Daikin FWB-CT Technical Manual Download Page 9

uT66002760-02

All copying, even partial, of this manual is strictly forbidden

9

» 4 pipes 

FWB-C

04

05

06

08

Speed

min

med

max

min

med

max

min

med

max

min

med

max

Declared speed

2,5,7

1,5,7

1,6,7

1,4,7

Rated air flow

 (E)

m³/h

109

243

270

170

272

336

195

357

398

302

524

642

Available static pressure

 (E)

Pa

10

50

63

19

50

77

19

50

63

17

50

75

Power input

 (E)

W

24

57

82

34

69

106

34

85

106

76

143

192

Maximum current absorption

A

0,40

0,56

0,56

1,10

Total cooling capacity

(1)(E)

kW

0,92

1,70

1,86

1,26

1,88

2,24

1,57

2,67

2,93

1,89

3,13

3,64

Sensible cooling capacity

(1)(E)

kW

0,61

1,20

1,31

0,88

1,33

1,57

1,07

1,84

2,01

1,41

2,35

2,78

FCEER class

 (E)

D

E

Water flow

(2)

l/h

160

302

333

221

335

404

274

473

522

339

562

656

Water pressure drop

(2)(E)

kPa

2

5

6

3

6

8

3

7

9

3

8

11

Heating capacity

(3)(E)

kW

1,14

1,93

2,06

1,55

2,07

2,32

2,09

3,09

3,29

2,80

3,82

4,24

FCCOP class

 (E)

C

D

C

D

Water flow

(3)

l/h

100

169

180

136

181

204

183

271

288

245

334

371

Water pressure drop

(3)(E)

kPa

1

2

3

2

3

3

2

3

4

3

5

6

Additional coil  - number of rows

1

1

1

1

Total sound power level

(4)

dB(A)

28

49

52

39

50

54

39

50

54

38

52

58

Inlet + radiated sound power level

(4)(E)

dB(A)

26

47

50

37

48

52

37

48

52

36

50

56

Outlet sound power level

(4)(E)

dB(A)

25

46

49

36

47

51

37

47

51

35

49

55

Water content - additional coil

dm³

0,47

0,47

0,59

0,59

Power supply cable type

N07V-K

Cross-section area of power cables

(5)

mm²

1,00

1,00

1,00

1,50

Safety fuse F

A

1

1

1

2

Fuses type

gG

FWB-C

10

11

15

17

Speed

min

med

max

min

med

max

min

med

max

min

med

max

Declared speed

1,6,7

1,6,7

5,6,7

5,6,7

Rated air flow

 (E)

m³/h

333

683

755

333

683

755

1050

1163

1289

1050

1163

1289

Available static pressure

 (E)

Pa

12

50

61

12

50

61

40

50

60

40

50

60

Power input

 (E)

W

76

167

192

76

167

192

235

280

332

235

280

332

Maximum current absorption

A

1,10

1,10

2,10

2,10

Total cooling capacity

(1)(E)

kW

2,22

4,20

4,60

2,44

4,76

5,20

6,15

6,66

7,21

6,91

7,49

8,12

Sensible cooling capacity

(1)(E)

kW

1,60

3,07

3,36

1,70

3,31

3,62

4,51

4,88

5,29

4,83

5,23

5,67

FCEER class

 (E)

D

Water flow

(2)

l/h

394

749

822

432

846

925

1095

1191

1295

1225

1333

1448

Water pressure drop

(2)(E)

kPa

2

7

8

3

10

12

13

16

18

20

23

26

Heating capacity

(3)(E)

kW

3,40

5,17

5,45

3,40

5,17

5,45

6,42

6,73

7,06

6,42

6,73

7,06

FCCOP class

 (E)

D

Water flow

(3)

l/h

297

452

477

297

452

477

562

590

618

562

590

618

Water pressure drop

(3)(E)

kPa

6

13

14

6

13

14

19

21

22

19

21

22

Additional coil  - number of rows

1

1

1

1

Total sound power level

(4)

dB(A)

38

55

58

38

55

58

61

63

69

61

63

69

Inlet + radiated sound power level

(4)(E)

dB(A)

36

53

56

36

53

56

59

61

67

59

61

67

Outlet sound power level

(4)(E)

dB(A)

35

52

55

35

52

55

58

60

66

58

60

66

Water content - additional coil

dm³

0,97

0,97

0,97

0,97

Power supply cable type

N07V-K

Cross-section area of power cables

(5)

mm²

1,50

1,50

1,50

1,50

Safety fuse F

A

2

2

2

2

Fuses type

gG

(1)  Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) according to EN1397:2015

(2)  Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity)

(3)  Water temperature 65°C / 55°C, air temperature 20°C

(4)  Sound power measured according to standards ISO 3741 and ISO 3742

(5)  The shown section is to be considered as the minimum recommended section. The cables must be chosen in compliance with CEI - UNEL 35024/1. standard.

(E)  EUROVENT certified data

Power supply 230-1-50 (V-ph-Hz)

Summary of Contents for FWB-CT

Page 1: ...2 pipes systems 4 pipes systems Centrifugal fan Ducted FEATURES Multi speed motor Heat exchanger up to 4 rows Water connections ABS centrifugal fans Medium static pressure ducted fan coil units 2 8 k...

Page 2: ......

Page 3: ...S p 4 STRUCTURE p 4 ELECTRIC MOTOR p 4 AIR FILTER p 4 2 1 AIR INTAKE p 4 HEAT EXCHANGER p 4 FANS p 4 3 INSTALLATION p 5 3 1 INSTALLATION REQUIREMENTS p 5 3 2 ASSEMBLY OF UNITS p 6 4 AVAILABLE ACCESSOR...

Page 4: ...MPONENTS STRUCTURE Built from galvanised steel sheet heat and sound insulated by means of Class 1 self extinguishing panels Reduced height to facilitate installation in a horizontal position in a fals...

Page 5: ...may be easily set and which is suitable for taking temperature readings where applicable Avoid positions directly exposed to sunlight or direct cur rents of hot or cold air and make sure there are no...

Page 6: ...F UNITS Mounting the unit Insert the vibration dampers provided in the 4 slots indicated for ceiling installation Fasten the base unit to the ceiling or wall using at least 4 of the 8 slots provided I...

Page 7: ...ical heating elements EH Heating element with installation kit relay box and safety devices Accessories EPIMSB6 Power interface for connecting in parallel up to 4 fan coil units to the one controller...

Page 8: ...1050 1163 1289 1050 1163 1289 Available static pressure E Pa 12 50 61 12 50 61 40 50 60 40 50 60 Power input E W 76 167 192 76 167 192 235 280 332 235 280 332 Maximum current absorption A 1 10 1 10 2...

Page 9: ...83 755 333 683 755 1050 1163 1289 1050 1163 1289 Available static pressure E Pa 12 50 61 12 50 61 40 50 60 40 50 60 Power input E W 76 167 192 76 167 192 235 280 332 235 280 332 Maximum current absorp...

Page 10: ...43 8 40 2 34 2 25 5 49 53 2 50 9 47 2 42 8 39 2 33 2 24 5 max 7 56 60 2 57 9 54 2 49 8 46 2 40 2 31 5 55 59 2 56 9 53 2 48 8 45 2 39 2 30 5 10 min 1 36 40 2 37 9 34 2 29 8 26 2 20 2 0 0 35 39 2 36 9...

Page 11: ...7 2 42 8 39 2 33 2 24 5 max 7 56 60 2 57 9 54 2 49 8 46 2 40 2 31 5 55 59 2 56 9 53 2 48 8 45 2 39 2 30 5 10 min 1 36 40 2 37 9 34 2 29 8 26 2 20 2 0 0 35 39 2 36 9 33 2 28 8 25 2 19 2 0 0 med 6 53 57...

Page 12: ...e 2 Water connections additional heat exchanger 1 2 female 3 Condensate discharge diameter 17 FWB C 04 05 06 08 A mm 758 758 968 968 C mm 677 677 887 887 D mm 648 648 858 858 E mm 707 707 917 917 300...

Page 13: ...4 female 2 Water connections additional heat exchanger 1 2 female 3 Condensate discharge diameter 17 300 300 140 100 3 2 2 1 21 227 33 15 D 15 C 685 745 120 26 155 26 E A 385 503 596 618 43 113 220 21...

Page 14: ...y at least 3 mm and an adequate protection fuse F Electrical intakes are shown on the rating labels on the units During installation strictly abide by the indications on the wir ing diagram for the un...

Page 15: ...round N Neutral F Fuse not provided IL Circuit breaker not supplied Wirings made by supplier WH White BK Black max speed BU Blue BN Brown GY Grey GN Green YE Yellow RD Red min speed GYNE Yellow green...

Page 16: ...L Phase PE Ground N Neutral F Fuse not provided IL Circuit breaker not supplied Wirings made by supplier WH White BK Black max speed BU Blu medium speed BN Brown GY Grey GN Green YE Yellow RD Red min...

Page 17: ...UT66002760 02 All copying even partial of this manual is strictly forbidden 17 Electrical connection FWB C 04 FWEC1A valve Electrical connection FWB C 05 11 FWEC1A valve...

Page 18: ...FWB C Technical manual 18 Electrical connection FWB C 05 11 FWEC1A valve Electrical connection FWB C 04 FWEC2A 3A valve...

Page 19: ...UT66002760 02 All copying even partial of this manual is strictly forbidden 19 Electrical connection FWB C 05 11 FWEC2A 3A valve Electrical connection FWB C 15 17 FWEC2A 3A valve...

Page 20: ...FWB C Technical manual 20 Electrical connection FWB C 04 FWEC1A valve heating element Electrical connectionFWB C 05 11 FWEC1A valve heating element...

Page 21: ...66002760 02 All copying even partial of this manual is strictly forbidden 21 Electrical connection FWB C 15 17 FWEC1A valve heating element Electrical connection FWB C 04 FWEC2A 3A valve heating eleme...

Page 22: ...FWB C Technical manual 22 Electrical connection FWB C 05 11 FWEC2A 3A valve heating element Electrical connection FWB C 15 17 FWEC2A 3A valve heating element...

Page 23: ...wall mounted microprocessor split controller with display FWECS controller is a system composed of Circuit board comprising the power circuit the microprocessor system and the removable screw connect...

Page 24: ...xchanger or additional heat exchanger 2 way motor driven modulating valve pressure independent complete with hydraulic kit Itcontrolstheroomtemperaturebystoppingthewaterflowthroughtheheatexchanger Wit...

Page 25: ...rom the power supply by setting the main switch on 0 OFF To clean the air filter proceed as follows 1 Access the unit via the inspection panel and take out the air filter as shown in Air filter 2 If t...

Page 26: ...FWB C Technical manual 26 Standard air intake...

Page 27: ......

Page 28: ...Zandvoordestraat 300 B 8400 Oostende Belgium...

Reviews: