11 ACCESSORIES

FWEC1A wall-mounted microprocessor control

having the following main features:

•  Room air temperature reading and adjustment

•  Water temperature reading (water probe as an optional)

•  Manual and automatic adjustment of fan speed

•  Manual and automatic switching of heating and cooling mode depending on the water temperature within the heat exchanger or on the room temperature, with 

a neutral zone that can be selected in the range from 2° to 5°C.

The controller is equipped with a large display (3”) to show and set all the functions of the unit.

Using the installation kit available FWEC1A can be mounted on the unit.

FWEC2A - wall-mounted microprocessor control

having the following main features:

•  Room air temperature reading and adjustment

•  Room humidity reading and adjustment

•  Water temperature reading (water probe as an optional)

•  Manual and automatic adjustment of fan speed

•  Manual and automatic switching of heating and cooling mode depending on the water temperature within the heat exchanger or on the room temperature, with 

a neutral zone that can be selected in the range from 2° to 5°C.

•  Serial port for Bus connection

The controller is equipped with a large display (3”) to show and set all the functions of the unit.

Using the installation kit available, FWEC2A can be mounted on the unit.

FWEC3A- wall-mounted microprocessor control

having the following main features:

•  Room air temperature reading and adjustment

•  Room humidity reading and adjustment

•  Water temperature reading (water probe as an optional)

•  Manual and automatic adjustment of fan speed

•  Manual and automatic switching of heating and cooling mode depending on the water temperature within the heat exchanger or on the room temperature, with 

a neutral zone that can be selected in the range from 2° to 5°C.

•  Clock and hourly timer-programmed operation

•  2 Analogue outputs for controlling modulating evices -10V

•  2 Digital outputs for controlling (On/Off) external devices (novoltage contacts)

•  Serial port for Bus connection

The controller is equipped with a large display (3”) to show and set all the functions of the unit. Using the installation kit available, FWEC3A can be mounted on 

the unit.

FWECS - wall-mounted microprocessor split controller with display

FWECS controller is a system composed of:

•  Circuit board comprising the power circuit, the microprocessor system and the removable screw connectors for the connection of the inlet and outlet devices;

•  User interface comprising a graphic display and a keyboard (six keys) provided with clock and sensor to read the ambient temperature.

Main functions:

•  Room air temperature reading and adjustment

•  Room humidity reading and adjustment

•  Water temperature reading (water sensor as an optional)

•  Manual/automatic regulation of the fan speed with ON -OFF step and modulating control

•  Automatic adjustment of valve opening with ON/OFF and modulating controller

•  Manual and automatic switching of heating and cooling mode depending on the water temperature within the heat exchanger or on the room temperature, 

with a selectable neutral zone

•  Clock and hourly timer-programmed operation

•  3 Analogue outputs for controlling modulating devices -10V

•  Economy function and minimum temperature

•  1 Digital outputs for controlling (On/Off) external devices (novoltage contacts)

•  Serial port for RS485 connection

•  Serial port for OC connection

•  3 digital inputs for ON-OFF, Economy, Operating mode remote setting

Operating mode

The controller is provided with a programmable display that allows you to view and set the hydronic unit functions by means of the specific interface with parameter 

description.

FWTSKA - water temperature sensor for microprocessor controls model FWECS, FWEC1A/2A/3A

Directly connected to the microprocessor controllers FWECS and FWEC1A/2A/3A to measure the water temperature through the heat exchanger.

If the temperature registered is lower than 17 °C the unit works in cooling mode and the temperature range of the control panel will be referred to the cooling mode 

(19/31 °C); if the temperature registered is higher than 37 °C the unit works in heating mode and the temperature range of the control panel will be referred to the 

heating mode (14/26 °C). If the temperature registered is between 17 °C e 37 °C the control panel will disable the unit operation.

FWHSKA - Humidity sensor for FWECS, FWEC1A/2A/3A) microprocessor controller

Directly connected to the microprocessor controllers FWECS and FWEC1A/2A/3A, it enables the control of the heating element ventilation (if present, as support in 

heating mode) and the automatic cooling/heating changeover according to the water temperature.

Summary of Contents for FWB-CT

Page 1: ...2 pipes systems 4 pipes systems Centrifugal fan Ducted FEATURES Multi speed motor Heat exchanger up to 4 rows Water connections ABS centrifugal fans Medium static pressure ducted fan coil units 2 8 k...

Page 2: ......

Page 3: ...S p 4 STRUCTURE p 4 ELECTRIC MOTOR p 4 AIR FILTER p 4 2 1 AIR INTAKE p 4 HEAT EXCHANGER p 4 FANS p 4 3 INSTALLATION p 5 3 1 INSTALLATION REQUIREMENTS p 5 3 2 ASSEMBLY OF UNITS p 6 4 AVAILABLE ACCESSOR...

Page 4: ...MPONENTS STRUCTURE Built from galvanised steel sheet heat and sound insulated by means of Class 1 self extinguishing panels Reduced height to facilitate installation in a horizontal position in a fals...

Page 5: ...may be easily set and which is suitable for taking temperature readings where applicable Avoid positions directly exposed to sunlight or direct cur rents of hot or cold air and make sure there are no...

Page 6: ...F UNITS Mounting the unit Insert the vibration dampers provided in the 4 slots indicated for ceiling installation Fasten the base unit to the ceiling or wall using at least 4 of the 8 slots provided I...

Page 7: ...ical heating elements EH Heating element with installation kit relay box and safety devices Accessories EPIMSB6 Power interface for connecting in parallel up to 4 fan coil units to the one controller...

Page 8: ...1050 1163 1289 1050 1163 1289 Available static pressure E Pa 12 50 61 12 50 61 40 50 60 40 50 60 Power input E W 76 167 192 76 167 192 235 280 332 235 280 332 Maximum current absorption A 1 10 1 10 2...

Page 9: ...83 755 333 683 755 1050 1163 1289 1050 1163 1289 Available static pressure E Pa 12 50 61 12 50 61 40 50 60 40 50 60 Power input E W 76 167 192 76 167 192 235 280 332 235 280 332 Maximum current absorp...

Page 10: ...43 8 40 2 34 2 25 5 49 53 2 50 9 47 2 42 8 39 2 33 2 24 5 max 7 56 60 2 57 9 54 2 49 8 46 2 40 2 31 5 55 59 2 56 9 53 2 48 8 45 2 39 2 30 5 10 min 1 36 40 2 37 9 34 2 29 8 26 2 20 2 0 0 35 39 2 36 9...

Page 11: ...7 2 42 8 39 2 33 2 24 5 max 7 56 60 2 57 9 54 2 49 8 46 2 40 2 31 5 55 59 2 56 9 53 2 48 8 45 2 39 2 30 5 10 min 1 36 40 2 37 9 34 2 29 8 26 2 20 2 0 0 35 39 2 36 9 33 2 28 8 25 2 19 2 0 0 med 6 53 57...

Page 12: ...e 2 Water connections additional heat exchanger 1 2 female 3 Condensate discharge diameter 17 FWB C 04 05 06 08 A mm 758 758 968 968 C mm 677 677 887 887 D mm 648 648 858 858 E mm 707 707 917 917 300...

Page 13: ...4 female 2 Water connections additional heat exchanger 1 2 female 3 Condensate discharge diameter 17 300 300 140 100 3 2 2 1 21 227 33 15 D 15 C 685 745 120 26 155 26 E A 385 503 596 618 43 113 220 21...

Page 14: ...y at least 3 mm and an adequate protection fuse F Electrical intakes are shown on the rating labels on the units During installation strictly abide by the indications on the wir ing diagram for the un...

Page 15: ...round N Neutral F Fuse not provided IL Circuit breaker not supplied Wirings made by supplier WH White BK Black max speed BU Blue BN Brown GY Grey GN Green YE Yellow RD Red min speed GYNE Yellow green...

Page 16: ...L Phase PE Ground N Neutral F Fuse not provided IL Circuit breaker not supplied Wirings made by supplier WH White BK Black max speed BU Blu medium speed BN Brown GY Grey GN Green YE Yellow RD Red min...

Page 17: ...UT66002760 02 All copying even partial of this manual is strictly forbidden 17 Electrical connection FWB C 04 FWEC1A valve Electrical connection FWB C 05 11 FWEC1A valve...

Page 18: ...FWB C Technical manual 18 Electrical connection FWB C 05 11 FWEC1A valve Electrical connection FWB C 04 FWEC2A 3A valve...

Page 19: ...UT66002760 02 All copying even partial of this manual is strictly forbidden 19 Electrical connection FWB C 05 11 FWEC2A 3A valve Electrical connection FWB C 15 17 FWEC2A 3A valve...

Page 20: ...FWB C Technical manual 20 Electrical connection FWB C 04 FWEC1A valve heating element Electrical connectionFWB C 05 11 FWEC1A valve heating element...

Page 21: ...66002760 02 All copying even partial of this manual is strictly forbidden 21 Electrical connection FWB C 15 17 FWEC1A valve heating element Electrical connection FWB C 04 FWEC2A 3A valve heating eleme...

Page 22: ...FWB C Technical manual 22 Electrical connection FWB C 05 11 FWEC2A 3A valve heating element Electrical connection FWB C 15 17 FWEC2A 3A valve heating element...

Page 23: ...wall mounted microprocessor split controller with display FWECS controller is a system composed of Circuit board comprising the power circuit the microprocessor system and the removable screw connect...

Page 24: ...xchanger or additional heat exchanger 2 way motor driven modulating valve pressure independent complete with hydraulic kit Itcontrolstheroomtemperaturebystoppingthewaterflowthroughtheheatexchanger Wit...

Page 25: ...rom the power supply by setting the main switch on 0 OFF To clean the air filter proceed as follows 1 Access the unit via the inspection panel and take out the air filter as shown in Air filter 2 If t...

Page 26: ...FWB C Technical manual 26 Standard air intake...

Page 27: ......

Page 28: ...Zandvoordestraat 300 B 8400 Oostende Belgium...

Reviews: