![background image](http://html1.mh-extra.com/html/daikin/rkm50prv16/rkm50prv16_service-manual_2459840021.webp)
Si001405EB
Compressor
Removal Procedure
19
4
5
6
7
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
Remove the 3 nuts of
the compressor.
Lift up the compressor
and remove it.
Step
Procedure
Points
(R23693)
Compressor
Nut
Brazed part of the
suction side pipe
Brazed part of the
discharge side pipe