The airflow direction becomes horizontal. (The
remote controller displays the airflow direction
that is set.)
•
During or after the DEFROST OPERATION, white
mist comes out from the air inlet or outlet of the air
conditioner.
(Refer to
“VI.”
on page 13.)
•
A hissing and “Shuh” sound may be heard during
this particular operation.
Regarding outside air temperature and heat-
ing capacity
•
The heating capacity of the air conditioner
declines as the outside air temperature falls.
In such a case, use the air conditioner in combi-
nation with other heating systems.
(When a combustion appliance is used, ventilate
the room regularly.)
Do not use the combustion appliance where the air
from the air conditioner is blown directly toward it.
•
When the warm air stays under the ceiling and
your feet are cold, we recommend that you use a
circulator (a fan to circulate the air inside the
room).
For details, consult your local dealer.
•
When the indoor temperature exceeds the set
temperature, the indoor unit discharges a gentle
breeze (switches to gentle wind). The airflow
direction becomes horizontal. (The remote con-
troller displays the fan speed and airflow direction
that are set.)
CHARACTERISTICS OF THE PROGRAM
DRY OPERATION
•
This operation lowers the humidity without lower-
ing the indoor temperature. The indoor tempera-
ture when the operation button is pressed will be
the set temperature. At this time, the fan speed
and temperature are set automatically, so the
remote controller does not display the fan speed
and set temperature.
To efficiently lower the indoor temperature and
humidity, first use the COOLING OPERATION to
lower the indoor temperature, and then use the
PROGRAM DRY OPERATION. When the indoor
temperature is lowered, airflow from the indoor
unit may stop.
•
When operating continuously at downward airflow
direction, air blows in the automatic set direction
for a period of time to prevent condensation on the
horizontal blades. (The remote controller displays
the airflow direction that is set.)
•
If the PROGRAM DRY OPERATION is used when
the indoor temperature is low, frost forms the heat
exchanger of the indoor unit. In this case, the air
conditioner automatically switches to the
DEFROST OPERATION for a while.
The low fan speed or a gentle wind is used to pre-
vent the discharge of melt water.
SOUND PRESSURE LEVEL
•
Sound pressure level is less than 70 dB(A).
AIRFLOW DIRECTION ADJUST
Airflow direction adjust can be individually set for
each air outlet. (BRC1E52 only)
•
Check the air outlet identification mark (refer to
page 5), and use the remote controller to set the
airflow direction. (For details, refer to the opera-
tion manual attached to the remote controller.)
•
The horizontal blades at the air outlet are closed
while the indoor unit stops.
AIRFLOW DIRECTION ADJUST
Press the AIRFLOW DIRECTION ADJUST/SET-
TING button to adjust the airflow direction.
The AIRFLOW DIRECTION dis-
play swings as shown left and the
airflow direction continuously var-
ies. (Automatic swing setting)
Press AIRFLOW DIRECTION
ADJUST/SETTING button to
select the air direction of your
choice.
The AIRFLOW DIRECTION dis-
play stops swinging and the air-
flow direction is fixed (Fixed
airflow direction setting).
Up and down adjustment
swing
01_EN_3P170549-16W.fm Page 7 Thursday, February 20, 2014 5:28 PM