9
Stopping the system
Press the on/off button once again.
The operation lamp goes off and the system
stops operation.
NOTE
• Do not turn off power immediately after the
unit stops.
• The system needs at least 5 minutes for the
residual operation of drain pump.
Turning the power off immediately will cause
water leak or trouble.
EXPLANATION OF HEATING OPERATION
• For general heating operation, it may take longer
to reach the set temperature than in cooling oper-
ation.
We recommend starting the operation which was
used before using timer operation.
• The following operation is performed in order to
prevent the heating capacity from dropping or
cold air from blowing.
Defrost operation
• In heating operation, freezing of the outdoor
unit coil increases. Heating capability
decreases and the system goes into defrost
operation.
• The indoor unit fan stops and the remote
controller displays
“
”.
• After maximum 10 minutes of defrost operation,
the system returns to heating operation again.
Hot start
• In order to prevent cold air from blowing out
of an indoor unit at the start of heating oper-
ation, the indoor fan is automatically
stopped. The display of the remote controller
shows “
”.
NOTE
• The heating capacity drops as the outside
temperature falls. If this happens, use
another heating device together with the
unit. (When using the appliances which pro-
duce open fire together, ventilate a room
constantly.)
Do not place appliances which produce
open fire in places exposed to the air flow
from the unit or under the unit.
• It takes some time for the room to warm up
from the time the unit is started since the unit
uses a hot-air circulatory system to warm
the entire room.
• If the hot air rises to the ceiling, leaving the
area above the floor cold, we recommend
using the circulator (the indoor fan for circu-
lating air). Contact your dealer for details.
5-2 PROGRAM DRY OPERATION
• The function of this operation is to decrease
the humidity in your room with a minimum
temperature decrease.
• The micro computer automatically deter-
mines temperature and fan speed.
• This function is not available if the room tem-
perature is 68°F or lower.
FOR SYSTEMS WITHOUT COOL/HEAT
SELECTOR (Refer to figure 5)
Press the operation mode selector button several
times and select “
” (program dry operation).
Press the on/off button
The operation lamp lights up and the system
starts operation.
Press the air flow direction adjust button. Refer
to the chapter “Adjusting the air flow direction”
for details.
Press the on/off button once again.
The operation lamp goes off and the system
stops operation.
NOTE
• Do not turn off power immediately after the
unit stops, but wait for at least 5 minutes.
• The system needs at least 5 minutes for the
residual operation of drain pump.
Turning the power off immediately will cause
water leak or trouble.
FOR SYSTEMS WITH COOL/HEAT SELECTOR
(Refer to figure 8)
Select cooling operation mode with the COOL/
HEAT selector.
Press the operation mode selector button sev-
eral times and select “
” (program dry
operation).
Press the on/off button
The operation lamp lights up and the system
starts operation.
Press the air flow direction adjust button. Refer
to the chapter “Adjusting the air flow direction”
for details.
Press the on/off button once again.
The operation lamp goes off and the system
stops operation.
6
1
2
3
4