![Daikin RKM50PRV16 Service Manual Download Page 12](http://html1.mh-extra.com/html/daikin/rkm50prv16/rkm50prv16_service-manual_2459840012.webp)
PCBs
Si001405EB
10
Removal Procedure
4. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the screw, and
then the electrical box
cover.
2
3
Disconnect the 3
connectors from the
terminal board.
Remove the screw and
release the earth/
ground wire (upper).
4
Cut the 2 clamps.
Electrical box cover
(R20235)
Connector
(R23794)
Earth/ground wire (upper)
screw
(R23817)
HN1 (white)
HL1 (black)
S (red)
Clamp