![background image](http://html1.mh-extra.com/html/daikin/fvks25bavmb/fvks25bavmb_service-manual_2459592016.webp)
Removal of the Fan Rotor / Fan Motor
Si06-763
14
Removal Procedure
4
Loosen the 6 screws (3
for the upper side
motor and 3 for the
bottom one) to remove
the fan motors.
Short lead wire: for the upper
fan motor
Long lead wire: for the
bottom fan motor
Mounting screw M4 × 16
5
Remove the motors
and cross flow fans.
Loosen the fixing screw to
separate the fan and motor.
6
To remove the casing,
loosen the 4 screws at
front side and the other
4 screws at rear side.
Casing mounting screw
Front: M4 × 16
Rear: M4 × 14
Condition : Casing
Protruded : Not to be removed
Semi-sink : To be removed
Sink : Not to be removed
Step
Procedure
Points
(R2640)
(R2641)
(R2642)