EDUS041111_a
Installation Manual
Room Air Conditioners K-Series
49
7
2.
Boring a wall hole and installing wall embedded pipe
• For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent possible
heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of 2-9/16 inch (65mm) in the wall so it has a
down slope toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
3.
Installing indoor unit
• In the case of bending or curing refrigerant pipes, keep the following
precautions in mind.
Abnormal sound may be generated if improper work is conducted.
1) Do not strongly press the refrigerant pipes onto the bottom frame.
2) Do not strongly press the refrigerant pipes on the front grille, either.
3-1. Right-side, right-back, or right-bottom piping
1) Attach the drain hose to the underside of the refrigerant pipes with
an adhesive vinyl tape.
2) Wrap the refrigerant pipes and drain hose together with insulation
tape.
3) Pass the drain hose and refrigerant pipes through the wall hole, then
set the indoor unit on the mounting plate hooks by using the
markings at the top of the indoor unit as a guide.
4) Open the front panel, then open the service lid.
5) Pass the inter-unit wire from the outdoor unit through the feed-
through wall hole and then through the back of the indoor unit.
Pull them through the front side. Bend the ends of tie wires
upward for easier work in advance. (If the inter-unit wire ends
are to be stripped first, bundle wire ends with adhesive tape.)
6) Press the bottom frame of the indoor unit with both hands to set
it on the mounting plate hooks. Make sure the wires do not
catch on the edge of the indoor unit.
Inside
Outside
Caulking
Wall embedded pipe
(field supply)
Wall hole cover
(field supply)
Wall embedded pipe
(field supply)
φ
2-9/16”
(
φ
65mm)
1)
2)
Right-bottom
piping
Right-side piping
Right-back piping
Bind coolant pipe
and drain hose
together with
insulating tape.
Remove pipe port cover
here for right-side piping.
Remove pipe port cover
here for right-bottom piping.
Mounting plate
A
When stripping the
ends of inter-unit wire in
advance, bind right ends
of wires with insulating tape.
Hang indoor unit’s hook here.
Inter-unit wire
Mounting plate
A
Summary of Contents for RKN09KEVJU
Page 1: ...EDUS041111_a K Series Cooling Only Heat Pump SEER 18 Models ...
Page 59: ...Installation Manual EDUS041111_a 58 Room Air Conditioners K Series Accessories ...
Page 60: ...EDUS041111_a Installation Manual Room Air Conditioners K Series 59 ...
Page 61: ...Installation Manual EDUS041111_a 60 Room Air Conditioners K Series ...
Page 62: ...EDUS041111_a Installation Manual Room Air Conditioners K Series 61 ...
Page 63: ...Installation Manual EDUS041111_a 62 Room Air Conditioners K Series ...
Page 64: ...EDUS041111_a Installation Manual Room Air Conditioners K Series 63 ...
Page 65: ...Installation Manual EDUS041111_a 64 Room Air Conditioners K Series ...
Page 66: ...EDUS041111_a Installation Manual Room Air Conditioners K Series 65 ...
Page 67: ...Installation Manual EDUS041111_a 66 Room Air Conditioners K Series ...
Page 68: ...EDUS041111_a Installation Manual Room Air Conditioners K Series 67 3P276866 2 ...
Page 83: ...Installation Manual EDUS041111_a 82 Room Air Conditioners K Series ...
Page 88: ...EDUS041111_a Installation Manual Room Air Conditioners K Series 87 ...
Page 95: ...Operation Manual EDUS041111_a 94 Room Air Conditioners K Series ...
Page 96: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 95 ...
Page 97: ...Operation Manual EDUS041111_a 96 Room Air Conditioners K Series ...
Page 98: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 97 ...
Page 99: ...Operation Manual EDUS041111_a 98 Room Air Conditioners K Series ...
Page 100: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 99 ...
Page 101: ...Operation Manual EDUS041111_a 100 Room Air Conditioners K Series ...
Page 102: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 101 14 115 14 115 ...
Page 103: ...Operation Manual EDUS041111_a 102 Room Air Conditioners K Series ...
Page 104: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 103 ...
Page 105: ...Operation Manual EDUS041111_a 104 Room Air Conditioners K Series ...
Page 106: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 105 ...
Page 107: ...Operation Manual EDUS041111_a 106 Room Air Conditioners K Series ...
Page 108: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 107 ...
Page 109: ...Operation Manual EDUS041111_a 108 Room Air Conditioners K Series ...
Page 110: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 109 ...
Page 111: ...Operation Manual EDUS041111_a 110 Room Air Conditioners K Series ...
Page 112: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 111 ...
Page 113: ...Operation Manual EDUS041111_a 112 Room Air Conditioners K Series ...
Page 114: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 113 ...
Page 115: ...Operation Manual EDUS041111_a 114 Room Air Conditioners K Series ...
Page 116: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 115 ...
Page 117: ...Operation Manual EDUS041111_a 116 Room Air Conditioners K Series ...
Page 118: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 117 ...
Page 119: ...Operation Manual EDUS041111_a 118 Room Air Conditioners K Series ...
Page 120: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 119 3P272441 1 ...
Page 124: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 123 ...
Page 125: ...Operation Manual EDUS041111_a 124 Room Air Conditioners K Series ...
Page 126: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 125 ...
Page 127: ...Operation Manual EDUS041111_a 126 Room Air Conditioners K Series ...
Page 128: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 127 ...
Page 129: ...Operation Manual EDUS041111_a 128 Room Air Conditioners K Series ...
Page 130: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 129 ...
Page 131: ...Operation Manual EDUS041111_a 130 Room Air Conditioners K Series 14 115 F 14 115 F ...
Page 132: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 131 ...
Page 133: ...Operation Manual EDUS041111_a 132 Room Air Conditioners K Series ...
Page 134: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 133 ...
Page 135: ...Operation Manual EDUS041111_a 134 Room Air Conditioners K Series ...
Page 136: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 135 ...
Page 138: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 137 ...
Page 139: ...Operation Manual EDUS041111_a 138 Room Air Conditioners K Series ...
Page 140: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 139 ...
Page 141: ...Operation Manual EDUS041111_a 140 Room Air Conditioners K Series ...
Page 142: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 141 ...
Page 143: ...Operation Manual EDUS041111_a 142 Room Air Conditioners K Series ...
Page 144: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 143 ...
Page 145: ...Operation Manual EDUS041111_a 144 Room Air Conditioners K Series ...
Page 146: ...EDUS041111_a Operation Manual Room Air Conditioners K Series 145 ...
Page 147: ...Operation Manual EDUS041111_a 146 Room Air Conditioners K Series 3P276856 2 ...
Page 168: ...EDUS041111_a Optional Accessories Room Air Conditioners K Series 167 ...
Page 169: ...Optional Accessories EDUS041111_a 168 Room Air Conditioners K Series ...
Page 170: ...EDUS041111_a Optional Accessories Room Air Conditioners K Series 169 3P248024 2 ...
Page 172: ...EDUS041111_a Optional Accessories Room Air Conditioners K Series 171 3P248024 1A ...
Page 177: ...Optional Accessories EDUS041111_a 176 Room Air Conditioners K Series ...