background image

 

 

 

Installation and operation manual

 

1

FXCQ20~125M8V3B

VRV System air conditioners

4PW25081-1A

C

ONTENTS

Page

Before installation.............................................................................. 1

Selecting installation site................................................................... 2

Preparations before installation......................................................... 2

Indoor unit installation ....................................................................... 2

Refrigerant piping work ..................................................................... 3

Drain piping work .............................................................................. 3

Electric wiring work ........................................................................... 4

Wiring example and how to set the remote controller ....................... 5

Wiring example ................................................................................. 5

Field setting....................................................................................... 5

Installation of the decoration panel ................................................... 7

Test operation.................................................................................... 7

Maintenance...................................................................................... 7

Disposal requirements ...................................................................... 8

Wiring diagram .................................................................................. 9

B

EFORE

 

INSTALLATION

Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.

Refer to the installation manual of the outdoor unit for items not
described in this manual.

Caution concerning refrigerant series R410A:
The connectable outdoor units must be designed exclusively for
R410A.

Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.

Precautions

Do not install or operate the unit in rooms mentioned below.

Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)

Where corrosive gas like sulphurous gas exists. (Copper tubing
and brazed spots may corrode.)

Where volatile flammable gas like thinner or gasoline is used.

Where machines generating electromagnetic waves exist.
(Control system may malfunction.)

Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories). Also
in vehicles or vessels.

When selecting the installation site, use the supplied paper
pattern for installation.

Do not install accessories on the casing directly. Drilling holes in the
casing may damage electrical wires and consequently cause fire.

Accessories

Check if the following accessories are included with your unit.

Optional accessories

There are two types of remote controllers: wired and wireless.
Select a remote controller according to customers request and
install in an appropriate place.
Refer to catalogues and technical literature for selecting a
suitable remote controller.

Decoration panel.

For the following items, take special care during 
construction and check after installation is finished

FXCQ20M8V3B

FXCQ50M8V3B

FXCQ25M8V3B

FXCQ63M8V3B

FXCQ32M8V3B

FXCQ80M8V3B

FXCQ40M8V3B

FXCQ125M8V3B

VRV System air conditioners

Installation

and operation manual

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

Clamp

1 piece

Also used as packing 

material

Paper pattern for 

installation

1 piece

Drain hose

1 piece

Insulation for fitting

1 each

for gas pipe

for liquid pipe

Screws M5

For paper pattern 

for installation

4 pieces

Washer for hanging 

bracket

8 pieces

Other: installation and operation manual

Tick 

 

when 

checked

Is the indoor unit fixed firmly?

The unit may drop, vibrate or make noise.

Is the gas leak test finished?

It may result in insufficient cooling.

Is the unit fully insulated?

Condensate water may drip.

Does drainage flow smoothly?

Condensate water may drip.

Does the power supply voltage correspond to that shown on the 
name plate?

The unit may malfunction or components may burn out.

Are wiring and piping correct?

The unit may malfunction or components may burn out.

Is the unit safely grounded?

Dangerous at electric leakage.

Is the wiring size according to specifications?

The unit may malfunction or components may burn out.

Is nothing blocking the air outlet or inlet of either the indoor or 
outdoor units?

It may result in insufficient cooling.

Are refrigerant piping length and additional refrigerant charge 
noted down?

The refrigerant charge in the system might not be clear.

Summary of Contents for FXCQ20M8V3B

Page 1: ...INSTALLATION AND OPERATION MANUAL FXCQ20M8V3B FXCQ25M8V3B FXCQ32M8V3B FXCQ40M8V3B FXCQ50M8V3B FXCQ63M8V3B FXCQ80M8V3B FXCQ125M8V3B System air conditioners...

Page 2: ...680 20 20 20 20 C B 6 5 A D 2 7 1 2 3 4 7 2 6 5 2 3 4 5 1 100 1 2 3 4 1 3 6 4 5 2 1 3 4 5 2 1 2 300 mm 1 15 m 600 290 2 3 4 6 5 1 5 6 8 7 9 13 12 10 11 3 4 2 1 100 mm 1 1 7 5 6 2 3 4 P 1 P 2 F 1 F 2 T...

Page 3: ...zgodnie z naszymi instrukcjami 18 sunt n conformitate cu urm torul urm toarele standard e sau alt e document e normativ e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastr...

Page 4: ...cessories are included with your unit Optional accessories There are two types of remote controllers wired and wireless Select a remote controller according to customers request and install in an appr...

Page 5: ...ng Consult the builder for details 3 Install the suspension bolts use either a W3 8 or M10 size bolt Use anchors for existing ceilings and a sunken insert sunken anchors or other field supplied parts...

Page 6: ...to a fire Finally make sure there is no refrigerant gas leak A toxic gas may be released by the refrigerant gas leaking indoor and being exposed to flames from an area heater cooking stove etc Table 1...

Page 7: ...indoor unit as unit A unit B and be sure the terminal board wiring to the outdoor unit and BS unit are properly matched If wiring and piping between the outdoor unit and an indoor unit are mismatched...

Page 8: ...ld damage the entire system 7 Use only specified wires and tightly connect wires to the terminals Be careful that wires do not place external stress on the terminals Keep wiring in neat order so that...

Page 9: ...if installed See note 5 6 Use remote controller sensor only See note 5 6 3 Setting for display of time between 2 filter cleaning display indications Display Do not display 5 Information to I manager...

Page 10: ...ILTERS AND OUTSIDE PANELS How to clean the air filter Clean the air filter when the display shows TIME TO CLEAN AIR FILTER Increase the frequency of cleaning if the unit is installed in a room where t...

Page 11: ...e outdoor unit How to clean the air outlet and outside panels Clean with a soft cloth When it is difficult to remove stains use water or neutral detergent DISPOSAL REQUIREMENTS Dismantling of the unit...

Page 12: ...N OFF BUTTON H1P LIGHT EMITTING DIODE ON RED H2P LIGHT EMITTING DIODE TIMER GREEN H3P LIGHT EMITTING DIODE FILTER SIGN RED H4P LIGHT EMITTING DIODE DEFROST ORANGE SS1 SELECTOR SWITCH MAIN SUB SS2 SELE...

Page 13: ...P1 P2 F1 F2 T1 T2 1 2 3 4 IN D OUT D F1 F2 F1 F2 Control box IN D OUT D F1 F2 F1 F2 Control box L N P1 P2 LN P1 P2 F1 F2 T1 T2 1 3 6 2 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T...

Page 14: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW25081 1A...

Reviews: