Si001170
Removal of Electrical Box / PCB
Removal Procedure
15
2
Cut the clamp.
When reassembling, fix the
outdoor heat exchanger
lead wire and the harness of
the electronic expansion
valve with a clamp.
3
Pull out the outdoor
heat exchanger
thermistor.
4
Remove the thermistor
ASSY.
Step
Procedure
Points
(R14896)
Outdoor heat exchanger thermistor
(R14897)
(R14898)