background image

INSTALLATION AND

OPERATION MANUAL

FXFQ20AVEB
FXFQ25AVEB
FXFQ32AVEB
FXFQ40AVEB
FXFQ50AVEB
FXFQ63AVEB
FXFQ80AVEB
FXFQ100AVEB
FXFQ125AVEB

 System air conditioners

EN3P320142-1F.book  Page 1  Tuesday, October 3, 2017  2:46 PM

Summary of Contents for FXFQ100AVEB

Page 1: ...INSTALLATION AND OPERATION MANUAL FXFQ20AVEB FXFQ25AVEB FXFQ32AVEB FXFQ40AVEB FXFQ50AVEB FXFQ63AVEB FXFQ80AVEB FXFQ100AVEB FXFQ125AVEB System air conditioners...

Page 2: ...valorado positivamente por B de acuerdo con el Certi cado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certi cato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer p...

Page 3: ...4 2 1 950 950 860 910 840 780 860 910 4 125 130 0 3 3 1 1 840 910 840 910 1 1 5 35 35 3 5 0 75 675 850 175 300 mm 1 1 5 m 2 3 1 5 6 100 mm 1 0 675 mm 1 3 3 1 2 4 100 4 3 5 1 2 2 2 1 4 70 90 mm 0 15 m...

Page 4: ...pervision If the supply cord is damaged it must be replaced by the manufacturer a service agent or similarly qualified persons in order to avoid a hazard Do not install or operate the unit in rooms me...

Page 5: ...TO THE MODELS AND VALUES STATED IN THIS TABLE Models A B C D E FXFQ20AVEB 1 8 0 4 2 5 0 038 49 FXFQ25AVEB 2 1 0 7 3 2 0 038 49 FXFQ32AVEB 2 8 0 8 4 0 038 49 FXFQ40AVEB 3 4 1 1 5 0 038 51 FXFQ50AVEB 4...

Page 6: ...r discharge in 3 directions it is necessary to make field settings by means of the remote controller and to close the air outlet s Refer to the installation manual of the optional blocking pad kit and...

Page 7: ...gure 8 Adjust the height of the unit until it matches the indication in figure 8 3 Adjust the unit to the right position for installation Refer to Preparations before installation on page 3 4 Check if...

Page 8: ...aks and eventually wet furniture and belongings Install the drain pipes Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped insid...

Page 9: ...rol box lid and turn on the power Do not touch the drain pump It may result in electric shock Confirm the drain operation looking at the drain socket After checking the drainage flow turn off the powe...

Page 10: ...er connection Attach the small sealing supplied with the unit around the cables to prevent infiltrating of water from the outside into the unit If two or more cables are used divide the small sealing...

Page 11: ...s no space between the unit body and decoration panel Otherwise air may leak through the gap and cause dewdrop Field setting Field setting must be made from the remote controller in accordance with th...

Page 12: ...high places After a long use check the unit stand and fitting for damage If damaged the unit may fall and cause injury Do not touch the heat exchanger fins The fins are sharp and could result in cutti...

Page 13: ...dry thoroughly See figure 24 5 Install the air filter back in place perform actions 2 to 4 in the illustration in reverse order 6 Reattach the suction grille by performing procedure step 2 in reverse...

Page 14: ...DEBRIDGE R RESISTOR DS DIP SWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FOR CHARACTERISTICS REFER TOPCBINSIDE YOUR UNIT FUSE S C LIMIT SWITCH FG CONNECTOR FRAMEGROUND S L FLOAT SWITCH H HARNESS...

Page 15: ...IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 1 4 2 3 5 IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1...

Page 16: ...3P320142 1F 2017 08 Copyright 2012 Daikin...