• Indoor Units • 2-Way Blow Ceiling Mounted Cassette • FXCQ-MVE9
1
5
• VRV
®
Systems • Indoor Units
12
5
Dimensional drawing & centre of gravity
5 - 1 Dimensional drawing
FXCQ63MVE
3D039407A
NOTES
1
Location of unit's name plates
For main body : Filter install plate inside surface of suction grille
For decoration panel: Panel frame inside surface of suction grille.
2
When installing an optional accessory, refer to the installation
drawings.
3
In case of using wireless remote control, this position will be a
signal receiver. Refer to the drawing of infrared remote control in
detail.
4
If it is assumed that the relative humidity above the ceiling
exceeds 80% stic the additional insulation to the unit.
Insulation: 10 mm thick or more.
Glass fiber of polyethylene foam.
Nr
Name
Description
1
Liquid pipe connection port:
ø 9.5 flare connection
2
Gas pipe connection port:
ø 15.9 flare connection
3
Drain pipe connection port:
VP25 (O.D. ø 32, I.D. ø 25)
4
Power wiring port
5
Air discharge port
6
Air suction grille
7
Port for water supply
8
Drain hose
O.D. ø 32
9
Socket for drain
640 (Cei
ling op
eni
ng)
1309 (Ceiling opening)
520 (Sus
pens
ion pos
iti
on)
1220 (Suspension position)
Branch duct connection
BView
- Require space
or more
or more
or more
Decoration panel
Brand name plate (Note 3)
A View
Fresh air intake
hole (Circumference)
(knock hole)
Suspension bolt
Branch duct connection
FXCQ80-125MVE
3D039409A
NOTES
1
Location of unit's name plates
For main body : Filter install plate inside surface of suction grille
For decoration panel: Panel frame inside surface of suction grille.
2
When installing an optional accessory, refer to the installation
drawings.
3
In case of using wireless remote control, this position will be a
signal receiver. Refer to the drawing of infrared remote control in
detail.
4
If it is assumed that the relative humidity above the ceiling
exceeds 80% stic the additional insulation to the unit.
Insulation: 10 mm thick or more.
Glass fiber of polyethylene foam.
Nr
Name
Description
1
Liquid pipe connection port:
ø 9.5 flare connection
2
Gas pipe connection port:
ø 15.9 flare connection
3
Drain pipe connection port:
VP25 (O.D. ø 32, I.D. ø 25)
4
Power wiring port
5
Air discharge port
6
Air suction grille
7
Port for water supply
8
Drain hose
O.D. ø 32
9
Socket for drain
640 (
C
eili
ng opening)
1309 (Ceiling opening)
520 (
S
us
pens
ion pos
iti
on
)
1220 (Suspension position)
Branch duct connection
BView
- Require space
or more
or more
or more
Decoration panel
Brand name plate (Note 3)
A View
Fresh air intake
hole (Circumference)
(knock hole)
Suspension bolt
Branch duct connection
or less