Daikin MC707PVM Operation Manual Download Page 6

5

 / English

Preparation Before Operation

„

Remote controller setup

1. Remote controller 

preparations

• Battery is already set in the remote 

controller but the remote controller 
cannot be used as is without first 
preparing it.
Use the remote controller after 
pulling out the clear sheet from the 
battery cover.

2. Remote controller storage

• When the remote controller is not 

being used, you can store it in the 
remote controller storage slot.

3. Using the remote controller

• Point the transmitter of the remote 

controller towards the receiver of 
the main unit.
If an obstruction to the signal, such 
as a curtain, exists, the remote 
controller will not operate.

• The distance from which the 

remote controller can transmit is 
approximately 6m.

4. Battery replacement

1) Open the cover on the rear of the 

remote controller towards the 
arrow.

2) Replace the battery with CR2025 

battery.
(Be sure to set the battery with the 
+ side of the cover as shown in the 
figure.)

3) Close the cover to its original 

position.

NOTE

Store the batteries where babies and children cannot reach them.
If, by chance, a battery is swallowed, be sure to contact a doctor 
immediately.

When discarding batteries, cover the terminals of the batteries with 
tape.
If mixed with other metal or batteries, heat, explosion or combustion 
may occur.

ATTENTION

Battery

The included coin type battery is prepared for initial use.
They will be consumed within 1 year from the manufacturing date of 
the air purifier.

A replacement target is approximately 1 year but if the reception 
becomes difficult, replace the batteries with new coin type battery 
CR2025.

Coin type battery close to the “recommended usage period” may 
need to be replaced soon.

In order to prevent malfunctions or injuries due to leaking or 
explosions, be sure to remove the coin type battery when the unit 
will not be used for a long period of time.

Remote controller

Do not drop or place the remote controller in water.
(Damage may occur.)

Do not press the remote controller buttons with sharp objects.
(Damage may occur.)

The signals may not be received well of electronic lighting style 
fluorescent lamps (such as inverter fluorescent lamps) are in the 
same room. For these cases, discuss with the dealer.

If other electrical device operate by the remote controller, either 
separate them from the remote controller or discuss with the dealer.

„

Attaching the pleated filter

WARNING

Set the filter while the power supply plug is not plugged in.

CAUTION

The unit must be operated with a pre-filter.
If they are not set and the unit is operated, malfunctions may occur.

1. Remove the front panel.

• Place your fingers in the indentations on the bottom of the unit 

and pull forward, holding on to the bottom of the panel. 

CAUTION

Do this before plugging the unit into a power supply. 

Always install the pleated filter before running the unit.

2. Remove the shock-absorbing material and then remove 

the plasma ionizer.

1) Remove the shock-absorbing material. 

2) Holding the handle, lift towards yourself and remove from the top 

2 hooks.

Receiver

Front panel

Shock-absorbing 
material (cardboard)

Plasma ionizer

Hooks 
(one left and one right)

01_EN_3P167171-3E.fm  Page 5  Monday, August 7, 2006  6:45 PM

Summary of Contents for MC707PVM

Page 1: ...OPERATION MANUAL MODEL MC707PVM PHOTOCATALYTIC AIR PURIFIER 00_CV_3P167171 3E fm Page 1 Monday July 31 2006 2 55 PM...

Page 2: ...place where air is circulated throughout the room The air blows slightly slant to the right When you want to remove house dust setting up the air purifier in low rooms is effective When you want to re...

Page 3: ...mum 2m from lighting TVs radios stereos and aerials This unit can disturb TV pictures and generate interference Illumination can weaken remote controller signal reception sensitivity and discolor the...

Page 4: ...to the room Note cannot be washed with water 12 Filter container Six replacement pleated filters are included 13 Ventilation fan 14 Air inlet 15 Remote controller storage slot Stores the accessory rem...

Page 5: ...operation 5 Airflow rate indicator green page 7 Lit by the set airflow rate setting The air volume lamp is on during automatic or manual operation 6 Turbo mode indicator green page 7 Lit during turbo...

Page 6: ...ly 1 year but if the reception becomes difficult replace the batteries with new coin type battery CR2025 Coin type battery close to the recommended usage period may need to be replaced soon In order t...

Page 7: ...of the bio antibody filter on the hooks 2 locations of the plasma ionizer 3 Restore the pre filter Hook the bottom part of the pre filter on the bottom hooks 2 locations of the plasma ionizer and the...

Page 8: ...e will be lit in the OFF timer setting indicator When the set time is reached the operation will automatically stop The set time can be changed if the button is pressed while the timer is operating 8...

Page 9: ...lfunction may occur Cleaning the air inlet for the dust odor sensor Clean dusts clogged in the air inlet for the dust odor sensor Use crevice nozzle of a cleaner for cleaning Cleaning the front panel...

Page 10: ...exposed to the sun Do not clean with water hotter than 50 C Do not burn with fire Color changes or deformation may occur and the unit may become unusable Replacing the bio antibody filter The bio anti...

Page 11: ...et switch with a sharp material such as a tooth pick to turn off the replacement sign It will beep NOTE Replace a pleated filter Contact your dealer for replacement pleated filter It is not necessary...

Page 12: ...t to cut your hands with the opposing pole plate or ionizer wires It is safer to use rubber gloves CAUTION There are ionizer wires at back of the opposing pole plate When attaching or removing be care...

Page 13: ...equipment may result Rinse with running water Soak in water or warm water to remove detergent about 30 minutes Caution Soak well as cleaning sign may be on even after cleaning if any detergent remain...

Page 14: ...with a soft cloth 2 Streamer discharger Clean off the internal resin part with a soft cloth For removal see page 11 3 Ionizing frame Clean off the resin part with a soft cloth Use a cotton bud to wip...

Page 15: ...le plate while opening the knobs one at a side of the plasma ionizer 3 Insert securely until it clicks 4 Attach another side of the opposing pole plate 2 Attach the streamer discharger 1 Insert bottom...

Page 16: ...ER button The receive sound will beep and the setting lamp will flash 4 Unplug the power plug one time and then after 3 seconds or more plug it in again This completes the settings NOTE If the operati...

Page 17: ...eign matter For other cases contact your dealer Air does not come out Cleaning effect is not obtained Is the unit installed at a location where the flow does not pass or are there obstructions close t...

Page 18: ...17 English MEMO 01_EN_3P167171 3E fm Page 17 Monday August 7 2006 6 45 PM...

Page 19: ...0608 HT 3P167171 3E M05B114C 00_CV_3P167171 3E fm Page 2 Monday July 31 2006 2 55 PM...

Reviews: