VRV SYSTEM Inverter Air Conditioners

Installation manual

Contents

Before installation ……………………………………………………… 1
Selecting installation site ……………………………………………… 2
Preparations before installation ……………………………………… 3
Indoor unit installation ………………………………………………… 3
Refrigerant piping work ……………………………………………… 4
Drain piping work ……………………………………………………… 5
Electric wiring work …………………………………………………… 6

Wiring example and how to set the remote controller

 ……………… 7

Wiring example

 ………………………………………………………… 8

Installation of the decoration panel …………………………………… 8
Field setting …………………………………………………………… 8
Test operation ………………………………………………………… 10

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE 
FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF 
EQUIPMENT OR ACCESSORIES COULD RESULT IN 
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR 
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY 
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE 
SPECIFICALLY DESIGNED FOR USE WITH THE 
EQUIPMENT AND HAVE THEM INSTALLED BY A 
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE, 
ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE 
AND INFORMATION.

The English text is the original instruction. Other languages are 

translations of the original instructions.

Before installation

 

„

Leave the unit inside its packaging until you reach the installation 
site. Where unpacking is unavoidable, use a sling of soft material or 
protective plates together with a rope when lifting, this to avoid 
damage or scratches to the unit. 
When unpacking the unit or when moving the unit after unpacking, 
be sure to lift the unit by holding on to the hanger bracket without 

exerting any pressure on other parts, especially on refrigerant 

piping, drain piping and other resin parts.

 

„

Refer to the installation manual of the outdoor unit for items not 
described in this manual.

 

„

Caution concerning refrigerant series R410A: 

The connectable outdoor units must be designed exclusively for 

R410A.

Precautions

 

„

This appliance is not intended for use by persons, including 
children, with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 
Children should be supervised to ensure that they do not play with 
the appliance.

 

„

This appliance is intended to be used by expert or trained users in 

shops, in light industry and on farms, or for commercial use by lay 
persons.

 

„

Do not install or operate the unit in rooms mentioned below.

 

-

Places with mineral oil, or filled with oil vapour or spray like in 

kitchens. (Plastic parts may deteriorate.)

 

-

Where corrosive gas like sulphurous gas exists. (Copper 

tubing and brazed spots may corrode.)

 

-

Where volatile flammable gas like thinner or gasoline is used.

 

-

Where machines generating electromagnetic waves exist. 

(Control system may malfunction.)

 

- Where the air contains high levels of salt such as air near the 

ocean and where voltage fluctuates a lot (e.g. in factories). 

Also in vehicles or vessels.

 

„

When selecting the installation site, use the supplied paper pattern 
for installation.

 

„

Do not install accessories on the casing directly. Drilling holes in the 

casing may damage electrical wires and consequently cause fire.

Accessories

Check if the following accessories are included with your unit.

1 pc.

1 pc.

8 pcs.

4 pcs.

1 pc. each

7 pcs.

1 pc.

1 pc.

1 pc.

1 pc.

1 pc.

1 pc.

8

9

11

10

12

13

1

2

3

1 pc.

14

5

4

6

1 pc.

7

Metal clamp

Drain hose

Washer for hanger bracket

Screw

Installation and operation manuals

Clamp

Insulation for fitting for gas pipe

Insulation for fitting for liquid pipe

Large sealing pad

10 

Medium 1 sealing pad

11 

Medium 2 sealing pad

12 

Small sealing pad

13 

Paper pattern for installation (cut out from upper part of packing)

14 

Washer for conduit

Page

01_EN_3P493125-1.indd   1

9/21/2017   10:16:28

Summary of Contents for FXZQ05TAVJU

Page 1: ...anual in a handy place for future reference This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel à portée de main pour référence ultérieure Ce manuel doit être donné au propriétaire de l équipement Lea cuidadosamente estas instrucciones antes de instalar Guarde este manual en un lugar a mano para leer en caso de tener algu...

Page 2: ...205 8 11 16 220 BYFQ60C BYFQ60B 25 3 8 645 H1 H2 24 13 16 630 8 2 4 7 1 9 10 5 6 5 2 7 4 3 5 6 7 7 1 16 180 13 16 20 13 16 20 2 1 2 63 27 9 16 700 1 22 5 8 575 3 21 533 4 23 1 16 26 585 660 2 23 1 16 26 585 660 2 27 9 16 700 1 23 1 16 26 585 660 2 22 5 8 575 3 21 533 4 8 11 1 4 285 6 24 7 16 620 1 7 1 2 190 23 1 16 23 7 16 585 595 2 22 5 8 575 3 24 7 16 620 1 23 1 16 23 7 16 585 595 2 1 2 12 5 1 2...

Page 3: ...2 3 5 IN D OUT D F1 F2 F1 F2 Control box L2 L1 P1 P2 P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 F1 F2 T1 T2 L2 L1 P1 P2 P1 P2 F1 F2 T1 T2 L2 L1 L2 L1 P1 P2 P1 P2 F1 F2 T1 T2 L1 L2 1 4 2 3 14 IN D OUT D F1 F2 F1 F2 Control box IN D OUT D F1 F2 F1 F2 Control box P1 P2 L2 L1 P1 P2 F1 F2 T1 T2 1 6 2 3 16 A B 4 4 4 4 2 3 2 3 17 A B 18 10 Unit in mm 2 1 5 4 4 100 3 11 2 2 L1 L2 L1 L2 1 L1 L2 L1 L2 2 3 4 5 6 1 L1 L2 ...

Page 4: ... may cause injuries or death by suffocation WARNING Only qualified personnel must carry out the installa tion work Installation must be done in accordance with this installation manual Improper installation may result in water leakage electric shock or fire When installing the unit in a small room take mea sures to keep the refrigerant concentration from ex ceeding allowable safety limits Excessiv...

Page 5: ...nit is for R410A See the catalog for in door models that can be connected Normal operation is not possible when connected to other units Remote controller wireless kit transmitting distance can be shorter than expected in rooms with electronic fluorescent lamps inverter or rapid start types Install the indoor unit far away from fluorescent lamps as much as possible Indoor units are for indoor inst...

Page 6: ...0A The connectable outdoor units must be designed exclusively for R410A Precautions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised ...

Page 7: ...oor unit b Lighting The figure describes a surface mounted light but a recessed ceiling light is not restricted c Air fan A If the air outlet is closed space marked A should be 8 in 200 mm at least B 60 in 1500 mm from any static obstruction 1 Select an installation site where the following conditions are fulfilled and that meets your customer s approval Where optimum air distribution can be ensur...

Page 8: ...making an opening in the ceiling it may be necessary to reinforce ceiling beams to keep the ceiling level and to prevent it from vibrating Consult the builder for details 3 Install the suspension bolts Use either a M8 M10 size bolt or equivalent Use anchors for existing ceilings and a sunken insert sunken anchors or other field supplied parts for new ceilings to reinforce the ceiling in order to b...

Page 9: ...rant such as air etc inside the refrigerant circuit Only use annealed material for flare connections Refer to Table 1 for the dimensions of flare nut spaces and the appropriate tightening torque Overtightening may damage the flare and cause leaks Table 1 Pipe size Tightening torque Flare dimensions A in Flare φ1 4 10 4 12 7 ft lbf 0 342 0 358 R0 016 0 031 φ1 2 36 5 44 5 ft lbf 0 638 0 654 Refer to...

Page 10: ...g of drain piping is finished attach the drain sealing pad 4 supplied with the unit over the uncovered part of the drain socket between drain hose and unit body 1 5 2 3 4 3 4 2 A A A A 1 1 Drain socket attached to the unit 2 Drain hose supplied with the unit 3 Metal clamp supplied with the unit NOTE Bend the tip of the metal clamp without tearing the sealing 4 Large sealing pad supplied with the u...

Page 11: ... wire 4 Terminal block for power supply 5 Clamp 6 Transmission wiring 7 Terminal block for transmission wiring 8 Openings for wires 9 Wiring diagram label on the back side of the control box lid 10 Remote controller wiring Terminal block for power supply 4 L1 L2 Confirm the drain operation looking at the drain socket After checking the drainage flow turn off power remove the control box lid and di...

Page 12: ...set the remote controller Connection of power supply transmission and remote controller wiring How to connect wiring See figure 9 1 Remove the control box lid 2 screws 1 2 1 Screws 2 Control box lid 2 Insert the power supply and ground wires into the conduit pipe and secure the conduit to the hole in the control box using the lock nut and the washer for conduit as shown below 5 3 7 8 6 4 3 Hole in...

Page 13: ...ightly connect wires to the terminals Be careful that wires do not place external stress on the terminals Keep wiring in neat order so that they do not obstruct other equipment such as popping open the service cover Make sure the cover closes tight Incomplete connections could result in overheating and in the worst case electric shock or fire Wiring example Fit the power supply wiring of each unit...

Page 14: ...peed 4 Differential automatic changeover 0 F 0 C 1 8 F 1 C 3 6 F 2 C 5 4 F 3 C See note 6 5 Auto restart after power failure Disabled Enabled 6 Fan setting during thermostat OFF at cooling operation LL Set speed 13 23 0 Setting for air outlet velocity This setting is to be changed in function of ceiling height 8 to 3 4 ft 2 7 m or less 8 3 4 to 10 2 7 3 0 10 to 11 1 2 3 0 3 5 1 Selection for air f...

Page 15: ...on Remote control is available by connecting the external input to the terminal T1 and T2 on the terminal block for transmission wiring F2 T1 T2 FORCED OFF Input A Wiring specification Sheathed vinyl cord or 2 core cable Gauge AWG18 16 0 75 1 25 mm2 Wiring length Max 328 ft 100 m External contact spec Contact that can make and break the min load of 15 V DC 1 mA 2 Actuation Input A of FORCED OFF an...

Page 16: ... 1709 HT 3P493125 1 EM17A018 ...

Reviews: