![Daikin Quaternity FTXG09HVJU Operation Manual Download Page 10](http://html1.mh-extra.com/html/daikin/quaternity-ftxg09hvju/quaternity-ftxg09hvju_operation-manual_2460275010.webp)
9
English
To set the clock
* Time cannot be set during unit operation.
1.
Press
.
Do not hold the button.
is displayed.
blinks.
2.
Press
.
•
Holding the button changes the time faster.
3.
Press
.
blinks.
is displayed.
•
Setting is complete.
NOTE
If other messages than time appear on the display with the step
1
operation, do not operate the button for about 60 seconds. The display will return to normal.
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save
energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling
(heating) effect.
• Clogged air filters cause inefficient operation and waste energy.
Periodically clean the filter.
Recommended temperature setting
For cooling : 79°F – 82°F (26°C – 28°C)
For heating : 68°F – 72°F (20°C – 22°C)
Notes on the operating conditions
• The air conditioner always consumes a small amount of electricity
even while it is not operating.
• If you are not going to use the air conditioner for a long period, for
example in spring or autumn, turn the breaker off.
• When the outdoor temperature is below 5°F (–15°C), turn on the
breaker more than 1 hour before starting the operation.
(This is to warm up the compressor.)
• Running the unit under conditions not listed below may cause the
safety device to activate, stopping the unit. Also, condensation may
form on the indoor unit and drip. (DRY/COOLING operation)
MODE
Operating conditions
COOLING
Outdoor temperature : 14 to 109°F (–10 to 43°C)
Indoor temperature : 64 to 90°F (18 to 32°C)
Indoor humidity : 80% max.
HEATING
Outdoor temperature : –4 to 75°F (–20 to 24°C)
Indoor temperature : 50 to 86°F (10 to 30°C)
Indoor humidity : 70% max.
DRY
Outdoor temperature : 50 to 108°F (10 to 42°C)
Indoor temperature : 64 to 86°F (18 to 30°C)
Indoor humidity : 80% max.
01_EN_3P226009-1A.indd 9