background image

1

English

CONTENTS

  SAFETY CONSIDERATIONS .....................................[i] [ii]
1. NAMES AND FUNCTIONS OF PARTS ............................ 1
2. MAINTENANCE  

(FOR SERVICE PERSONNEL) ....................................... 1

1. 

NAMES AND FUNCTIONS OF PARTS

i

j

k

a

b

g

f

c

e

h

d

a

Air outlet

Fan airflow can be set to 1 of 3 settings or auto (Note) 

from the remote controller.
(Note)  Auto fan speed control is only available when 

using the wired remote controller.

b

Horizontal blade (inside air outlet)

Vertical airflow direction can be set to swing, 1 of 5 

settings or auto (Note) from the remote controller.
(Note)  Auto airfrow direction is only available when 

installing the optional sensor kit and using the 
wired remote controller.

c

Suction grille
(Refer to “

2. MAINTENANCE

”)

d

Air filter (inside suction grille)

(Refer to “

2. MAINTENANCE

”)

e

Air outlet identification mark

(

)

Use this mark as a reference for setting the individual 

airflow direction.

(only when using wired remote controller)

f

Remote controller (optional accessory)
The remote controller may not be needed depending 

on the system configuration. 

g

Drain piping

h

Drain pump (built-in)
It drains moisture in the room removed during the 
cooling operation.

i

Refrigerant piping

j

Transmission wiring (field installed)
Power supply wiring (field installed)

k

Ground wiring (Note)

(Note)  Ground wiring allows electricity flow from the 

indoor unit to the ground for prevention of 

electric shock or a fire in case of emergency.

2.  MAINTENANCE  

(FOR SERVICE PERSONNEL)

ONLY A QUALIFIED SERVICE PERSON IS 

ALLOWED TO PERFORM MAINTENANCE

 WARNING

• 

Do not use flammable gas (such as hair sprays and 

insecticides) near the air conditioner.

• 

Do not wipe the air conditioner with benzine or thinner. 

It may cause cracks, electric shock or a fire.

• 

Never put your fingers or rods in the suction grille, air 

outlet or horizontal blade. The fan is rotating at high 

speed, so you would get injured.

 CAUTION

• 

Do not wash the air conditioner with water.

 

It may cause electric shock or a fire due to leakage.

• 

Make sure to turn off the air conditioner when taking 

care of the air conditioner and disconnect the power 

supply breaker.

 

Unless the power supply is disconnected, it may cause 

electric shock and injury.

NOTE 

• 

Do not remove the air filter except for cleaning. 

Operating the unit without an air filter may result in 

failure.

• 

Do not attach substances (such as paper towels) other 

than the specified air filter to the suction grille. The 

performance may drop and cause freeze-up/water 

leakage.

HOW TO CLEAN THE AIR FILTER

When the remote controller indicates a filter sign, clean the air 
filter.

• 

The sign is made after the system runs for a defined period 

of time.

NOTE 

• 

You may change the interval of indicating the filter sign.

 

If the indoor unit is used in a space where the air is 

more contaminated, ask your local dealer for solution.

Dust level

Time until sign is displayed

Normal

2500 hours (equivalent to one year)

More contaminated

1250 hours (equivalent to a half year)

• 

If it becomes difficult to remove dust from the air filter, 
replace the air filter. 

 

(The replacement air filter is an optional accessory.)

01_EN_3P494229-2D.indd   1

2021/12/03   9:35:18

Summary of Contents for FXZQ05TBVJU

Page 1: ...Lisez attentivement ce manuel avant d utiliser le climatiseur Il vous expliquera comment vous servir correctement de l appareil et vous guidera en cas de problème Ce manuel ne décrit que l unité intérieure Utilisez le avec le manuel de l unité extérieure Lorspue vous aurez lu le manuel rangez le afin de pouvoir vous y référer ultérieurement Le agradecemos la compra de este acondicionador de aire D...

Page 2: ...epair and maintenance Improper repair and maintenance may result in water leakage electric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a pro fessional Contact your dealer to move and reinstall the air con ditioner Incomplete installation may result in water leakage electric shock and fire Never let the indo...

Page 3: ... contact with electrical parts NOTE Never press the button of the remote controller with a hard pointed object The remote controller may be damaged Never pull or twist the electric wire of the remote con troller It may cause the unit to malfunction Do not place appliances that produce open flames in places that are exposed to the airflow of the unit or un der the indoor unit It may cause incomplet...

Page 4: ... IS ALLOWEDTO PERFORM MAINTENANCE WARNING Do not use flammable gas such as hair sprays and insecticides near the air conditioner Do not wipe the air conditioner with benzine or thinner It may cause cracks electric shock or a fire Never put your fingers or rods in the suction grille air outlet or horizontal blade The fan is rotating at high speed so you would get injured CAUTION Do not wash the air...

Page 5: ...g a soft brush After dewatering dry the air filter in the shade NOTE Do not wash the air filter with hot water of 122 F 50 C or higher It may cause discoloration and deformation When drying the air filter do not heat it with fire It may cause burning Do not use chemicals such as gasoline benzine thin ner polishing powder and liquid insecticide It may cause discoloration and deformation 4 Attach th...

Page 6: ...h fire It may cause burning Do not use chemicals such as gasoline benzine thin ner polishing powder and liquid insecticide It may cause discoloration and deformation 5 Attach the air filter Refer to step 4 of HOWTO CLEANTHE AIR FILTER page 2 6 Attach the suction grille Position the suction grille to a roughly 90 angle and while holding the suction grille with one hand squeeze the suction grille hi...

Page 7: ...G OPERATION is performed within 6 hours after power is supplied to the air conditioner the indoor fan stops for about 10 minutes during the outdoor unit operation to protect the equipment The above operation is performed not only for installation but every time the power circuit breaker is turned off on For comfortable use do not turn off the power circuit breaker during seasonal use of the HEATIN...

Page 8: ...Daikin Texas Technology Park 19001 Kermier Road Waller TX 77484 U S A 2204 HT 3P494229 2D EM21A013 00_CV_3P494229 2D indd 4 2022 02 07 14 35 38 ...

Reviews: