background image

3

English

    

Maintenance

WARNING

• Only a qualified person is allowed to perform 

maintenance without daily maintenance.

• Before touching any of connection wirings, be 

sure to turn off all power supply switches.

• Do not use flammable materials (e.g., hair-

spray or insecticide) near the product.
Do not clean the product with organic solvents 
such as paint thinner.

The use of organic solvents may cause crack 
damage to the product, electric shocks, or fire.

• Contact professional personnel about attach-

ment of accessories and be sure to use only 
accessories specified by the manufacturer.

If a defect results from your own workmanship, it 
may result in water leaks, electric shock or fire.

CAUTION

• Before cleaning, be sure to stop unit opera-

tion, turn the breaker off or remove the power 
cord.

Otherwise, an electric shock and injury may result.

• Do not wash the air conditioner with water, as 

this may result in electric shocks or fire.

• Consult your dealer regarding cleaning the 

inside of the air conditioner.

Improper cleaning may cause breakage of plastic 
parts, water leakage and other damage as well as 
electric shocks.

• Watch your steps at the time of air filter clean-

ing or inspection.

High-place work is required, to which utmost 
attention must be paid.
If the scaffold is unstable, you may fall or topple 
down, thus causing injury.

Maintenance and inspection

• Clean the drain pan periodically. The drain pipes 

clogged with dust will cause water leakage.

• For cleaning, consult with your Daikin dealer.  

(Before each season when cooling or heating is 
required, clean the air conditioner.)

• If the area around the indoor unit is very dusty, use 

a dust-proof cover (local procurement).

Cleaning the inside of the indoor unit

• It is necessary to clean the inside of the indoor unit 

periodically.
Since the cleaning requires special technologies, 
request a Daikin dealer to clean them.

Daily maintenance:

Cleaning the air filter

Explanation

• Removing the air filter except when cleaning the 

air conditioner may result in accidents.

• When the 

 mark is displayed on the remote 

controller, please clean the filter.

• When the operating time exceeds the designated 

time, this mark will be displayed.

• If using the air conditioner under very dusty envi-

ronment, increase the frequency of air filter clean-
ing.

• When you want to change the setting time until the 

 mark is displayed, consult with your dealer.

(The default factory setting is 2500 hours.)

• There are the following time, display pattern.

1250, 2500, 5000, 10000

1. Remove the air filter.

Information requirements for fan coil units

Item

Symbol

Value

Unit

Cooling capacity 
(sensible)

P

rated, c

A

kW

Cooling capacity (latent)

P

rated, c

B

kW

Heating capacity

P

rated, h

C

kW

Total electric power input

P

elec

D

kW

Sound power level
(per speed setting
if applicable)

L

WA

E

dB

Contact details

DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o.
U Nové Hospody 1/1155, 301 00 Plze

ň

 

Skvr

ň

any, Czech Republic

THE ABOVE TABLE RELATES TO THE MODELS

AND VALUES STATED IN THIS TABLE

Models

A

B

C

D

E

FXDQ15A3VEB

1.5

0.2

1.9

0.071

50

FXDQ20A3VEB

1.9

0.3

2.5

0.071

51

FXDQ25A3VEB

2.1

0.7

3.2

0.071

51

FXDQ32A3VEB

2.6

1

4

0.071

51

FXDQ40A3VEB

3.3

1.2

5

0.078

52

FXDQ50A3VEB

4

1.6

6.3

0.099

53

FXDQ63A3VEB

4.9

2.2

8

0.11

54

Attach the filter to the 
main unit while pushing 
down on the bends.

Main unit

Force

Force

Filter

In case of back side

In case of bottom side

4PEN324678-1F.book  Page 3  Tuesday, October 3, 2017  3:27 PM

Summary of Contents for FXDQ15A3VEB

Page 1: ...OPERATION MANUAL FXDQ15A3VEB FXDQ20A3VEB FXDQ25A3VEB FXDQ32A3VEB FXDQ40A3VEB FXDQ50A3VEB FXDQ63A3VEB System Inverter Air Conditioners...

Page 2: ...Wij danken u voor de aankoop van deze Daikin airconditioner Lees deze bedrijtshandleiding aandachtig door voordat u de airconditioner gebruikt Deze bedieningshandleiding is alleen bedoeld voor de bin...

Page 3: ...fun es do controlador remoto Procedimento de funcionamento Resolu o de Problemas Relativamente ao cart o de garantia obtenha o junto do representante e guarde o com este manual de funcionamento Daiki...

Page 4: ...controller Air filter Air outlet local procurement local procurement Airflow duct In case of suction from bottom side Fan speed can be selected H M L Remote controller Earth wire Connection wire Power...

Page 5: ...ion of noxious gas Do not longer use the air conditioner until a quali fied service person confirms that the leakage has been repaired Consult your local dealer regarding relocation and reinstallation...

Page 6: ...If the area around the indoor unit is very dusty use a dust proof cover local procurement Cleaning the inside of the indoor unit It is necessary to clean the inside of the indoor unit periodically Si...

Page 7: ...your local dealer Continued operation under such circumstances may result in a failure electric shocks or fire haz ards Contact your dealer Phenomenon If a safety device such as a fuse a breaker or a...

Page 8: ...the warranty card Malfunction Inform the staff of the defective details Malfunction code being displayed on the remote controller Name address telephone number Repair where the warranty term is expir...

Page 9: ...4P324678 1F 2017 08 Copyright 2012 Daikin...