Si001418E
Four Way Valve
Removal Procedure
19
2
Remove the terminal
cover.
3
4
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
5
6
7
Remove the sheet of
putty.
Heat up and disconnect
the every brazed part of
the four way valve.
Remove the four way
valve.
Step
Procedure
Points
Terminal cover
(R20866)
Overload protector
V (yellow)
W (blue)
Protection
bushing
U (red)
(R20867)
Brazed part
Putty
Four way
valve
(R20868)