IM 796
Page 7
Mounting Plate Installation
The mounting plate ships attached to the back of the indoor
unit. To detach for mounting on wall, remove plastic rivet
from bottom (pry loose with a knife blade) and unhook.
The wall must be strong enough to support the weight of the
unit. If necessary, reinforce the wall. Drill holes in plate to
align with wall studs and attach with four (4) screws.
If the refrigerant piping is going thru the wall behind the
indoor unit, provide a 2-1/2" hole that is slightly pitched to
the outside.
See
Figure 5
. Hole must be located in alignment
with the arrows on the mounting plate.
See Figure 6
.
Figure 5. Wall Opening for Piping
Figure 6. Mounting Plate/Wall Opening
Installing Unit on Mounting Plate
Hook the indoor unit onto the upper portion of the mounting
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the plate). Properly seat the hooks and
replace the plastic rivet at the bottom.
Figure 7. Installing Unit on Mounting Plate
Drain Hose Installation
The condensate drain hose (20" long) comes factory attached
to the indoor unit. It is gravity flow. Avoid situations that
could restrict drainage.
See Figure 8
.
Figure 8. Drain Hose Installation
Indoor
2 ½” Dia. hole
side
Outdoor
side
2 ½”Dia. Hole
Correct
NOT
Correct
NOT
Correct
NOT
Correct