1

1.

TEMPERATURE (Seven Segments)

To indicate the ambient temperature set by the user.

2.

MODE

To indicate the selected operating mode: HEAT & DRY / COOL / FAN
(LED green / yellow / red).

3.

VENTILATION SPEED

To indicate the selected ventilation speed: LOW / MED / HIGH

For U1-SB125 only have single speed: HIGH.

4.

AUTO SELECTION

Automatic selection for speed, whereby the speed is automatically adjusted according to the room temperature.

5.

FAN AND VENTILATION MODE

Press the fan button to set the desired selection.

6.

OPERATION SELECTION MODE

Press the mode button to select the type of operation mode.

Cooling unit: COOL, DRY, FAN.

Heat pump unit: AUTO, COOL, DRY, FAN, HEAT.

The AUTO mode is unavailable for chilled water (CW) 2 pipe system.
It is available for Chilled Water (CW) 4 pipe system.

7.

TEMPERATURE SETTING

Set the desired temperature.

Press 

 or 

 button to increase or decrease the set temperature. The setting range is between 16°C to 30°C (60°F to

80°F).

8.

TIMER SWITCH SETTING

Press the set button to activate the switch timer of the air conditioner unit (the setting range is between 1 to 10 hours).
The unit will be at ON or OFF state in function of operating mode.

9.

“SLEEP ” FUNCTION

Press the sleep button to select the sleep function. This function cannot be selected if the air conditioner unit is
operating under FAN mode only or dry mode. For SLEEP function operating under COOL mode, the setting
temperature increases to 0.5°C after 30 minutes, 1°C after 1 hour and 2°C after 2 hours.

10.

“ON/OFF” SWITCH

Press once, the air conditioner unit starts.

Press again, the air conditioner unit stops.

11.

IR RECEIVER

12.

AUTOMATIC AIR SWING (OPTIONAL)

Press the 

SWING

 button to activate the automatic air swing function.

To distribute the air to a specific direction, press the button and wait until the louver move to the desired direction
and press the 

SWING

 button once again.

OPERATING INSTRUCTION

ENGLISH

Error

Seven Segments

Room Sensor missing/Short

E1 blinking

Indoor coil sensor missing/Short

E2 blinking

Outdoor coil sensor missing/Short

E3 blinking

Compressor overload

E4 blinking

Outdoor abnormal compressor

E5 blinking

overload trip or gas leak

Pump fault

E6 blinking

NOTE:

Function 3, 4, 5, 9, 12 are not applicable for Roof Top models.

Function 6 (Dry Mode) is not applicable for Roof Top models.

Function 12 (Automatic Air Swing) mode is not applicable for ducted models.

OM-SLM-0906(1)-Daikin(Asean)

2/11/09, 3:48 PM

1