![background image](http://html1.mh-extra.com/html/daikin/lxe10e-a/lxe10e-a_service-manual_2460253040.webp)
Partial
frozen
2-26
2.5.5 Common control
The following are controlled in different operation modes. (For the details, refer to the following pages.)
Control name
Control content
Operation mode
Frozen Chilled
Defrost
A Compressor ON/OFF control
The compressor is operated on and off to
adjust the inside temperature.
○
B Starting control
At the start of the operation with low ambient
temperature,an oil temperature raising control is executed.
When a protection device activates at the operation
○
○
○
start, a high pressure/current control is executed.
C Evaporator fan speed control
The evaporator fan is switched to the high or low
speed according to the set point temperature.
○
○
○
In order to keep the superheat of the evaporator
D Superheat control
optimum,the opening of the electronic expansion
○
valve is controlled.
E High-pressure control
In order to keep the high pressure optimum, the
opening of the electronic expansion valve is controlled.
○
○
○
In order to prevent the refrigerant oil from
F Injection
deteriorating, the injection solenoid valve control or
○
○
○
electronic expansion valve control is carried out.
G In-range control
When the control temperature is within SP ±2˚C,
the in-range lamp is turned on.
○
○
○
H In-range masking control
After defrosting initiation, the in-range lamp
is kept on for 90 minutes.
○
○
○
○
The circulating flow rate of refrigerant is proportionally
I
Capacity control
controlled with suction modulating valve to keep the
○
○
control temperature variation within ±0.5˚C.
J Charging and releasing control
These functions control the heating capacity
for defrosting and heating operation.
○
○
○
K Pump down control
The liquid refrigerant is collected into the liquid receiver
(water cooled condenser).
○
○
○
○
L Economizer control
The economizer circuit is controlled to enhance
cooling capacity.
○
○
○
M Dehumidification (optional)
The unit can execute dehumidification by
reheat coil and humidity sensor.
○
02̲LXE10E-A(17-29) 07.2.20 15:39 ページ 2-26
https://daikin-p.ru
Summary of Contents for LXE10E-A
Page 177: ...7 8 https daikin p ru...
Page 220: ...8 37 2 2 Inside 1 q Reheat coil https daikin p ru...
Page 237: ...MEMO https daikin p ru...