Specifications

TECHNICAL SPECIFICATIONS

OUTDOOR UNITS

RKS50BVMB9

RKS60BVMB9

RKS71BVMB9

DIMENSIONS

Unit

H

mm

735

W

mm

825

D

mm

300

WEIGHT

kg

49

53

55

COLOUR

Unit

Ivory white

SOUND LEVEL

Sound pressure (1) (Cooling) high/low

dB(A)

47/*

49/*

52/*

Sound power (2) (Cooling)

high

dB(A)

63

64

66

FAN

Air flow rate (Cooling)

high/low

m

3

/min

47.7/44.1

47.6/44.1

51.5/41.5

Speed (Cooling)

high

rpm

700

730

790

low

rpm

650

680

650

Model

Propeller fan

Motor output

W

53

HEAT EXCHANGER

Type

Waffle fin,

J

8 Hi-XA tube

Rows x stages x fin pitch

mm

1 x 32 x 1.6

2 x 32 x 1.8

REFRIGERANT CIRCUIT

Refrigerant type

R-410A

Refrigerant charge

kg

1.20

1.70

1.70

Maximum allowable distance between indoor

and outdoor

m

30

Maximum allowable level difference

m

20

Refrigerant control

-

COMPRESSOR

Type

Hermetically sealed swing type

Model

2YC32HXD

2YC45BXD

Motor output

1,500

1,500

1,900

Oil type

FVC50K

Oil charge volume

!

0.65

0.65

0.75

PIPING CONNECTIONS

liquid

mm

φ

6.4

gas

mm

φ

12.7

φ

15.9

drain

mm

φ

18.0

INSULATION MATERIAL

Heat insulation

Both liquid and gas pipes

* This information was not available at the time of publication.

ELECTRICAL SPECIFICATIONS

OUTDOOR UNITS

RKS50BVMB9

RKS60BVMB9

RKS71BVMB9

CURRENT

Nominal running current

cooling

A

6.82

9.12

10.90

Max. running current

cooling

A

Please refer to electrical data

Starting current

cooling

A

7.3

9.3

11.1

OUTDOOR UNITS

RKS50BVMB9

RKS60BVMB9

RKS71BVMB9

POWER SUPPLY

VM

VM

VM

NOMINAL DISTRIBUTION

SYSTEM VOLTAGE

Phase

1

1

1

Frequency

Hz

50

50

50

Voltage

V

230

230

230

3D040781A

3D040782A

3D040783A

NOTES

1

The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and

acoustic environment. For measuring conditions: please refer to item 8 of this chapter.

2

The sound power level is an absolute value indicating the ’’power’’ which a sound source generates.

Pair Application, Inverter Controlled Unit

R-410A

RKS50-60-71BVMB9

1

2

3

Split - Sky Air

Outdoor Units

Summary of Contents for RKS50BVMB9

Page 1: ...RKS B Pair Application Inverter Controlled Unit technical data Split Sky Air air conditioning systems...

Page 2: ...the quality of the environment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard ISO9001 pertains to quality assurance regarding design de...

Page 3: ...onal drawings 11 5 Operation range 12 6 Piping diagrams 13 7 Wiring diagrams 14 8 Sound level 15 Sound level data Sound pressure spectrum 9 Accessories 17 Standard accessories Optional accessories 10...

Page 4: ...e mounted easily on a roof or terrace or simply placed against an outside wall They are fitted with a swing compressor renowned for its low noise and high energy efficiency Pair Application Inverter C...

Page 5: ...rge volume 0 65 0 65 0 75 PIPING CONNECTIONS liquid mm 6 4 gas mm 12 7 15 9 drain mm 18 0 INSULATION MATERIAL Heat insulation Both liquid and gas pipes This information was not available at the time o...

Page 6: ...0 54 3D040876 RKS FFQ50B RKS FFQ60B Indoor unit Outdoor unit Power supply Compressor OFM IFM Hz Volts Voltage range MCA MFA RHz RLA W FLA W FLA FFQ50BV1B RKS50BVMB9 50 230 MAX 50Hz 253V MIN 50Hz 207V...

Page 7: ...ad Amps W Rated motor output W NOTES 1 RLA is based on the following conditions Indoor temp 27 CDB 19 0 CWB Outdoor temp 35 CDB 2 Maximum allowable voltage unbalance between phases is 2 3 Select wire...

Page 8: ...4 46 2 43 6 87 4 42 2 49 6 72 4 35 2 59 18 0 25 7 47 4 67 2 23 7 32 4 60 2 33 7 17 4 53 2 42 7 11 4 50 2 46 7 02 4 46 2 52 6 87 4 39 2 61 19 0 27 7 55 4 68 2 25 7 40 4 61 2 34 7 25 4 54 2 44 7 19 4 52...

Page 9: ...09 3 47 1 87 4 94 3 40 1 96 3D041022 RKS FFQ60B Cooling capacity 230V 50Hz AFR 15 0 BF 0 11 Indoor Outdoor temperature C EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI...

Page 10: ...10 5 8 4 4 2 13 5 7 4 4 2 19 5 6 4 3 2 29 22 0 30 0 6 4 4 6 1 95 6 2 4 6 2 04 6 1 4 5 2 14 6 0 4 5 2 17 5 9 4 4 2 23 5 8 4 3 2 33 24 0 32 0 6 5 4 7 1 97 6 4 4 6 2 07 6 2 4 5 2 16 6 2 4 5 2 20 6 1 4 4...

Page 11: ...11 5 32 3 93 2 21 18 0 25 6 07 4 24 1 85 5 92 4 17 1 95 5 77 4 10 2 04 5 71 4 07 2 08 5 62 4 03 2 14 5 47 3 96 2 23 19 0 27 6 15 4 26 1 87 6 00 4 19 1 96 5 85 4 12 2 06 5 79 4 09 2 09 5 70 4 05 2 15 5...

Page 12: ...19 0 27 0 6 2 4 7 1 91 6 0 4 6 2 00 5 9 4 6 2 10 5 8 4 5 2 13 5 7 4 5 2 19 5 6 4 4 2 29 22 0 30 0 6 4 4 8 1 95 6 2 4 7 2 04 6 1 4 6 2 14 6 0 4 6 2 17 5 9 4 6 2 23 5 8 4 5 2 33 24 0 32 0 6 5 4 8 1 97 6...

Page 13: ...or bolts M8 or M10 Name plate Terminal strip with earth terminal Wiring inlet Gas stop valve J B CuT Liquid stop valve J A CuT Service port Outdoor air thermistor Brand name label In case of removing...

Page 14: ...ength 7 5 m 2 Level difference 0 m 3 Air flow rate high Possibility to extend the operation range down to 15 C by turning on the switch on the outdoor unit PCB In this case the unit will stop operatio...

Page 15: ...ed valve Muffler with filter Filter Outdoor unit 3D037836A RKS60 71B Outdoor temperature thermistor Heat exchanger Propeller fan Capillary tube 1 Liquid stop valve Field piping Field piping Gas stop v...

Page 16: ...p PCB1 PCB2 Printed circuit board L Live N Neutral S1W Forced operation on off switch SW1 S4W Local setting SA1 Surge arrester g Field wiring Indoor Power supply 50Hz 220 240V 60Hz 220 230V Outdoor ou...

Page 17: ...Sound power level cooling 230V 50Hz Measuring location Cooling H L RKS50B 47 63 RKS60B 49 64 RKS71B 52 66 This information was not available at the time of publication Pair Application Inverter Contr...

Page 18: ...earing for continuous noise RKS71B Octave band sound pressure level approximate threshold hearing for continuous noise 3D027650B Octave band center frequency Hz NOTES 1 Operation sound is measured in...

Page 19: ...plied with the outdoor unit 1 9 2 Optional accessories RKS B RKS50BVMB9 RKS60BVMB9 RKS71BVMB9 Air direction adjustment grille KPW945A4 Installation manual Pair Application Inverter Controlled Unit R 4...

Page 20: ...f gravity RKS50 60B 4D042259 The position of foundation bolt RKS71B 4D042258A The position of foundation bolt Pair Application Inverter Controlled Unit R 410A RKS50 60 71BVMB9 1 10 18 Split Sky Air Ou...

Page 21: ...additional refrigerant Failure to do so may result in reduced performance In sites with poor drainage use block bases for outdoor unit Adjust foot height until the unit is leveled Otherwise water lea...

Reviews: