background image

6

 | 

Energy saving and optimum operation

User reference guide

42

FTXTA30C2V1B(W)(B)

Daikin room air conditioner

4P518786-11K – 2023.05

6 Energy saving and optimum operation

INFORMATION

Even if the unit is turned OFF, it consumes electricity.

When  the  power  turns  back  on  after  a  power  break,  the  previously  selected
mode will be resumed.

CAUTION

NEVER expose little children, plants or animals directly to the airflow.

NOTICE

Do  NOT  place  objects  below  the  indoor  and/or  outdoor  unit  that  may  get  wet.
Otherwise  condensation  on  the  unit  or  refrigerant  pipes,  air  filter  dirt  or  drain
blockage may cause dripping, and objects under the unit may get dirty or damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air  conditioner  and  do  NOT  use
sprays near the unit. Doing so may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room  fumigation-type  insecticide.
Chemicals  could  collect  in  the  unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

Observe the following precautions to ensure the system operates properly.

Prevent direct sunlight from entering a room during cooling operation by using
curtains or blinds.

Make sure the area is well ventilated. Do NOT block any ventilation openings.

Ventilate often. Extended use requires special attention to ventilation.

Keep doors and windows closed. If the doors and windows remain open, air will
flow out of your room causing a decrease in the cooling or heating effect.

Be careful NOT to cool or heat too much. To save energy, keep the temperature
setting at a moderate level.

NEVER place objects near the air inlet or the air outlet of the unit. Doing so may
cause a reduced heating/cooling effect or stop operation.

Turn the breaker off when the unit is NOT used for longer periods of time. If the
breaker is on, the unit consumes electricity. Before restarting the unit, turn the
breaker on 6 hours before operation to ensure smooth running.

Condensation may form if the humidity is above 80% or if the drain outlet gets
blocked.

Adjust  the  room  temperature  properly  for  a  comfortable  environment.  Avoid
excessive  heating  or  cooling.  Notice  that  it  may  take  some  time  for  the  room
temperature  to  reach  the  set  temperature.  Consider  using  the  timer  setting
options.

Adjust the air flow direction to avoid cool air from gathering on the floor or warm
air  against  the  ceiling.  (Up  during  cooling  or  dry  operation  to  the  ceiling  and
down during heating operation.)

Avoid direct air flow to room inhabitants.

Summary of Contents for FTXTA30C2V1BW

Page 1: ...User reference guide Daikin room air conditioner FTXTA30C2V1BW FTXTA30C2V1BB...

Page 2: ...djust the airflow rate 23 5 5 Airflow direction 23 5 5 1 To adjust vertical airflow direction 24 5 5 2 To adjust horizontal airflow direction 24 5 5 3 To use 3D airflow direction 24 5 6 Comfort airflo...

Page 3: ...e NOT system malfunctions 54 8 1 1 Symptom A sound like water flowing is heard 54 8 1 2 Symptom A blowing sound is heard 54 8 1 3 Symptom A ticking sound is heard 54 8 1 4 Symptom A whistling sound is...

Page 4: ...he box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for...

Page 5: ...minor or moderate injury NOTICE Indicates a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Expl...

Page 6: ...physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards...

Page 7: ...ority Batteries are marked with the following symbol This means that the batteries may NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbo...

Page 8: ...esent Always have qualified service personnel confirm that the point of leakage has been repaired or corrected before resuming operation CAUTION ALWAYS use the wireless remote control or other user in...

Page 9: ...g materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless WARNING The appliance shall be s...

Page 10: ...age Splashed detergent on electric components such as motors may cause failure smoke or ignition DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the breaker OFF or pull...

Page 11: ...t will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may...

Page 12: ...ser interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface This manual describes only operation with this user interface If a...

Page 13: ...swing button g Comfort airflow and Intelligent eye operation button h Select button i Clock and open panel push 2 seconds button j OFF ON timer operation buttons k Weekly timer operation buttons l Fla...

Page 14: ...door unit receives a signal from the user interface Current temperature setting Airflow rate Automatic Airflow rate Indoor unit quiet Airflow rate High Airflow rate Medium high Airflow rate Medium Air...

Page 15: ...ithin 500 mm under the infrared signal receiver They may influence reception performance of the wireless remote control 1 Aim the signal transmitter at the infrared signal receiver on the indoor unit...

Page 16: ...es Fixing the user interface to the wall Inserting the batteries in the user interface Setting the brightness of the user interface display Setting the clock Setting the indoor unit position Turning o...

Page 17: ...ess remote control on the holder 4 4 The clock setting If the indoor unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock m...

Page 18: ...5 1 To set the brightness of the indoor unit display 1 Press for at least 2 seconds Result The menu appears on the display is blinking 2 Press 3 Press or to change the setting as follows is blinking B...

Page 19: ...seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blinks 3 Press to select the menu Result blinks 4 Press or to change the setting...

Page 20: ...A safety device might stop the operation of the system if the unit runs outside its operation range b Condensation and water dripping might occur if the unit runs outside its operation range 5 2 When...

Page 21: ...in the room Powerful To cool down or heat up the room quickly ON timer OFF timer To automatically turn ON or OFF the system Weekly timer To automatically turn ON or OFF the system on a weekly basis A...

Page 22: ...operating Operation mode Automatic Operation mode Drying Operation mode Cooling Operation mode Heating Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operati...

Page 23: ...tem directs the airflow differently depending on the user selection swinging or fixed position It does so by moving horizontal blades flaps or vertical blades louvers Setting Airflow direction Vertica...

Page 24: ...ppears from the LCD The louvers will stop moving INFORMATION When the unit is installed in a corner of a room the direction of the louvers should be facing away from the wall Efficiency will drop if a...

Page 25: ...tions Warming up Downward direction Vertical airflow direction INFORMATION If you want to deactivate the Vertical airflow function e g in case there is furniture or another object under the unit refer...

Page 26: ...ed by 2 C Cooling and drying If the temperature in the room is 30 C the temperature is raised by 2 C 30 C the temperature is raised by 1 C Fan only Decreases airflow rate About the Intelligent eye sen...

Page 27: ...ration will NOT increase the capacity of the unit if it already operates at maximum capacity 5 7 1 To start stop Powerful operation 1 Press to start Result is displayed on the LCD Powerful operation r...

Page 28: ...r consumption B Time a Maximum during normal operation b Maximum during Econo operation c Normal operation d Econo operation The diagram is for illustrative purposes only The maximum running current a...

Page 29: ...are generated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to preve...

Page 30: ...e Example The ON timer is set to 13 30 the unit will start operating at 13 30 12 hour countdown OFF ON timer The unit will stop start operating after the set number of hours Example The ON timer is se...

Page 31: ...timer is set the air conditioner automatically adjusts the temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperat...

Page 32: ...y 1 hour 3 Press or to confirm the setting Result and or and the set time are displayed on the LCD The timer lamp lights up The time displayed on the LCD will automatically count down by 1 hour for ev...

Page 33: ...o 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time ca...

Page 34: ...step 9 6 Press or to select the time The time can be set between 0 00 23 50 in 10 minute intervals 7 Press Result The time is set and and the temperature blink Note Press to return to the previous sc...

Page 35: ...to another day The complete reservation of the selected day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day...

Page 36: ...reservations To delete individual reservations Use this function if you want to delete a single reservation setting 1 Press Result The day of the week and the reservation number are displayed 2 Press...

Page 37: ...with minimum supported version of Android or iOS specified on app daikineurope com Internet line and communication device such as a modem router etc Wireless LAN access point Installed free ONECTA ap...

Page 38: ...eless LAN setting menu During setting always aim the wireless remote control at the infrared signal receiver on the unit INFORMATION Make sure operation is stopped before setting the wireless connecti...

Page 39: ...tedly or until the WPS setting display menu appears 3 Press to confirm the selection Result Beep sound is heard when the unit receives signal 4 Press the WPS button on your communication device e g ro...

Page 40: ...f the connection was unsuccessful 1 Hold for at least 5 seconds in the default screen Result The confirmation display menu appears 2 Press repeatedly or until the menu appears 3 Hold for at least 2 se...

Page 41: ...room air conditioner 4P518786 11K 2023 05 3 Hold for at least 2 seconds to confirm the selection Result Beep sound is heard when the unit receives signal Result Communication is OFF 4 Press to exit th...

Page 42: ...ains or blinds Make sure the area is well ventilated Do NOT block any ventilation openings Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed If the d...

Page 43: ...imum operation User reference guide 43 FTXTA30C2V1B W B Daikin room air conditioner 4P518786 11K 2023 05 Operate the system within the recommended temperature range 26 28 C for cooling and 20 24 C for...

Page 44: ...the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation...

Page 45: ...astic components or water leakage Splashed detergent on electric components such as motors may cause failure smoke or ignition DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operatio...

Page 46: ...will open Note Press and hold again for at least 2 seconds to close the front panel 3 Turn the power supply off 4 Pull down both locks on the back of the front panel 5 Open the front panel until the...

Page 47: ...Information RoHS compliant non toxic or corrosive There are no specific PPE recommendations Disposal shall comply with government and legal regulations governing the disposal of material Store in the...

Page 48: ...titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 weeks 7 7 To clean the titanium apatite deodorising filter and the silver particle filter A...

Page 49: ...he filter from the tabs of the filter frame and replace the filter with a new one INFORMATION Do NOT throw away the filter frame but use it again Dispose of the old filter as non flammable waste To or...

Page 50: ...ase it MUST be replaced 1 Open the front panel See 7 4 To open the front panel 446 2 Open the panel locks located on the back side of the panel 1 on each side a a a Panel lock 3 Push the right arm lig...

Page 51: ...ress and select operation 2 Press and start operation 3 After operation stops turn the breaker OFF 4 Clean the air filters and replace them in their original positions 5 Remove the batteries from the...

Page 52: ...operly except for the above mentioned cases and none of the above mentioned malfunctions is evident investigate the system in accordance with the following procedures Malfunction Measure If the system...

Page 53: ...nd windows to prevent wind from coming in Check if the unit operates in Econo or Outdoor unit quiet operation Refer to 5 8 Econo and Outdoor unit quiet operation 428 Check if there is any furniture di...

Page 54: ...o fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date possibly listed on the warr...

Page 55: ...em protection 8 1 10 Symptom Airflow rate setting does NOT resume when Comfort airflow is deactivated by ONECTA app If Comfort airflow operation is deactivated by ONECTA app the airflow rate does NOT...

Page 56: ...ecutive beeps indicate non corresponding codes To cancel the code display hold for 5 seconds The code will also disappear from the display if the button is NOT pressed within 1 minute System Error cod...

Page 57: ...r wireless LAN connection The following table provides a brief description of how to deal with some problems If none of the following solutions fix the problem go to app daikineurope com for more info...

Page 58: ...is OK Try resetting to the factory default and repeat the setting See To reset the connection setting to the factory default 440 Displayed indoor outdoor temperature humidity value in Online Controlle...

Page 59: ...8786 11K 2023 05 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units...

Page 60: ...ervice to the product Installation manual Instruction manual specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual spec...

Page 61: ......

Page 62: ......

Page 63: ......

Page 64: ...4P518786 11K 2023 05 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Reviews: