Daikin FTXTA30B2V1BB Operation Manual Download Page 4

3 About the system

Operation manual

4

FTXTA30B2V1B(W)(B)

Daikin room air conditioner

3P485919-13U – 2021.03

heater). The room size shall be as
specified in the General safety
precaution.

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies off. Otherwise, an
electric shock and injury may result.

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

CAUTION

Do NOT touch the heat exchanger fins.
These fins are sharp and could result
in cutting injuries.

WARNING

Be careful with ladders when working
in high places.

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker off or pull
out the supply cord. Otherwise, an
electric shock and injury may result.

WARNING

Stop operation and shut off the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electric shock or fire. Contact your
dealer.

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

CAUTION

The  indoor  unit  contains  radio  equipment,  minimum
separation  distance  between  the  radiating  part  of  the
equipment and the user is 10 cm.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

3.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation may cause an electric shock or fire. Contact
your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

3.1.1

Indoor unit display

a b c

d

e

a

ON/OFF button

b

Signal receiver

c

Timer lamp (orange)

d

Intelligent eye lamp (green)

e

Wireless adapter ON/OFF button

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Summary of Contents for FTXTA30B2V1BB

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXTA30B2V1BW FTXTA30B2V1BB ...

Page 2: ...rm reservations 12 5 10 4 To deactivate and reactivate Weekly timer operation 12 5 10 5 To delete reservations 12 5 11 Wireless LAN connection 13 5 11 1 Precautions when using the wireless LAN 13 5 11 2 To install the Daikin Residential Controller application 13 5 11 3 To set the wireless connection 13 6 Energy saving and optimum operation 14 7 Maintenance and service 15 7 1 Overview Maintenance a...

Page 3: ...vers are swinging and you move them forcibly by hand the mechanism will break CAUTION NEVER expose little children plants or animals directly to the airflow WARNING Do NOT place a flammable spray bottle near the air conditioner and do NOT use sprays near the unit Doing so may result in a fire CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in...

Page 4: ...aration distance between the radiating part of the equipment and the user is 10 cm NOTICE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art 3 1 Indoor unit CAUTION Do NOT insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed...

Page 5: ...nel push 2 seconds button j OFF ON timer operation buttons k Weekly timer operation buttons l Flash Streamer and Fireplace logic operation button m Econo and Outdoor unit quiet operation button n Mode button o Powerful button p Fan button INFORMATION Use hold for 2 seconds to open the front panel when you clean the air filters See 7 4 To open the front panel 415 3 2 2 To operate the user interface...

Page 6: ...to change the setting as follows is blinking Brightness is High Low Off 4 To confirm the selected setting press Result The brightness setting is changed Note The display automatically returns to the default screen after 60 seconds To return to the default screen sooner press twice 4 5 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close t...

Page 7: ...s when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During defrosting operation hot air is NOT blown from the indoor unit 5 2 1 To start stop operation mode and to set the temperature Unit is ...

Page 8: ... airflow direction 1 Press and Result and appear on the LCD The flaps horizontal blades and louvers vertical blades will begin to swing 2 To use fixed position press and when the flaps and louvers reach the desired position Result and disappear from the LCD The flaps and the louvers will stop moving 5 5 Comfort airflow and Intelligent eye operation You can use Comfort and Intelligent eye operation...

Page 9: ...Powerful operation CANNOT be used together with Econo Comfort airflow Intelligent eye and Outdoor unit quiet operation The last selected function takes priority Powerful operation will NOT increase the capacity of the unit if it already operates at maximum capacity 5 6 1 To start stop Powerful operation 1 Press to start Result is displayed on the LCD Powerful operation runs for 20 minutes after th...

Page 10: ...ace logic operation can be activated only in heating operation mode see 5 2 1 To start stop operation mode and to set the temperature 47 1 Press one or more times Result The setting will change as follows Display Operation Flash Streamer air cleaning Display Operation Fireplace logic Flash Streamer and Fireplace logic Both deactivated 2 To stop operation press until both symbols disappear from the...

Page 11: ... C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for each day Note Be sure to aim the user interface at the indoor unit and check for a receiving tone when settin...

Page 12: ...omplete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 411 5 10 3 To confirm reservations You can confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation numbe...

Page 13: ...ce Connect the wireless LAN to your smart device directly Connect the wireless LAN to your home network The wireless LAN will communicate with your smart device in your home network using a modem router or a similar device For more information and FAQ refer to app daikineurope com 1 Stop operation before setting the wireless connection 2 Use the user interface to select the wireless LAN setting me...

Page 14: ...Result is blinking The setting is reset to the factory default 4 Press to exit the menu Result The display will return to the default screen To turn off the wireless LAN connection You can turn off the wireless connection using the wireless adapter ON OFF button on the unit the user interface To use the wireless adapter ON OFF switch 1 Press the wireless adapter ON OFF switch Result The wireless a...

Page 15: ...d performing maintenance at least once a year However applicable legislation might require shorter maintenance intervals DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet...

Page 16: ...e deodorising filter and silver particle filter from the tabs 4 Wash the air filters with water or clean them with a vacuum cleaner 5 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash the air filters with a neutral detergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver ...

Page 17: ...e it MUST be replaced 1 Open the front panel See 7 4 To open the front panel 415 2 Open the panel locks located on the back side of the panel 1 on each side a a a Panel lock 3 Push the right arm lightly to the right to disconnect the shaft from the shaft slot on the right side a c b a Arm b Shaft c Shaft slot 4 Disconnect the front panel shaft from the shaft slot on the left side a c b a Arm b Sha...

Page 18: ...rn OFF the power supply The operation lamp flashes and you can check the error code by the user interface To display the error code see the user reference guide Notify your installer and report the error code If the system does NOT operate properly except for the above mentioned cases and none of the above mentioned malfunctions is evident investigate the system in accordance with the following pr...

Page 19: ......

Page 20: ...3P485919 13U 2021 03 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...

Reviews: