![background image](http://html1.mh-extra.com/html/daikin/rks18jv2s/rks18jv2s_service-manual_4212642009.webp)
Si001274EC
Electrical Box
Removal Procedure
7
5
Pull out the outdoor
temperature thermistor.
6
Remove the 4 screws
of the right side panel.
7
Unfasten the 3 hooks
and remove the right
side panel.
When reassembling, insert
the upper hook and the 2
lower hooks back into place.
Step
Procedure
Points
(R16794)
Outdoor temperature
thermistor
Right side panel
(R18903)
Hook
(R16823)
Hook
(R16824)