Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the User's Manual carefully before using this product. The User's Manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install 

the outdoor unit close to the sea shore, contact your local distributor.

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of August 2012 but subject to change without notice.

Si011194

08/2012 AK.B

Summary of Contents for RE60KV1

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 6 0 kW Class Outdoor Unit Non Inverter Pair Type Si011194...

Page 2: ...Service Manual Removal Procedure Outdoor Unit Applicable Models zCooling Only RE60KV1 RE60KV14 RE60LV16 RE60LV1V RE60MV16...

Page 3: ...Outer Panels 2 2 Removal of Outdoor Fan Fan Motor 7 3 Removal of Sound Blanket 10 4 Removal of Electrical Component ASSY 11 5 Removal of Capillary Tube 13 6 Removal of Compressor ASSY 14 Note The ill...

Page 4: ...inutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the 4 screws and remove the top panel Take care not to cut your finger by the fins of the o...

Page 5: ...ls Removal Procedure 3 3 Remove the 6 screws of the front panel 4 Unfasten the center hooks in the order of 1 to 2 5 Lift the left side of the front panel and unfasten the 3 hooks Step Procedure Point...

Page 6: ...94 4 Removal Procedure 6 Unfasten the hook on the right side and remove the front panel 7 Remove the screw and remove the stop valve cover The stop valve cover has 6 hooks Step Procedure Points R5398...

Page 7: ...Panels Removal Procedure 5 8 Remove the 4 screws of the right side panel 9 Unfasten the hook at the rear side 10 Lift up and remove the right side panel Step Procedure Points R16851 Right side panel...

Page 8: ...Removal of Outer Panels Si011194 6 Removal Procedure When reassembling fit the 2 lower hooks Step Procedure Points Hook R5410...

Page 9: ...or more after turning off all power supplies before disassembling work Step Procedure Points 1 Disconnect the relay connector for the fan motor 2 Remove the 2 screws of the fan motor fixing plate 3 L...

Page 10: ...s Put the fan motor lead wire through the back of the fan motor when reassembling so as not to be entangled with the outdoor fan 5 Remove the nut and remove the outdoor fan Nut size M6 Align the mark...

Page 11: ...Si011194 Removal of Outdoor Fan Fan Motor Removal Procedure 9 6 Remove the 4 screws and remove the fan motor Step Procedure Points R5406...

Page 12: ...Removal of Sound Blanket Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the sound blanket body S...

Page 13: ...turning off all power supplies before disassembling work Step Procedure Points 1 Remove the terminal cover 2 Disconnect the compressor lead wires Be careful so as not to burn the compressor terminals...

Page 14: ...ponent ASSY and unfasten the guide for the partition plate Remove the electrical component ASSY Compressor lead wire S yellow C blue R red Step Procedure Points R16238 Screw Electrical component ASSY...

Page 15: ...arge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoration 1 Restore the piping by non oxidation brazing 2 Avoid excessive heating Keep below 120...

Page 16: ...for restoration 1 Restore the piping by non oxidation brazing 2 Avoid excessive heating Keep below 120 C In case of difficulty with gas brazing machine 1 Disconnect the brazed part where is easy to di...

Page 17: ...Revision History Month Year Version Revised contents 08 2012 Si011194 First edition...

Page 18: ...ries supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acce...