8-11 THE OUTDOOR UNIT FAN DOES NOT 

ROTATE

During operation.

The speed of the fan is controlled in order to opti-
mize product operation.

8-12 THE DISPLAY SHOWS 

This is the case immediately after the main 
power supply switch is turned on and means 
that the remote controller is in normal condi-
tion. This continues for 1 minute.

8-13 THE COMPRESSOR OR FAN IN THE 

OUTDOOR UNIT DOES NOT STOP 

This is to prevent oil and refrigerant from 
remaining in the compressor. The unit will 
stop after 5 to 10 minutes.

8-14 THE INSIDE OF OUTDOOR UNIT IS 

WARM EVEN WHEN THE UNIT HAS 
STOPPED

This is because the crankcase heater is warm-
ing the compressor so that the compressor 
can start smoothly.

8-15 IT STOPS SOMETIMES

The remote controller display reads “U4” and 
“U5” and stops but then restarts after a few 
minutes.

This is because the remote control is intercepting 
noise from electrical appliances other than the air 
conditioner, and this prevents communication 
between the units, causing them to stop.
Operation automatically restarts when the noise 
goes away.

8-16 HOT AIR IS EMITTED EVEN THOUGH 

THE UNIT IS STOPPED

Hot air can be felt when the unit is stopped.

Several different indoor units are being run on the 
same system, so if another unit is running, some 
refrigerant will still flow through the unit.

8-17 DOES NOT COOL VERY WELL

Program dry operation.

Program dry operation is designed to lower the 
room temperature as little as possible.
Refer to page 9.

9. TROUBLE SHOOTING

If one of the following malfunctions occurs, take 
the measures shown below and contact your 
Daikin dealer.

WARNING

Stop operation and shut off the power if any-
thing unusual occurs (burning smells, etc.)

Leaving the unit running under such circum-
stances may cause breakage, electrical shock, or 
fire.
Contact your dealer.

• If a safety device such as a fuse, a breaker or an 

earth leakage breaker frequently actuates;
Measure: Do not turn on the main power switch.

• If the ON/OFF switch does not properly work;

Measure: Turn off the main power switch.

• If water leaks from unit;

Measure: Stop the operation.

• The operation mode selector button does not 

work well.
Turn off the power.

• If the display “

”, the unit number and the 

operation lamp flash and the malfunction code 
appears; 

(Refer to figure 12)

1. Inspection display
2. Indoor unit number in which a malfunction 

occurs

3. Operation lamp
4. Malfunction code

Measure: Notify your Daikin dealer and report the 
malfunction code.

If the system does not properly operate except 
for the above mentioned cases and none of the 
above mentioned malfunctions is evident, inves-
tigate the system according to the following pro-
cedures.
If it is impossible to fix the problem yourself after 
checking all the above items, contact your 
dealer.
Let him know the symptoms, system name, and 
model name.

1. If the system does not operate at all;

• Check if there is a power failure.

Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power supply 
is recovered.

TEST

01_EN_3P161360-3D.fm  Page 14  Thursday, April 13, 2006  9:46 AM

Summary of Contents for REYQ144MTJU

Page 1: ...RXYQ192MTJU REYQ72MTJU REYQ96MTJU REYQ144MTJU REYQ168MTJU REYQ192MTJU Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual should b...

Page 2: ...Figure 1 RXYQ REYQ F NOT AVAILABLE 23 24 Figure 2 Figure 3 F F Figure 4 Figure 5 Figure 6 Figure 7 1 Figure 7 3 Figure 7 2 F F F 00_CV_3P161360 3D fm Page 2 Wednesday April 12 2006 5 25 PM...

Page 3: ...F Figure 8 Figure 9 F F Figure 10 Figure 11 Figure 12 Wall Mounted Multi flow Ceiling Suspended Figure 13 Figure 14 Figure 15 00_CV_3P161360 3D fm Page 3 Wednesday April 12 2006 5 25 PM...

Page 4: ...in the unit or property damage only accidents Keep these warning sheets handy so that you can refer to them if needed Also if this unit is transferred to a new user make sure to hand over this operati...

Page 5: ...er the fins while working around them Do not put a finger or other objects into the air inlet or air outlet The fan is rotating at high speed and will cause injury Do not allow children to play on or...

Page 6: ...r the indoor unit It may cause incomplete combustion or deformation of the unit due to the heat Arrange the drain hose to ensure smooth drainage Incomplete drainage may cause wet ting of the building...

Page 7: ...and or stop time 18 Temperature setting button Use this button for setting the desired tempera ture 19 Filter sign reset button Refer to the operation manual of indoor unit 20 Fan speed control butto...

Page 8: ...tem may control the air flow rate automatically It may take some time to change the air flow rate This is not a malfunction FOR SYSTEMS WITHOUT COOL HEAT SELECTOR Refer to figure 4 Press the operation...

Page 9: ...since the unit uses a hot air circulatory system to warm the entire room If the hot air rises to the ceiling leaving the area above the floor cold we recommend using the circulator the indoor fan for...

Page 10: ...the set time has elapsed Programming the start time The sys tem starts operating after the set time has elapsed The timer can be programmed for a maxi mum of 72 hours The start and the stop time can b...

Page 11: ...CON TROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one indoor unit system Confirm which type of your unit is the follo...

Page 12: ...ion See the operation manual included with the indoor unit for details on how to clean it 8 FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROU BLES 8 1 THE SYSTEM DOES NOT OPERATE The air conditioner doe...

Page 13: ...r to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted 8 8 NOISE OF AIR CONDITIONERS Indoor unit A zeen sound is heard immediately after the power...

Page 14: ...efer to page 9 9 TROUBLE SHOOTING If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer WARNING Stop operation and shut off the power if any thing un...

Page 15: ...r unit manual 3 The system operates but cooling or heating is insufficient Check if air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove any obstacle and make it well ventilate...

Page 16: ...1645 Wallace Drive Suite 110 Carrollton TX 75006 info daikinac com www daikinac com 0605 HT 3P161360 3D EM03A045D 00_CV_3P161360 3D fm Page 4 Wednesday April 12 2006 5 25 PM...

Reviews: