![background image](http://html1.mh-extra.com/html/daikin/rkc18qv2s/rkc18qv2s_service-manual_4702939007.webp)
Si001658EA
Outdoor Fan / Fan Motor
Removal Procedure
5
4
Remove the nut, and
then the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the fan rotor
with the D-cut section of the
motor shaft.
5
6
Remove the screw of
the fan motor fixing
frame.
Unfasten the 2 hooks at
the bottom and remove
the fan motor fixing
frame.
When reassembling, fit the 2
lower hooks into the bottom
frame.
7
Open the 2 hooks and
release the fan motor
lead wire.
8
Remove the 4 screws,
and then the fan motor.
Step
Procedure
Points
Outdoor fan
Nut
D-cut
(R23702)
10 mm
(0.39 inch)
(R18954)
Fan motor fixing frame
(R23703)
(R22574)
Hook
Fan motor lead wire
Back view
(R23704)
Fan motor
Front view