background image

Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product. 

Daikin units comply with the European regulations that
guarantee the safety of the product.

Pr

epared in B

elgium by Lannoo 

 (ww

w

.lannoop

rint.be), a com

pany whose concern for

 

the environm

ont is set in the E

M

AS

 and IS

O 1

4001 systems.

Responsibl

e E

ditor: 

D

aikin E

urope N.V

., Zandvoor

destraat 300,

 B

- 84

00 Oostende

The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy,
reliability or fitness for particular purpose of its content and the products and
services presented therein. Specifications are subject to change without
prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage,  in the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted by Daikin
Europe N.V..

VRV

®

 products are not within the scope of the Eurovent

certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin has
had the intension to become a leader in the provision
of products that have limited impact on the
environment. This challenge demands the eco design
and development of a wide range of products and an
energy management system, resulting in energy
conservation and a reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect human health
and the environment from the potential impact of our
activities, products and services and to assist in
maintaining and improving the quality of the environment.

Summary of Contents for FXFQ-PVE9 Series

Page 1: ...Round Flow Cassette FXFQ PVE9 air conditioning systems technical data ...

Page 2: ...Round Flow Cassette FXFQ PVE9 technical data air conditioning systems ...

Page 3: ...al Specifications 50Hz 3 Electrical Specifications 60Hz 3 2 Safety device settings 4 3 Options 4 4 Capacity tables 5 Cooling capacity tables 5 Heating capacity tables 7 5 Dimensional drawing centre of gravity 9 Dimensional drawing 9 Centre of gravity 11 6 Piping diagram 12 7 Wiring diagram 13 Wiring diagram 13 8 Sound data 14 Sound pressure spectrum 14 ...

Page 4: ...in 11 5 11 5 13 13 5 16 5 18 26 28 0 Low m min 10 10 11 11 13 5 15 20 22 5 Fan Motor Model QTS48C15M Output high W 56 56 56 56 56 56 120 120 Drive Direct drive Refrigerant Name R 410A Piping connections Liquid OD Type Flare connection Diameter mm 6 35 6 35 6 35 6 35 9 52 9 52 9 52 9 52 Gas Type Flare connection Diameter mm 12 7 12 7 12 7 12 7 15 9 15 9 15 9 15 9 Drain Diameter mm VP25 I D 25 O D 3...

Page 5: ...maller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse use a circuit breaker 1 3 ELECTRICAL SPECIFICATIONS 60HZ FXFQ25PVE9 FXFQ32PVE9 FXFQ40PVE9 FXFQ50PVE9 FXFQ63PVE9 FXFQ80PVE9 FXFQ100PVE9 FXFQ125PVE9 Power Supply Name VE Phase 1 Frequency Hz 60 Voltage V 220 Current Minimum circuit amps MCA A 0 3 0 3 0 3 0 3 0 4 0 5 1 3 1 5...

Page 6: ... KDDP55X160 Chamber connection kit KKSJ55K160 Insulation kit for high humidity KDTP55K80 KDTP55K160 High efficiency filter unit Colorimetric method 65 KAFP556H80 KAFP556H160 Colorimetric method 90 KAFP557H80 KAFP557H160 Replacement high efficiency filter Colorimetric method 65 KAFP552H80 KAFP552H160 Colorimetric method 90 KAFP553H80 KAFP553H160 Filter chamber KDDFP55H160 Replacement Long Life filt...

Page 7: ...9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 4 2 2 9 4 3 2 7 20 0 2 4 2 4 2 9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 4 2 2 8 4 3 2 7 21 0 2 4 2 4 2 9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 4 1 2 8 4 2 2 6 23 0 2 4 2 4 2 9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 4 1 2 8 4 2 2 6 25 0 2 4 2 4 2 9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 4 0 2 7 4 1 2 6 27 0 2 4 2 4 2 9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 4 0 2 7 4 1 2 6 29 0 2 4 2 4 2 9 2 6 3 4 2 8 3 6 2 9 3 8 2 9 3 9 ...

Page 8: ...6 1 5 3 7 2 6 2 8 4 6 7 9 0 7 0 9 6 7 1 10 4 7 0 10 6 6 6 23 0 6 1 5 3 7 2 6 2 8 4 6 7 9 0 7 0 9 6 7 1 10 2 6 9 10 4 6 5 25 0 6 1 5 3 7 2 6 2 8 4 6 7 9 0 7 0 9 6 7 1 10 1 6 8 10 3 6 5 27 0 6 1 5 3 7 2 6 2 8 4 6 7 9 0 7 0 9 6 7 1 9 9 6 7 10 1 6 4 29 0 6 1 5 3 7 2 6 2 8 4 6 7 9 0 7 0 9 5 7 1 9 8 6 6 10 0 6 4 31 0 6 1 5 3 7 2 6 2 8 4 6 7 9 0 7 0 9 4 7 0 9 6 6 6 9 8 6 3 33 0 6 1 5 3 7 2 6 2 8 4 6 7 9 ...

Page 9: ...2 6 2 6 2 6 2 6 2 6 2 5 14 7 15 0 2 7 2 7 2 7 2 7 2 7 2 7 12 6 13 0 2 9 2 8 2 8 2 8 2 8 2 8 10 5 11 0 3 0 3 0 3 0 3 0 3 0 3 0 9 5 10 0 3 1 3 1 3 1 3 1 3 0 3 0 8 5 9 1 3 1 3 1 3 1 3 1 3 1 3 1 7 0 7 6 3 2 3 2 3 2 3 2 3 2 3 2 5 0 5 6 3 4 3 4 3 4 3 4 3 4 3 4 3 0 3 7 3 5 3 5 3 5 3 5 3 5 3 5 0 0 0 7 3 7 3 7 3 7 3 7 3 7 3 5 3 0 2 2 3 9 3 9 3 9 3 9 3 7 3 5 5 0 4 1 4 1 4 1 4 0 3 9 3 7 3 5 7 0 6 0 4 2 4 2 4...

Page 10: ... 7 5 7 4 7 4 9 5 10 0 7 7 7 7 7 6 7 6 7 6 7 6 8 5 9 1 7 8 7 8 7 8 7 8 7 8 7 8 7 0 7 6 8 1 8 1 8 1 8 1 8 0 8 0 5 0 5 6 8 4 8 4 8 4 8 4 8 4 8 4 3 0 3 7 8 8 8 8 8 7 8 7 8 7 8 7 0 0 0 7 9 3 9 3 9 3 9 3 9 3 8 7 3 0 2 2 9 8 9 8 9 8 9 7 9 4 8 7 5 0 4 1 10 2 10 1 10 0 9 7 9 4 8 7 7 0 6 0 10 5 10 5 10 0 9 7 9 4 8 7 9 0 7 9 10 8 10 6 10 0 9 7 9 4 8 7 11 0 9 8 11 2 10 6 10 0 9 7 9 4 8 7 13 0 11 8 11 3 10 6 1...

Page 11: ...iring remote control wiring connection 6 Air outlet 7 Suction grille 8 Corner decoration cover 9 Drain hose Accessory Local connection ODø32 Outlet Unit connection ODø26 FXFQ63 80PV9 3D058460B Pipe connection side Drain connection side A Arrow View Note 2 16 M4 Prepared hole Suspention bolt 4 M8 M10 Connection position of branch duct Round shape type Connection position of branch duct Square shape...

Page 12: ...ation cover inner surface 2 In case of using infrared remote control this position will be a signal receiver refer to the drawing of infrared remote control in detail 3 When the temperature and humidity in the ceiling exceed 30 C and RH 80 or the fresh air is inducted into the ceiling or the unit continues 24 hour operation an additional insulation Thickness 10mm or more of glasswool or polyethyle...

Page 13: ...V Systems Indoor Units 11 Indoor Units Round Flow Cassette FXFQ PVE9 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXFQ PV9 4D052237C MODEL NAME A B FXFQ25 80PVE9 246 90 FXFQ100 125PVE9 288 120 ...

Page 14: ...ts Round Flow Cassette FXFQ PVE9 1 6 VRV Systems Indoor Units 12 6 Piping diagram FXFQ PV9 4D024460C Filter Liquid pipe connection port Filter Gas pipe connection port Electronic expansion valve Fan Heat exchanger ...

Page 15: ...witch main sub F1U Fuse F 5A 250V X2M Terminal strip SS2 Selector switch wireless address set HAP Light emitting diode service monitor green Y1E Electronic expansion valve Connector for optional parts K1R Magnetic relay Z1C Ferrite core X24A Connector wireless remote control KPR Magnetic relay M1P Z1F Noise filter X33A Connector adaptor for wiring M1F Motor indoor fan Power supply circuit X35A Con...

Page 16: ...noise FXFQ40PV9 Octave band center frequency Hz Drain up Mic position Over all dB Scale Mode HH H L A 31 0 29 0 27 0 C 36 5 34 8 33 0 B G N is already rectified 4D060233A NOTES 1 Operating conditons Power source 220 240V 50Hz 220V 60Hz Cooling Return air temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB ...

Page 17: ...Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 4 direction discharge 2 Measure in anechoic room 3 Location of microphone 4 Operation noise differs with operation and ambient conditions Octave band sound pressure level dB 0dB 0 0002μbar Approximate threshold hearing for continuous noise FXFQ100PV9 Octave band center frequency Hz Drain up Mic position Over all dB Sc...

Page 18: ......

Page 19: ...without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publication All content is copyrighted by Daikin Europe N V VRV products are not within the scope of the Eurovent certification programme Naamloze Vennootschap Zandvoordestraat 300 B 8400 Oostende Belgium ww...

Reviews: