1. Open the front panel.

Place your fingers on the panel protrusions on 
the left and right sides of the main unit and 
open until the panel stops.
(Follow the same procedure for closing.)

2. Pullout the air filter.

Push up the tab in the center of the air filter 
slightly then pull out in a downward direction.

3. Clean the air filter.

Use vacuum cleaner 

A)

 or wash the air filter 

with water

 B).

A)

Using a vacuum cleaner

B)

Washing with water

When the air filter is very 
dirty, use soft brush and 
neutral detergent

Remove water and dry in the shade.

NOTES

Do not wash the air filter with hot water of more 
than 50°C, as doing so may result in discolora-
tion and/or deformation.

Do not expose it to fire, as doing so may result 
in burning.

4. Attach the air filter.

Once cleaning is done be sure to replace the 
air filter as it was.

5. Shut the front panel.

Refer to item No.1.

6. Press the FILTER SIGN RESET button on 

the remote controller.

The “TIME TO CLEAN AIR FILTER” display 
vanishes.

HOW TO CLEAN THE AIR OUTLET AND 
EXTERIOR

Clean with soft cloth.

When it is difficult to remove stains, use water or 
neutral detergent.

NOTES

Do not use gasoline, benzene, thinner, polish-
ing powder, liquid insecticide. It may cause dis-
coloring or warping.

Do not use water or air of 50°C or higher for 
cleaning air filters.

When the flap is extremely contaminated, 
remove it as below and clean or exchange it.
(Flap for exchange is optional.)

HOW TO CLEAN THE FRONT PANEL

You can remove the front panel to clean it.

NOTES

Hold the front panel firmly so that it does not fall.

Do not use gasoline, benzene, thinner, polish-
ing powder, liquid insecticide. It may cause dis-
coloring or warping.

Do not let the indoor unit get wet. It may cause 
an electric shock or a fire.

Do not scrub firmly when washing the blade 
with water.
The surface sealing may peel off.

Do not use water or air of 50°C or higher for 
cleaning air filters and outside panels.

Make sure the front panel is solidly in place.

1. Open the front panel.

Place your fingers on the panel protrusions on 
the left and right sides of the main unit and 
open until the panel stops.
(Follow the same procedure for closing.)

2. Remove the front panel.

Push the axes on either side of the front panel 
towards the center of the main unit and 
remove.
(You can also remove it by sliding the front panel 
either to the left or right and pulling it forward.)

01_EN_3P156215-11R.fm  Page 3  Wednesday, July 8, 2009  3:56 PM

Summary of Contents for FXAQ20PV1

Page 1: ...ol Italiano Nederlands Portugues Ðóññêèé ÅëëçíéêÜ SYSTEM Air Conditioners OPERATION MANUAL MODELS Wall mounted type FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1 00_CV_3P156215 11R fm Page 1 Monday June 1 2009 1 55 PM ...

Page 2: ...t fail WARNING Failure to follow these instruc tions properly may result in personal injury or loss of life CAUTION Failure to observe these instructions properly may result in property damage or personal injury which may be serious depending on the circumstances After reading keep this manual in a convenient place so that you can refer to it whenever nec essary If the equipment is transferred to ...

Page 3: ...ight MAINTENANCE FOR SERVICE PERSONNEL WARNING Only a qualified person is allowed to per form maintenance without daily mainte nance Before touching any of connection wirings be sure to turn off all power supply switches Do not use flammable materials e g hair spray or insecticide near the product Do not clean the product with organic sol vents such as paint thinner The use of organic solvents may...

Page 4: ...ent NOTES Do not use gasoline benzene thinner polish ing powder liquid insecticide It may cause dis coloring or warping Do not use water or air of 50 C or higher for cleaning air filters When the flap is extremely contaminated remove it as below and clean or exchange it Flap for exchange is optional HOW TO CLEAN THE FRONT PANEL You can remove the front panel to clean it NOTES Hold the front panel ...

Page 5: ...etergent used for cleaning ventilation fans or ovens wait 10 minutes and then rinse with water NOTE Do not wash the air conditioner with hot water of more than 50 C Doing so may result in discol oration or deformation 4 Attach the front panel Set the keys of the front panel into the slots and push them in all the way Close the front panel slowly in this state 01_EN_3P156215 11R fm Page 4 Wednesday...

Page 6: ...3P156215 11R EM09A026 0908 HT 00_CV_3P156215 11R fm Page 2 Monday June 1 2009 1 55 PM ...

Reviews: