ELECTRICAL CONNECTION
FDM20JEV1K - RD20JEV1K
FDM25JEV1K - RD25JEV1K
IMPORTANT:
* These values are for information only, they should be checked and selected to comply with the local and/or national
codes and regulations. They are also subjected to the type of installation and size of conductors.
** The appropriate voltage range should be checked with data label on the unit.
Model
Indoor
FDM20JEV1K
FDM25JEV1K
Outdoor
RD20JEV1K
RD25JEV1K
Voltage range**
Indoor
220-240V/1Ph/50Hz +
!
Outdoor
220-240V/1Ph/50Hz +
!
Power supply cable size*
mm
2
Number of conductors
2.5
3
2.5
3
Interconnection cable size*
mm
2
Number of conductors
1.0
4
1.0
4
Recommended time delay fuse*
A
20
25
COMP
L1
N1
L
Power Supply
Cable
Outdoor unit
Terminal Block
COMP
Interconnection
cable
Indoor unit
Terminal Block
L
N
N
N
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
Model
Indoor
FDM30JEV1K
Outdoor
RD30JEV1K
Voltage range**
Indoor
220-240V/1Ph/50Hz+
!
Outdoor
220-240V/1Ph/50Hz+
!
Power supply cable size*
mm
2
Number of conductors
4
3
Interconnection cable size*
mm
2
Number of conductors
2.5
4
Recommended time delay fuse*
A
30
Power Supply Cable
Interconnection cable
Outdoor unit
Terminal Block
Indoor unit
Terminal Block
FDM30JEV1K - RD30JEV1K
COMP
L
L
N
N
COMP
L
N
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
!
L
N