background image

11

English

6. Attach the suction grille.

Attach the suction grille in the reverse order 
mentioned in the clause 2.

7. Close the suction grille.

Simultaneously slide the 2 knobs in the reverse 
order mentioned in the clause 1, slowly lift the 
suction grille and securely fix it.

HOW TO CLEAN OUTSIDE PANELS AND 
REMOTE CONTROLLER

Wipe them with a dry soft cloth.

When the stain cannot be wiped off, dip the cloth 
in the neutral detergent diluted with water and 
twist the cloth. 
After wiping off stain with this cloth, wipe them 
with dry cloth.

NOTE 

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

• Do not wash them with warm water of 50°C or 

higher.
It may cause discoloration and deformation.

CLEANING BEFORE AND AFTER SEA-
SONAL USE

WHAT TO DO WHEN START UP AFTER A 
LONG STOP

Confirm the following.

Check that the air inlet and outlet of indoor and 
outdoor unit are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage of the 
devices.

Clean the air filter.

After cleaning the air filter, make sure to attach it.
(Refer to 

“8. MAINTENANCE”

 on page 9.)

For information on how to install, remove, or clean 
a optional sold air filter, refer to the user’s manual 
attached to the air filter.

Turn off the indication “

” or “Time to clean fil-

ter” displayed on the remote controller after turn-
ing on the power.

For details, refer to the operation manual attached 
to the remote controller.
The indication can be turned off whether in oper-
ation or at stop. 

Turn on the power circuit breaker at least 6 
hours before operation.

This is required in order to activate the air condi-
tioner smoothly, and to protect the air conditioner.

The display on the remote controller will be shown 
when the power circuit breaker is turned on.

HEATING OPERATION within 6 hours after 
power is supplied to the air conditioner.

Some model series perform the following operation 
to protect the devices.
If the HEATING OPERATION is performed within 6 
hours after power is supplied to the air conditioner, 
the indoor fan stops for about 10 minutes during the 
outdoor unit operation to protect the devices.
The above operation is performed not only for instal-
lation, but every time the power circuit breaker is 
turned off/on.
For comfortable use, do not turn off the power circuit 
breaker during seasonal use of the HEATING 
OPERATION.

WHAT TO DO WHEN STOPPING THE AIR 
CONDITIONER FOR A LONG PERIOD

Turn on FAN OPERATION for a half day on the 
fine day and dry the indoor unit.

This can prevent the causes of mould.

Turn off the power circuit breaker.

During the power circuit breaker is turned on, 
some watts of electricity is being used even if the 
air conditioner is not operating.
Turn off the power circuit breaker for saving 
energy.

The display on the remote controller will vanish 
when the power circuit breaker is turned off. 

Clean the air filter.

Be sure to replace the air filter to its original place 
after cleaning.
(Refer to 

“8. MAINTENANCE”

 on page 9.)

For information on how to install, remove, or clean 
an optional sold air filter, refer to the user’s manual 
attached to the air filter.

NOTE 

The inside of the air conditioner may become con-
taminated after several seasons of use, potentially 
causing performance degradation and water leak-
age.
Ask your local dealer for details on cleaning the 
inside of the indoor unit. This operation requires a 
qualified service person.

01_EN_3P170549-16W.fm  Page 11  Thursday, February 20, 2014  5:28 PM

Summary of Contents for FUQ71CVEB

Page 1: ...MANUAL MODELS 4 Way Blow Ceiling Suspended type SPLIT SYSTEM VRV SYSTEM FUQ71CVEB FXUQ71AVEB FUQ100CVEB FXUQ100AVEB FUQ125CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugu s T rk e 00...

Page 2: ...rdelo para futuras consultas Asimismo aseg rese de entregar este manual de instrucciones a un nuevo usuario Debido a que este manual de instrucciones est dedi cado a la unidad interior deber consultar...

Page 3: ...tes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especial izadas para su r...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched so...

Page 6: ...he control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove the...

Page 7: ...s a customized control system ask your local dealer for the operation that corre sponds to your system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Page 8: ...t bulb temperature The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ Read the operation manual attached to the out door unit Regarding places for installation Istheairco...

Page 9: ...is used to prevent the dis charge of melt water The remote controller displays the fan speed that is set When the outdoor temperature is high it takes some time until the indoor temperature reaches th...

Page 10: ...r the indoor temperature and humidity first use the COOLING OPERATION to lower the indoor temperature and then use the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the ind...

Page 11: ...conditioner It may decrease the effect or stop the operation Adjust the room temperature properly for a com fortable environment Avoid excessive heating or cooling Not doing so wastes electricity When...

Page 12: ...r filter It indicates after running for a certain time NOTE You may change the time of indication or Time to clean filter If the indoor unit is used in a space where the air is more contaminated ask y...

Page 13: ...ched to the indoor unit Refer to the figure shown below Suction grille Strap Knob Knob 2 Open the suction grille to 45 and lift it Then unhook it from the place to hook 3 places 3 Take out the air fil...

Page 14: ...order to activate the air condi tioner smoothly and to protect the air conditioner The display on the remote controller will be shown when the power circuit breaker is turned on HEATING OPERATION wit...

Page 15: ...installation but every time the power cir cuit breaker is turned off on 9 NOT MALFUNCTION OF THE AIR CONDITIONER For comfortable use do not turn off the power circuit breaker during seasonal use of t...

Page 16: ...unit Ask your local dealer for details on cleaning the indoor unit This cleaning requires a qualified service person Check the usage environment When the air conditioner is changed over to the HEATIN...

Page 17: ...vers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove the obstacle and make it well venti la...

Page 18: ...his time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditio...

Page 19: ...3P170549 16W EM12A001A 1404 HT 00_CV_3P170549 16W_01 fm Page 2 Saturday February 15 2014 6 19 PM...

Reviews: