background image

REMOVAL

PROCEDURE

S E R V I C E   M A N U A L

6.0 kW Class

Outdoor Unit

Non-Inverter

Pair Type

Si011194

Summary of Contents for RE60KV1

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 6 0 kW Class Outdoor Unit Non Inverter Pair Type Si011194...

Page 2: ...Service Manual Removal Procedure Outdoor Unit Applicable Models zCooling Only RE60KV1 RE60KV14 RE60LV16 RE60LV1V RE60MV16...

Page 3: ...Outer Panels 2 2 Removal of Outdoor Fan Fan Motor 7 3 Removal of Sound Blanket 10 4 Removal of Electrical Component ASSY 11 5 Removal of Capillary Tube 13 6 Removal of Compressor ASSY 14 Note The ill...

Page 4: ...inutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the 4 screws and remove the top panel Take care not to cut your finger by the fins of the o...

Page 5: ...ls Removal Procedure 3 3 Remove the 6 screws of the front panel 4 Unfasten the center hooks in the order of 1 to 2 5 Lift the left side of the front panel and unfasten the 3 hooks Step Procedure Point...

Page 6: ...94 4 Removal Procedure 6 Unfasten the hook on the right side and remove the front panel 7 Remove the screw and remove the stop valve cover The stop valve cover has 6 hooks Step Procedure Points R5398...

Page 7: ...Panels Removal Procedure 5 8 Remove the 4 screws of the right side panel 9 Unfasten the hook at the rear side 10 Lift up and remove the right side panel Step Procedure Points R16851 Right side panel...

Page 8: ...Removal of Outer Panels Si011194 6 Removal Procedure When reassembling fit the 2 lower hooks Step Procedure Points Hook R5410...

Page 9: ...or more after turning off all power supplies before disassembling work Step Procedure Points 1 Disconnect the relay connector for the fan motor 2 Remove the 2 screws of the fan motor fixing plate 3 L...

Page 10: ...s Put the fan motor lead wire through the back of the fan motor when reassembling so as not to be entangled with the outdoor fan 5 Remove the nut and remove the outdoor fan Nut size M6 Align the mark...

Page 11: ...Si011194 Removal of Outdoor Fan Fan Motor Removal Procedure 9 6 Remove the 4 screws and remove the fan motor Step Procedure Points R5406...

Page 12: ...Removal of Sound Blanket Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the sound blanket body S...

Page 13: ...turning off all power supplies before disassembling work Step Procedure Points 1 Remove the terminal cover 2 Disconnect the compressor lead wires Be careful so as not to burn the compressor terminals...

Page 14: ...ponent ASSY and unfasten the guide for the partition plate Remove the electrical component ASSY Compressor lead wire S yellow C blue R red Step Procedure Points R16238 Screw Electrical component ASSY...

Page 15: ...arge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoration 1 Restore the piping by non oxidation brazing 2 Avoid excessive heating Keep below 120...

Page 16: ...for restoration 1 Restore the piping by non oxidation brazing 2 Avoid excessive heating Keep below 120 C In case of difficulty with gas brazing machine 1 Disconnect the brazed part where is easy to di...

Page 17: ...Revision History Month Year Version Revised contents 08 2012 Si011194 First edition...

Page 18: ...ries supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acce...

Reviews: