Wiring diagram
9 - 1
Wiring diagram
2TW26326-1B
REQ71-100BV3
A1P
Printed circuit board
BS1
Push button (forced defrost-pump down)
C1R
Capacitor (M1F)
C3R
Capacitor (M1C)
DS1
DIP switch
E1HC
Crankcase heater
F1U
Fuse (T6.3/250V)
HAP
Light emitting diode (service monitor green)
K1M
Magnetic contactor (M1C)
K1R
Magnetic relay (K1M)
K2R
Magnetic relay (Y2S)
K3R
Magnetic relay (E1HC)
K4R
Magnetic relay (Y1S)
K5R,K6R,K7R Magnetic relay (M1F)
M1C
Motor compressor
M1F
Motor fan
PC
Power circuit
Q1DI
Earth leakage breaker (30mA)
Q1M
Thermo switch (M1F)
R1T
Thermistor (air)
R2T
Thermistor (coil)
R3T
Thermistor (discharge pipe)
RC
Signal receiver circuit
S1PH
Pressure switch (high)
S1LP
Pressure switch (low)
SD
Safety devices input
T1A
Current transformer
TC
Signal transmission circuit
X1M,X2M Terminal strip
Y1E
Expansion valve (electronic type)
Y1S
4-way valve
Y2S
Solenoid valve
CT
Current transformer
Indoor
Note:
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g
Field wiring
D
: Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
Switch box
(Outdoor)
Outdoor
ON
OFF
Position of
compressor
terminal
Wire
entrance
Power supply
1
∼
50Hz
230V
2TW26336-1B
REQ71-100BW1
A1P
Printed circuit board
BS1
Push button (forced defrost-pump down)
C1
Capacitor (M1F)
DS1
DIP switch
E1HC
Crankcase heater
F1U, F2U Fuse (T6.3/250V)
HAP
Light emitting diode (service monitor green)
K1M
Magnetic contactor (M1C)
K1R
Magnetic relay (K1M)
K2R
Magnetic relay (Y2S)
K3R
Magnetic relay (E1HC)
K4R
Magnetic relay (Y1S)
K5R,K6R,K7R Magnetic relay (M1F)
M1C
Motor compressor
M1F
Motor fan
PC
Power circuit
Q1DI
Earth leakage breaker (30mA)
Q1M
Thermo switch (M1F)
Q1RP
Phase reverse circuit
R1T
Thermistor (air)
R2T
Thermistor (coil)
R3T
Thermistor (discharge pipe)
RC
Signal receiver circuit
S1HP
Pressure switch (high)
S1LP
Pressure switch (low)
SD
Safety devices input
T1A
Current transformer
TC
Signal transmission circuit
X1M,X2M Terminal strip
Y1E
Expansion valve (electronic type)
Y1S
4-way valve
Y2S
Solenoid valve
CT
Current transformer
Indoor
Note:
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g
Field wiring
D
: Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
Switch box
(Outdoor)
Outdoor
ON
OFF
Position of
compressor
terminal
Wire
entrance
Power supply
3N
∼
50Hz
400V