split Sky Air RXG L 9 Outdoor Unit RXG L 3 Electrical data 3 1 Electrical Data...

Page 12: ...Outdoor Unit RXG L 4 Split Sky Air RXG L 10 4 Capacity tables 4 1 Cooling Heating Capacity Tables dy s t Zy s dy s Zy s K K t s s E t t d t t W t d E...

Page 13: ...3 4 Split Sky Air RXG L 11 Outdoor Unit RXG L 4 Capacity tables 4 1 Cooling Heating Capacity Tables dy s t Zy s dy s Zy s K t K s s E t t d t t W t d E...

Page 14: ...Outdoor Unit RXG L 4 Split Sky Air RXG L 12 4 Capacity tables 4 1 Cooling Heating Capacity Tables dy s t Zy s dy s Zy s K t K s s E t t d t t W t d E...

Page 15: ...3 4 Split Sky Air RXG L 13 Outdoor Unit RXG L 4 Capacity tables 4 1 Cooling Heating Capacity Tables dy s t Zy s dy s Zy s K K t s s E t t d t t W t d E d d d...

Page 16: ...Outdoor Unit RXG L 4 Split Sky Air RXG L 14 4 Capacity tables 4 1 Cooling Heating Capacity Tables...

Page 17: ...3 4 Split Sky Air RXG L 15 Outdoor Unit RXG L 4 Capacity tables 4 1 Cooling Heating Capacity Tables...

Page 18: ...Outdoor Unit RXG L 4 Split Sky Air RXG L 16 4 Capacity tables 4 1 Cooling Heating Capacity Tables...

Page 19: ...3 5 Split Sky Air RXG L 17 Outdoor Unit RXG L 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 20: ...Outdoor Unit RXG L 6 Split Sky Air RXG L 18 6 Centre of gravity 6 1 Centre of Gravity...

Page 21: ...3 7 Split Sky Air RXG L 19 Outdoor Unit RXG L 7 Piping diagrams 7 1 Piping Diagrams...

Page 22: ...Outdoor Unit RXG L 8 Split Sky Air RXG L 20 8 Wiring diagrams 8 1 Wiring Diagrams Single Phase...

Page 23: ...dB Sound pressure level dB Heating mode Legend Octave band centre frequency Hz Notes Cooling Heating Operating noise varies depending on operation and ambient conditions dBA A B dBA A B The operation...

Page 24: ...60 Hz JIS standard Background noise already taken into account Total dB Total dB Background noise already taken into account RXG35L 3D086901A 48 48 Location of microphone Measuring location anechoic...