background image

5

English

5.

HOW TO CLEAN THE FRONT PANEL

You can remove the front panel to clean it.

NOTES

Hold the front panel firmly so that it does not fall.

Do not use gasoline, benzene, thinner, polishing powder, 
liquid insecticide. It may cause discoloring or warping.

Do not let the indoor unit get wet. It may cause an electric 
shock or a fire.

Do not scrub firmly when washing the blade with water.
The surface sealing may peel off.

Do not use water or air of 50°C or higher for cleaning air fil-
ters and outside panels.

Make sure the front panel is solidly in place.

a.

Open the front panel.

Place your fingers behind panel to the slot on the left and 
right sides of the main unit and open until the panel 
stops.
(Follow the same procedure for closing.)

b.

Remove the front panel.

Push the hooks on either side of the front panel towards 
the side of the unit and remove.
(You can also remove it by sliding the front panel either to 
the left or right and pulling it forward.)

c.

Clean the front panel.

Wipe gently with a soft wet cloth.

Only use neutral cleaning agents.

After washing off, wipe off any excess water and dry in 
a shaded location.

When very grimy

Directly apply the type of detergent used for cleaning 
ventilation fans or ovens, wait 10 minutes, and then 
rinse with water.

NOTE

Do not wash the air conditioner with hot water of more than 
50°C. Doing so may result in discoloration or deformation.

d.

Attach the front panel.

Set the hooks of the front panel into the slots and push 
them in all the way.
Close the front panel slowly in this state.

6.

MAINTENANCE 
(FOR SERVICE PERSONNEL)

WARNING

Only a qualified person is allowed to perform mainte-
nance. (Except daily maintenance.)

Before touching any of connection wirings, be sure to 
turn off all power supply switches.

Contact professional personnel about attachment of 
accessories and be sure to use only accessories 
specified by the manufacturer.

If a defect results from your own workmanship, it may result 
in water leaks, electric shock or fire.

Do not use flammable materials (e.g., hairspray or 
insecticide) near the product.
Do not clean the product with organic solvents such 
as paint thinner.

The use of organic solvents may cause crack damage to 
the product, electric shocks, or fire.

Consult your dealer regarding cleaning the inside of 
the air conditioner.

Improper cleaning may cause breakage of plastic parts, 
water leakage and other damage as well as electric 
shocks.

CAUTION

Before cleaning, be sure to stop unit operation, turn 
the power circuit breaker off or remove the power 
cord.

Otherwise, an electric shock and injury may result.

Do not wash the air conditioner with water, as this may 
result in electric shocks or fire.

Watch your steps at the time of air filter cleaning or 
inspection.

High-place work is required, to which utmost attention 
must be paid.
If the scaffold is unstable, you may fall or topple down, thus 
causing injury.

NOTE

Do not remove the air filter except when cleaning.
This may cause breakage.

7.

SOUND PRESSURE LEVEL

Sound pressure level is less than 70 dB(A).

4PEN494113-1.book  Page 5  Thursday, October 26, 2017  10:28 AM

Summary of Contents for FXAQ15AUV1B

Page 1: ...OPERATION MANUAL FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B System air conditioners ...

Page 2: ...rant pipe transmission wiring Remote controller option Horizontal flaps vertical air outlet direction adjustment flaps auto Vertical flaps horizontal air outlet direction adjustment flaps manual Air outlet Earth wire Conducts electricity from the unit into the ground to prevent electric shock Indoor unit model name under the panel Power supply wiring 1 GWP global warming potential Periodical inspe...

Page 3: ...r more if an automatic restart control is provided against power failure and the power is recovered the fan will rotate suddenly and may cause injury Do not use the air conditioner in the atmosphere contaminated with oil vapor such as cooking oil or machine oil vapor Oil vapor may cause crack damage to the air conditioner electric shocks or a fire Do not use flammable materials e g hairspray or in...

Page 4: ...r from the indoor or outdoor unit will affect them Turn off the power when the air conditioner is not used for long periods of time Otherwise the air conditioner may get hot or catch on a fire due to dust accumulation Do not place objects in direct proximity of the out door unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter ...

Page 5: ...frequency of cleaning if the unit is installed in a room where the air is extremely contaminated If the dirt becomes impossible to clean change the air filter Air filter for exchange is optional a Open the front panel Place your fingers on the panel protrusions on the left and right sides of the main unit and open until the panel stops Follow the same procedure for closing b Pullout the air filter...

Page 6: ...l Set the hooks of the front panel into the slots and push them in all the way Close the front panel slowly in this state 6 MAINTENANCE FOR SERVICE PERSONNEL WARNING Only a qualified person is allowed to perform mainte nance Except daily maintenance Before touching any of connection wirings be sure to turn off all power supply switches Contact professional personnel about attachment of accessories...

Page 7: ...he dismantling of the product treatment of the refrigerant of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent poten tial negative consequences for the environment...

Page 8: ...4P494113 1 2017 08 Copyright 2017 Daikin ...