![Daikin RKS71KAVMA Removal Procedure Download Page 22](http://html.mh-extra.com/html/daikin/rks71kavma/rks71kavma_removal-procedure_2459865022.webp)
Removal of PCBs
Si001167
20
Removal Procedure
5
Unfasten the hook on
the right.
6
Open the terminal
board.
7
Disconnect the
harnesses.
Pull out the relay
connector for standby
electricity saving from
the terminal board.
1: Black
2: White
3: Red
L1: Black
L2: Brown
N1: White
N2: Blue
8
Disconnect the 2
harnesses for the
reactor [HR1] [HR2].
[HR1] : White
[HR2] : Blue
The harness for [HR2] has a
ferrite core.
Step
Procedure
Points
(R5283)
(R13543)
(R13542)
N2
N1
L1
3
2
1
L2
Relay
connector for
standby
electricity
saving
(R5286)
[HR2]
Ferrite core
[HR1]