Operation lamp

• Turbo lamp (orange)
• Anti-pollen lamp (green)
• Sleep mode lamp (green)

Filter lamp (orange)

The fi lter lamp lights up when the pleated fi lter 
needs replacement and starts blinking when a 
certain time has elapsed after the lamp turned on.

 

Page 21.

UNIT lamp (orange)

• “UNIT1”

  This lamp lights up when it is time to clean the plasma 

ioniser.

• “UNIT2”

  This lamp lights up when it is time to clean the streamer unit.

 

Page 19, 20.

• Even when the lamp does not light up, clean the streamer unit once 

every 3 months.

Odour sensor lamp

The three-colour indicators (green, yellow, red) indicate the odour level.

• When the air is clean, the green lamp lights up.

 

In the following case, only the green lamp lights up for the initial 

1 minute. The initial level of odour is recorded as the standard 

level.

1)  Operation directly after attaching the front panel and UNIT1
2)  Operation directly after reconnecting the power plug

 

If the odour level remains constant without intensifying or weakening, 
the odour sensor may not detect even strong odours.

 

The odour sensor may not detect certain types of odours such as pet 
odours other than ammonia, garlic, etc.

 

Even if only the green lamp lights up, you may notice some smell 
because the sensitivity is different among individuals.
If bothered by odours, set airfl ow manual operation and run the unit at a 
higher airfl ow rate.

Odour

Weak

Strong

Green

Green

Yellow

Green

Yellow

Red

Lights up

Detectable

Cigarette odours, cooking odours, pet and toilet odours, raw waste odours, mildew odours, sprays, 
alcohol

Sometimes detectable

Sudden changes in temperature and humidity, odourless gases such as carbon monoxide, steam, oil 
vapours, gas from combustion appliances

ON / OFF / Mode 

change button

The operation mode changes each time 
the button is pressed.

 

Page 14.

Filter reset button

The fi lter lamp is turned off by pressing 
the button for 5 seconds after the pleated 
fi lter is replaced with a new one.

 

Page 21.

OFF TIMER lamp (yellow)

01_EN_3P276413-4F.indd   8

8/1/2012   11:29:31 AM

Summary of Contents for mc70mvm6

Page 1: ...Air Puri er OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70MVM6...

Page 2: ...hat readily settles because of its large particle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes adsorbed odour The decomposition cycle that main...

Page 3: ...g environment These cases are also not operational issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operati...

Page 4: ...o electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by humidity or other factors may lead to fir...

Page 5: ...r supply cord and pull to disconnect the unit Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from...

Page 6: ...the unit where pets are kept be careful that pets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconne...

Page 7: ...ores the accessory remote controller when not in use Remote controller Power plug Power supply cord Holds 4 replacement pleated filters Page 9 Filter container Front panel Ventilation fan Ionised wire...

Page 8: ...nness level 1 Operation directly after attaching the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the sett...

Page 9: ...ter reconnecting the power plug If the odour level remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types o...

Page 10: ...How to attach the pleated filter Make sure to attach the pleated filter before starting operation 1 Remove the front panel Push the 2 clips right and left and pull the front panel upward and remove i...

Page 11: ...the deodorising catalyst unit by the handles fit the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deod...

Page 12: ...ontrols unevenness in the room temperature while cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside...

Page 13: ...a battery is swallowed make sure to contact a doctor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combu...

Page 14: ...gage the childproof lock You can release the childproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds...

Page 15: ...automatically resume operation when the power plug is connected next time Auto fan operation The airflow rate is automatically selected from Quiet Low Standard or High according to the uncleanness le...

Page 16: ...it because the UNIT1 lamp may light up if any water drops remain on the prefilter Use a vacuum cleaner to remove the dust Soak in lukewarm water or water About 1 hour Dry throughly after soaking Care...

Page 17: ...with a cloth moistened with neutral detergent Do not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odou...

Page 18: ...tions into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising cataly...

Page 19: ...me Pinching the sets of knobs on the right and left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green...

Page 20: ...soft brush etc Wear rubber gloves Wear rubber gloves Cloth Cotton swab Wipe 1 Ionising frame 2 Ionised wire For details Rub Wear rubber gloves Cloth Brush Rinse in running water and drain Dry in a we...

Page 21: ...ge or rust If the needles inside UNIT2 are deformed deodorising capacity diminishes Wear rubber gloves Cloth Cotton swab Wipe 3 Streamer unit For details If detergent remains on UNIT1 or UNIT2 the UNI...

Page 22: ...n the upper part of the front panel for 5 seconds The filter lamp goes off with a short beep sound Filter reset button Even if the pleated filter is replaced the filter lamp does not go off unless you...

Page 23: ...ds reconnect the power plug and try the operation again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reac...

Page 24: ...ion Can the deodorising catalyst unit be washed with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it wi...

Page 25: ...e is odour the green lamp remains lit Is a large amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of th...

Page 26: ...en if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off Page 21 Other There is a burn mark on the metal part of UNIT2 This is a mark...

Page 27: ...26 MEMO...

Page 28: ...3P276413 4F M11B332B 1208 HT Two dimensional bar code is a code for manufacturing...

Reviews: