9
■
English
Indoor Unit Installation
4-2� Installation
Exposed installation
1) Secure the indoor unit
<Floor Installation>
• Secure the indoor unit using 6 screws. (2 screws for floor and 4 screws for rear wall)
Casing
2 screws
3/16” × 1” (M4 × 25mm) (
field supply
)
5 screws
3/16” × 1” (M4 × 25mm)
(
field supply
)
Mounting plate
A
Molding
The mounting
plate should be
installed on a wall
which can support
the weight of the
indoor unit.
A
4 screws
3/16” × 1” (M4 × 25mm) (field supply)
<Wall Installation>
• Secure the
A
mounting plate using 5 screws.
• Secure the indoor unit using 4 screws for rear wall.
Casing
2 screws
3/16” × 1” (M4 × 25mm) (
field supply
)
5 screws
3/16” × 1” (M4 × 25mm)
(
field supply
)
Mounting plate
A
Molding
The mounting
plate should be
installed on a wall
which can support
the weight of the
indoor unit.
A
4 screws
3/16” × 1” (M4 × 25mm) (field supply)
2) Once refrigerant piping and drain piping connections are complete, fill in the gap of the through hole with putty.
A gap can lead to condensation on the refrigerant pipe, and drain pipe, and the entry of insects into the pipes�
3) Attach and screws the each side casings and upper casing in their original position using 7 screws.
4) Attach the front grill in their original position using 4 screws.
5) Attach the front panel in their original position.
• Attach the string to the right, inner-side of the front grille.
• Close the front panel and slide until the stoppers click outside.
Slide the stoppers