Daikin Madoka Installation And Operation Manual Download Page 2

Table of contents

Installation and operation manual

2

BS

Madoka wired remote controller

4P596265-1 – 2019.11

Table of contents

1 General safety precautions

2

1.1

For the user ...............................................................................

2

1.2

For the installer..........................................................................

3

2 About this document

3

For the user

4

3 Remote controller: Overview

4

3.1

About the controller ...................................................................

4

3.2

Buttons ......................................................................................

4

3.3

Status icons ...............................................................................

4

3.4

Status indicator..........................................................................

5

4 Operation

5

4.1

Basic usage ...............................................................................

5

4.1.1

Home screen...............................................................

5

4.1.2

Main menu ..................................................................

5

4.2

Operation mode.........................................................................

6

4.2.1

To set the operation mode ..........................................

6

4.3

Setpoint .....................................................................................

6

4.3.1

To set the setpoint ......................................................

6

4.4

Date and time ............................................................................

6

4.4.1

To set date and time ...................................................

6

4.5

Airflow........................................................................................

7

4.5.1

Airflow direction...........................................................

7

4.5.2

Fan speed ...................................................................

7

4.6

Ventilation..................................................................................

7

4.6.1

Ventilation mode .........................................................

7

4.6.2

Ventilation rate ............................................................

7

4.7

Advanced usage........................................................................

8

5 Maintenance and service

8

5.1

Overview: Maintenance and service .........................................

8

6 Troubleshooting

8

6.1

Overview: Troubleshooting........................................................

8

6.2

Refrigerant leak detection .........................................................

8

6.2.1

To stop the leak detection alarm.................................

8

For the installer

8

7 About the box

8

7.1

To unpack the controller ............................................................

8

8 Preparation

9

8.1

Wiring requirements ..................................................................

9

9 Installation

9

9.1

Mounting the controller ..............................................................

9

9.1.1

To mount the controller ...............................................

9

9.2

Connecting the electrical wiring.................................................

9

9.2.1

To connect the electrical wiring...................................

9

9.3

Closing the controller.................................................................

10

9.3.1

To close the controller................................................. 10

10 Starting up the system

10

11 Maintenance

10

11.1

Maintenance safety precautions................................................

10

11.2

To clean the controller ...............................................................

10

11.3

Time to clean filter indication .....................................................

11

11.3.1

To remove the Time to clean filter indication .............. 11

1

General safety precautions

Please  read  these  general  safety  precautions  carefully  before
installing  air  conditioning  equipment,  and  be  sure  to  install  the
equipment correctly.

Failure  to  follow  these  instructions  properly  may  result  in  property
damage or personal injury, which may be serious depending on the
circumstances.

Meaning of warnings and symbols

These  safety  messages  are  used  to  attract  your  attention.  The
meaning of each safety message is described below:

WARNING

Indicates  a  situation  that  could  result  in  death  or  serious
injury.

CAUTION

Indicates a situation that could result in minor or moderate
injury.

DANGER

Indicates a situation that results in death or serious injury.

DANGER: RISK OF EXPLOSION

Indicates a situation that could result in explosion.

INFORMATION

Indicates useful tips or additional information.

NOTICE

Indicates  a  situation  that  could  result  in  equipment  or
property damage.

1.1

For the user

INFORMATION

Also  see  the  operation  manual  delivered  with  the  outdoor
and indoor unit.

WARNING

Do  NOT  play  with  the  unit  or  its  remote  controller.
Accidental operation by a child may result in impairment of
bodily functions and harm health.

WARNING

To prevent electric shocks or fire:

▪ Do NOT operate the controller with wet hands.

▪ Do  NOT  disassemble  the  controller  and  touch  interior

parts. Contact your dealer.

▪ Do  NOT  modify  or  repair  the  controller.  Contact  your

dealer.

▪ Do  NOT  relocate  or  reinstall  the  controller  by  yourself.

Contact your dealer.

WARNING

Do  NOT  use  flammable  materials  (e.g.  hairspray  or
insecticide) near the controller.

NOTICE

To clean the controller, do NOT use organic solvents, such
as paint thinner. 

Possible consequence: 

damage, electric

shock, or fire.

Summary of Contents for Madoka

Page 1: ...Installation and operation manual Madoka wired remote controller English Installation and operation manual Madoka wired remote controller BRC1H82W BRC1H82S ...

Page 2: ...al safety precautions Please read these general safety precautions carefully before installing air conditioning equipment and be sure to install the equipment correctly Failure to follow these instructions properly may result in property damage or personal injury which may be serious depending on the circumstances Meaning of warnings and symbols These safety messages are used to attract your atten...

Page 3: ...nduct a trial operation to check for faults Explain the user how to operate the controller Ask the user to store the manual for future reference This controller is part of a refrigerant leak detection system for safety To be effective the system must be electrically powered at all times after installation other than when servicing INFORMATION Consult your dealer regarding the relocation and reinst...

Page 4: ...OFF When OFF press to turn ON the system When ON press to turn OFF the system b ENTER ACTIVATE SET From the home screen enter the main menu From the main menu enter one of the submenus From their respective submenu activate an operation ventilation mode In one of the submenus confirm a setting c CYCLE ADJUST Cycle left Adjust a setting default decrease d CYCLE ADJUST Cycle right Adjust a setting d...

Page 5: ... is no longer running with restricted capacity Rotation Indicates that Rotation mode is active Setback Indicates that the indoor unit is operating under setback conditions Ventilation Indicates that a heat reclaim ventilation unit is connected INFORMATION For information on the operation mode and ventilation mode icons see 4 2 Operation mode 4 6 and 4 6 1 Ventilation mode 47 respectively Most icon...

Page 6: ...lation Air Clean Combination of ventilation and air clean operation Auto In Auto mode the indoor unit automatically switches between heating and cooling mode as required by the setpoint INFORMATION Depending on the indoor unit more or less operation modes are available 4 2 1 To set the operation mode 1 Navigate to the operation mode menu 2 Use and to select an operation mode 3 Press to activate Re...

Page 7: ... units 4 6 1 Ventilation mode The heat reclaim ventilation unit can operate in various operation modes Icon Ventilation mode Energy Reclaim Ventilation The outdoor air is supplied to the room after passing through a heat exchanger Bypass The outdoor air is supplied to the room without passing through a heat exchanger Auto To ventilate the room in the most efficient way the heat reclaim ventilation...

Page 8: ...home screen Error screen example INFORMATION If the controller is set to be operable in Supervisor mode then the controller adds the supervised room address of the faulty indoor unit to the error screen In Supervisor mode it is mandatory to set a unique supervised room address for every indoor unit The supervised room address can be set in the Madoka Assistant app CH 02 1234 For more information a...

Page 9: ...rom the left c Wiring from the bottom In case you are routing the wiring from the rear you don t have to remove anything 9 1 1 To mount the controller 1 Take the screws and plugs from the accessory bag 2 Mount the rear casing to a flat surface INFORMATION If required e g when mounting to a flush mounted electrical installation box mount the rear casing by way of the knockout holes NOTICE When moun...

Page 10: ... designated as a Normal master controller INFORMATION For more information on how to designate the controller to be of a different type i e operable in Normal Alarm only or Supervisor mode as master controller or as slave controller see the installer and user reference guide 11 Maintenance 11 1 Maintenance safety precautions WARNING Before carrying out any maintenance or repair activities stop sys...

Page 11: ...icate this by displaying in the top left corner of the home screen and confronting you with the Time to clean filter screen as soon as you try to enter the main menu from the home screen 11 3 1 To remove the Time to clean filter indication Prerequisite On trying to enter the main menu from the home screen you are confronted with the Time to clean filter screen 1 Clean the filter 2 Press to remove ...

Page 12: ...017 3281 OMAN TRA TRA TA R 5107 18 D100428 TRA REGISTERED No ER63033 18 DEALER No DA73526 18 И005 18 TRC LPD 2018 60 4P596265 1 2019 11 Copyright 2019 Daikin 4P596265 1 0000000V Verantwortung für Energie und Umwelt ...

Reviews: