Types of Product and Operating Noise

FXDQ25SPV1

FXDQ32SPV1

Model

Name

Function

Heat pump / cooling type

Type of unit structure

Split type

Cooling type of condenser

Air cooling type

Type Mode of air supply

Air pipe connecting type

Rated cooling capacity (W)

2200

2800

3600

2500

3200

4000

Rated heating capacity (W)

(Only heat pump type)

Operating noise dB (A)

(Conversion value in a 

fully silenced room)

33

33

34

Model

Name

Type

Function

Heat pump / cooling type

Type of unit structure

Split type

Cooling type of condenser

Air cooling type

Mode of air supply

Air pipe connecting type

Rated cooling capacity (W)

Rated heating capacity (W)

(Only heat pump type)

Operating noise dB (A)

(Conversion value in a 

fully silenced room)

35

37

5600

7100

6300

35

4500

5000

8000

FXDQ20SPV1

FXDQ50SPV1

FXDQ63SPV1

FXDQ40SPV1

Instructions

· 

 

During actual operations, as there is environment 

 

   noise and echo, the noise is usually higher than 

 

   the values shown.

· 

 

With the improvement of technologies, the values 

 

   listed above are subject to change.

· 

 

The operating noise is the value with air suction 

 

   from the back and the static pressure outside the 

 

   unit set to standard.

 

   The operating noise for air suction from below is 

 

   the operating noise with air suction from the back 

 

   plus 5 dB.

 

   However, when installed with the pressure below 

 

   the above static pressure outside the unit, the 

 

   operating noise may be increased by above 5 dB.

After-Sales Service and 

Warranty

WARNING

· 

 

Any repair shall be carried out by your dealer.

 

   Incorrect repair can lead to water leakage, 

 

   electrical shock and fire.

· 

 

Any movement and re-installation shall be 

 

   

carried out by your dealer.

 

   Incorrect installation can lead to water leakage, 

 

   electrical shock and fire.

· 

 

The refrigerant used in the indoor unit is very safe.

    Normally, the refrigerant will not leak out.

 

    However, in case that any refrigerant is leaked 

    out in the room and the refrigerant gas is 

    in contact with such devices as heater, 

    furnace and stove, poisonous gas can 

    be generated.

 

   When any repair for refrigerant leakage is 

    

completed, always request the maintenance 

    

personnel to confirm the status of repair of 

    

the leakage at first, and then operations can 

    

be carried out.

· 

 

When asking for any repair, please provide the 

    following details:

    

· 

 

Model of the air conditioner

    

· 

 

The Serial No. and the date of installation

    

· 

 

Problem – Detailed description (the error code 

        

displayed on the remote control)

    

· 

 

Your name, address and telephone number

· 

 

Repair after the guaranty period

    

Contact your dealer, and if it is repairable, charged 

    

services can be provided.

· 

 

The shortest supply period of the key parts

    

When Daikin stops the production of the air 

    

conditioner of the model, it will supply the key parts 

    

for at least 9 years.

    

Key parts refer to parts which are required for the 

    

product to operate.

· 

 

Maintenance inspection

    

After use for several seasons, as dust is built up in 

    

the unit, the performances of the air conditioner 

    

can be degraded.

    

In addition to the routine maintenance carried out 

    

by yourself, it is recommended to sign a maintenance 

    

and inspection contact with us (charged). For details 

    

on the professional services, please contact your 

    

dealer.

· 

 

Inquiry

    

For details on the after-sales services, please 

    

consult your dealer.

· 

 

When disposing of, moving, re-installing and/or 

    maintaining the product, please firstly recover the 

    refrigerant; and when disposing of the product, 

    it shall be disposed of by a company which has 

    the qualifications to dispose of the waste 

    electrical and electronic products.

· 

 

In the homogeneous materials consisting of the 

    air conditioner, the content of lead, mercury, 

    hexavalent chromium, polybrominated biphenyl, 

    and poly brominated diphenyl ethers is not 

    above 0.1% (mass value), and the content of 

    cadmium is not above 0.01% (mass value).