Recommended mounting plate fixing spots
f
Position for the tape measure at symbol " "
b
Pocket for the pipe port cover
g
Gas pipe end
c
Tabs for placing a spirit level
h
Liquid pipe end
d
Through-the-wall hole Ø65 mm
e
Drain hose position
6.3.2 To drill a wall hole
CAUTION
For walls containing a metal frame or a metal board, use a wall embedded pipe and
wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire.
NOTICE
Be sure to seal the gaps around the pipes with sealing material (field supply), in order
to prevent water leakage.
1
Bore a 65 mm large feed-through hole in the wall with a downward slope
towards the outside.
2
Insert a wall embedded pipe into the hole.
3
Insert a wall cover into the wall pipe.
Ø65
a b
c
a
Wall embedded pipe
b
Putty
c
Wall hole cover
4
After completing wiring, refrigerant piping and drain piping, do NOT forget to
seal the gap with putty.
6.3.3 To remove the pipe port cover
INFORMATION
To connect the piping on right-side, right-bottom, left-side or left-bottom, the pipe
port cover MUST be removed.
1
Cut off the pipe port cover from inside the front grille using a coping saw.