3
|
Components
Service manual
182
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
Pins
Measured resistance (Ω)
1-2
353.4~406.6
1-3
1-4
1-5
2-3
706.8~813.2
2-4
2-5
3-4
3-5
4-5
Swing raster motor resistance
measurements are correct?
Action
Yes
Replace the swing raster motor wiring
harness, see
No
Replace the swing raster motor, see
182].
3.18.2 Repair procedures
To remove the swing raster motor
Class 20~42 indoor unit
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
151].
1
Remove the switch box, see
2
Put a small drain pan (or container) under the drain hose.
3
Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
a
b