Operating Procedures
WARNING
FIRE OR EXPLOSION HAZARD
LOCKOUT/TAGOUT all power sources prior to installing the gas furnace.
Failure to follow warnings exactly could result in serious injury, death,
or property damage. Be sure to read and understand the installation,
operation, and service instructions within this manual. Improper installation,
adjustments, alterations, service, or maintenance can cause serious injury,
death or property damage.
—
Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this appliance.
—
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any product that is fueled by or
contains an open flame.
• Do not touch any electrical switch.
• Do not use any telephone in the building.
• Leave the building immediately.
• Immediately call the gas supplier from a remote
telephone and follow the gas supplier’s instructions.
• If you cannot reach the gas supplier, call the local fire
department or 911 .
—
Installation and service must be performed by a
qualified installer, service agency, or gas supplier.
WARNING
RISQUE D’INCEDIE OU D`EXPLOSION
Le non respect des mises en garde pourrait entrainer des blessures graves,
la mort ou des pertes materielles. Prendre soin de lire et de comprendre les
instructions d’installation, de fonctionement et d’entretien contenues dans
ce guide. Une installatoin, un reglage, une modification, une reparation ou
un entretien inapproprie peut entrainer des blessures graves, la mort ou
des pertes materielles.
—
Ne pas entreposer ni utiliser d’essence ou autre
vapeurs ou liquides inflammables a proximite de cet
appareil ou de tout autre appareil .
—
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne tentez pas d’alumer un appareil.
• Ne touchez pas a un interupteur; n’utilisez pas de
telephone dan l’edifice ou vous trouvez.
• Sortez de l’edifice immediatement.
• Appelez immediatement le fournisseurde gas a partir
d’un telephone a l’exterieur de l’edifice. Suivez les
instructions du fournisseur de gaz.
• Si vous ne pouvez joindre le fournisseur de gaz,
appelez les pompiers .
—
L’installation et les reparations doivent etre confiees a
un installatei=ur qualifie ou au fournisseur de gaz.
Set the controller to the lowest setting.
5 .
Turn off all electric power to the appliance.
6 .
This appliance is equipped with an ignition device which
automatically lights the burner. Do NOT try to light the
pilot by hand.
7 .
Open the control access panel.
8. Turn the gas control clockwise to “OFF”.
9 .
Wait five (5) minutes to clear out any gas. Then, smell
for gas, including near the floor. If you smell gas,
STOP!
Follow step “B” in the DANGER label on this page. If you
don’t smell gas, proceed to the next step.
10. Turn the gas control counter-clockwise to “ON”.
11 .
Close the control access panel.
12 .
Turn on all electric power to the appliance.
13 .
Set controller to full heat.
14 . Verify manifold pressure and rate .
15 .
If the appliance will not operate, refer to “Turning Off Gas
to the Appliance”, and call a qualified service technician.
Turning OFF Gas to the Appliance
1 .
Set the controller to the lowest setting.
2 .
Turn OFF all electrical power to the appliance if service
is to be performed .
3 .
Open the control access panel.
4 .
Turn gas control knob clockwise to “OFF”. Do not force.
5 .
Close the control access panel.
Service
The furnace DDC controller has diagnostic information for
troubleshooting the furnace operation. The ignition control
module has a LED light that will flash when an abnormal
.
Maintenance
Planned maintenance is the best way to avoid unnecessary
expense and inconvenience. Have this system inspected
at regular intervals by a trained and experienced service
technician. The following service intervals are typical for
average situations but will have to be adjusted to suit your
particular circumstances.
Fuel pressure settings and control settings should be made
only by persons thoroughly experienced with the burner and
control system, and must not be tampered with by persons
without such experience.
Always replace covers on burner controls and boxes as the
electrical contacts are sensitive to dust and dirt. Perform
maintenance of controls, gas valves, and other components in
accordance with instructions in the manufacturer’s bulletins.
IM-1125-13 • REBEL ROOFTOPS
60
www.DaikinApplied.com
Optional Gas Heat