The airflow direction becomes horizontal. (The 
remote controller displays the airflow direction 
that is set.)

During or after the DEFROST OPERATION, white 
mist comes out from the air inlet or outlet of the air 
conditioner. 
(Refer to 

“VI.”

 on page 13.)

A hissing and “Shuh” sound may be heard during 
this particular operation.

Regarding outside air temperature and heat-
ing capacity

The heating capacity of the air conditioner 
declines as the outside air temperature falls. 
In such a case, use the air conditioner in combi-
nation with other heating systems.
(When a combustion appliance is used, ventilate 
the room regularly.)
Do not use the combustion appliance where the air 
from the air conditioner is blown directly toward it.

When the warm air stays under the ceiling and 
your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room).
For details, consult your local dealer.

When the indoor temperature exceeds the set 
temperature, the indoor unit discharges a gentle 
breeze (switches to gentle wind). The airflow 
direction becomes horizontal. (The remote con-
troller displays the fan speed and airflow direction 
that are set.) 

CHARACTERISTICS OF THE PROGRAM 
DRY OPERATION

This operation lowers the humidity without lower-
ing the indoor temperature. The indoor tempera-
ture when the operation button is pressed will be 
the set temperature. At this time, the fan speed 
and temperature are set automatically, so the 
remote controller does not display the fan speed 
and set temperature.
To efficiently lower the indoor temperature and 
humidity, first use the COOLING OPERATION to 
lower the indoor temperature, and then use the 
PROGRAM DRY OPERATION. When the indoor 
temperature is lowered, airflow from the indoor 
unit may stop.

When operating continuously at downward airflow 
direction, air blows in the automatic set direction 
for a period of time to prevent condensation on the 
horizontal blades. (The remote controller displays 
the airflow direction that is set.)

If the PROGRAM DRY OPERATION is used when 
the indoor temperature is low, frost forms the heat 
exchanger of the indoor unit. In this case, the air 
conditioner automatically switches to the 
DEFROST OPERATION for a while.
The low fan speed or a gentle wind is used to pre-
vent the discharge of melt water.

SOUND PRESSURE LEVEL

Sound pressure level is less than 70 dB(A).

AIRFLOW DIRECTION ADJUST

Airflow direction adjust can be individually set for 
each air outlet. (BRC1E52 only)

Check the air outlet identification mark (refer to 
page 5), and use the remote controller to set the 
airflow direction. (For details, refer to the opera-
tion manual attached to the remote controller.)

The horizontal blades at the air outlet are closed 
while the indoor unit stops.

AIRFLOW DIRECTION ADJUST

Press the AIRFLOW DIRECTION ADJUST/SET-
TING button to adjust the airflow direction. 

The AIRFLOW DIRECTION dis-
play swings as shown left and the 
airflow direction continuously var-
ies. (Automatic swing setting)

Press AIRFLOW DIRECTION 
ADJUST/SETTING button to 
select the air direction of your 
choice.

The AIRFLOW DIRECTION dis-
play stops swinging and the air-
flow direction is fixed (Fixed 
airflow direction setting).

Up and down adjustment

swing

01_EN_3P170549-16W.fm  Page 7  Thursday, February 20, 2014  5:28 PM

Summary of Contents for FUQ71CVEB

Page 1: ...MANUAL MODELS 4 Way Blow Ceiling Suspended type SPLIT SYSTEM VRV SYSTEM FUQ71CVEB FXUQ71AVEB FUQ100CVEB FXUQ100AVEB FUQ125CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugu s T rk e 00...

Page 2: ...rdelo para futuras consultas Asimismo aseg rese de entregar este manual de instrucciones a un nuevo usuario Debido a que este manual de instrucciones est dedi cado a la unidad interior deber consultar...

Page 3: ...tes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especial izadas para su r...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched so...

Page 6: ...he control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove the...

Page 7: ...s a customized control system ask your local dealer for the operation that corre sponds to your system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Page 8: ...t bulb temperature The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ Read the operation manual attached to the out door unit Regarding places for installation Istheairco...

Page 9: ...is used to prevent the dis charge of melt water The remote controller displays the fan speed that is set When the outdoor temperature is high it takes some time until the indoor temperature reaches th...

Page 10: ...r the indoor temperature and humidity first use the COOLING OPERATION to lower the indoor temperature and then use the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the ind...

Page 11: ...conditioner It may decrease the effect or stop the operation Adjust the room temperature properly for a com fortable environment Avoid excessive heating or cooling Not doing so wastes electricity When...

Page 12: ...r filter It indicates after running for a certain time NOTE You may change the time of indication or Time to clean filter If the indoor unit is used in a space where the air is more contaminated ask y...

Page 13: ...ched to the indoor unit Refer to the figure shown below Suction grille Strap Knob Knob 2 Open the suction grille to 45 and lift it Then unhook it from the place to hook 3 places 3 Take out the air fil...

Page 14: ...order to activate the air condi tioner smoothly and to protect the air conditioner The display on the remote controller will be shown when the power circuit breaker is turned on HEATING OPERATION wit...

Page 15: ...installation but every time the power cir cuit breaker is turned off on 9 NOT MALFUNCTION OF THE AIR CONDITIONER For comfortable use do not turn off the power circuit breaker during seasonal use of t...

Page 16: ...unit Ask your local dealer for details on cleaning the indoor unit This cleaning requires a qualified service person Check the usage environment When the air conditioner is changed over to the HEATIN...

Page 17: ...vers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove the obstacle and make it well venti la...

Page 18: ...his time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditio...

Page 19: ...3P170549 16W EM12A001A 1404 HT 00_CV_3P170549 16W_01 fm Page 2 Saturday February 15 2014 6 19 PM...

Reviews: