Main unit display

1 Air intake for dust sensor

Air is taken in from here and the dust sensor detects the dirty state 
of the air.

2 Clean monitor (Dust)

Detects the dirty state of the air and indicates the results.

• In the following case, only the green light is on for the first 

7 seconds regardless of pollution from the air.
• Operation directly after setting the front panel or plasma ionizer
• Operation directly after inserting the power plug

• You can change sensitivity setting of the dust sensor lamp.

3 Clean monitor (Odor)

Detects changes to odors and indicates the results.

• Reactions to sudden temperature/humidity changes and odorless 

gas (carbon monoxide) may occur.

• There may not be any reaction for a uniform case without any 

changes to the intensity of the odor.

• There may be no reaction to pet odors or garlic odors.
• Different people have different sensitivity to odors so you may not 

notice an odor even though the lamp is green.

• In the following case, only the green light is on for the first 

1 minute and this state is regarded as the reference value of the 
odor sensor.
• Operation directly after setting the front panel or plasma ionizer
• Operation directly after inserting the power plug

4 Automatic operation indicator (yellow)

Lit during automatic operation.

5 Airflow rate indicator (green)

 (page 7.)

Lit by the set airflow rate setting.
(The air volume lamp is on during automatic or manual operation.)

6 Turbo mode indicator (green)

 (page 7.)

Lit during turbo mode.

7 Anti-pollen mode indicator

 (page 7.)

Lit during pollen mode.

8 Negative ion mode indicator

 (page 7.)

Indicates during negative ion operation.

9 OFF timer setting indicator (yellow)

 (page 7.)

Indicates the set OFF timer time.
Indicates the remaining time after setting as the time passes.

10 Clean indicator (red)

 (pages 11, 12.)

The lamp will blink for cleaning time of the plasma ionizer.

11 Replace indicator (red) / Reset button

The lamp will be on for replacement time of the pleated filter and 
blink after certain time has elapsed from the turning on.

*

Press the reset button after replacement. (page 10.)

12 Lock lamp

 (page 7.)

Lit during lock.

13 Air intake for odor sensor

Air is taken in from here and the odor sensor detects the odor state.

14 Receiver

Receives signals from the remote controller.

15 Operation switch / stop button

Each time this button is pressed, the operation mode switches as 
shown below.

*

During automatic operation the airflow rate at that time will also be 
lit.

1

2

3

13

15

14

12

11

10

9

8

7

6

5

4

Dust

Low

High

Green

Green

Green

 

Yellow

Yellow

 

 

Red

Indicator

Off

On

Odor

Weak

Strong

Green

Green

Green

 

Yellow

Yellow

 

 

Red

Indicator

Off

On

“ ”

“ ”

“ ”

“ ”

“ ”

“ ”

“

”

(Automatic)

LL (Quiet)

L (Low)

M (Standard)

(Stop)

(Pollen)

HH (Turbo)

H (High)

01_EN_3P167171-3E.fm  Page 4  Monday, August 7, 2006  6:45 PM

Summary of Contents for MC707PVM

Page 1: ...OPERATION MANUAL MODEL MC707PVM PHOTOCATALYTIC AIR PURIFIER 00_CV_3P167171 3E fm Page 1 Monday July 31 2006 2 55 PM...

Page 2: ...place where air is circulated throughout the room The air blows slightly slant to the right When you want to remove house dust setting up the air purifier in low rooms is effective When you want to re...

Page 3: ...mum 2m from lighting TVs radios stereos and aerials This unit can disturb TV pictures and generate interference Illumination can weaken remote controller signal reception sensitivity and discolor the...

Page 4: ...to the room Note cannot be washed with water 12 Filter container Six replacement pleated filters are included 13 Ventilation fan 14 Air inlet 15 Remote controller storage slot Stores the accessory rem...

Page 5: ...operation 5 Airflow rate indicator green page 7 Lit by the set airflow rate setting The air volume lamp is on during automatic or manual operation 6 Turbo mode indicator green page 7 Lit during turbo...

Page 6: ...ly 1 year but if the reception becomes difficult replace the batteries with new coin type battery CR2025 Coin type battery close to the recommended usage period may need to be replaced soon In order t...

Page 7: ...of the bio antibody filter on the hooks 2 locations of the plasma ionizer 3 Restore the pre filter Hook the bottom part of the pre filter on the bottom hooks 2 locations of the plasma ionizer and the...

Page 8: ...e will be lit in the OFF timer setting indicator When the set time is reached the operation will automatically stop The set time can be changed if the button is pressed while the timer is operating 8...

Page 9: ...lfunction may occur Cleaning the air inlet for the dust odor sensor Clean dusts clogged in the air inlet for the dust odor sensor Use crevice nozzle of a cleaner for cleaning Cleaning the front panel...

Page 10: ...exposed to the sun Do not clean with water hotter than 50 C Do not burn with fire Color changes or deformation may occur and the unit may become unusable Replacing the bio antibody filter The bio anti...

Page 11: ...et switch with a sharp material such as a tooth pick to turn off the replacement sign It will beep NOTE Replace a pleated filter Contact your dealer for replacement pleated filter It is not necessary...

Page 12: ...t to cut your hands with the opposing pole plate or ionizer wires It is safer to use rubber gloves CAUTION There are ionizer wires at back of the opposing pole plate When attaching or removing be care...

Page 13: ...equipment may result Rinse with running water Soak in water or warm water to remove detergent about 30 minutes Caution Soak well as cleaning sign may be on even after cleaning if any detergent remain...

Page 14: ...with a soft cloth 2 Streamer discharger Clean off the internal resin part with a soft cloth For removal see page 11 3 Ionizing frame Clean off the resin part with a soft cloth Use a cotton bud to wip...

Page 15: ...le plate while opening the knobs one at a side of the plasma ionizer 3 Insert securely until it clicks 4 Attach another side of the opposing pole plate 2 Attach the streamer discharger 1 Insert bottom...

Page 16: ...ER button The receive sound will beep and the setting lamp will flash 4 Unplug the power plug one time and then after 3 seconds or more plug it in again This completes the settings NOTE If the operati...

Page 17: ...eign matter For other cases contact your dealer Air does not come out Cleaning effect is not obtained Is the unit installed at a location where the flow does not pass or are there obstructions close t...

Page 18: ...17 English MEMO 01_EN_3P167171 3E fm Page 17 Monday August 7 2006 6 45 PM...

Page 19: ...0608 HT 3P167171 3E M05B114C 00_CV_3P167171 3E fm Page 2 Monday July 31 2006 2 55 PM...

Reviews: