7 Maintenance and service

Operation manual

16

FTXTA30B2V1B(W)(B)

Daikin room air conditioner

3P485919-13U – 2021.03

Result: 

The front panel will open.

Note: 

 Press and hold 

 again for at least 2 seconds to close the

front panel.

3

Turn the power supply off.

4

Pull down both locks on the back of the front panel.

5

Open the front panel until the support fits into the fixing tab.

a

d

c

b

a

Lock (1 on each side)

b

Backside of the front panel

c

Fixing tab

d

Support

INFORMATION

If you CANNOT find the user interface or you use another
optional controller. Pull the front panel carefully up by hand
as shown in the following figure.

7.5

To clean the air filters

1

Push the tab at the centre of each air filter, then pull it down.

2

Pull out the air filters.

1

2

3

Remove the titanium apatite deodorising filter and silver particle
filter from the tabs.

4

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

5

Soak in lukewarm water for about 10 to 15 minutes.

INFORMATION

▪ If  the  dust  does  NOT  come  off  easily,  wash  the  air

filters  with  a  neutral  detergent  diluted  in  lukewarm
water. Dry the air filters in the shade.

▪ Be sure to remove the titanium apatite deodorising and

silver particle filters.

▪ It  is  recommended  to  clean  the  air  filters  every  2

weeks.

7.6

To clean the titanium apatite
deodorising filter and the silver
particle filter (Ag-ion filter)

INFORMATION

Clean the filter with water every 6 months.

1

Remove the silver particle filter (Ag-ion filter) from all 4 claws.

2

Remove the dust from the filter with a vacuum cleaner.

3

Soak the filter for 10 to 15 minutes in warm water.

Note: 

 Do NOT remove the filter from the frame.

4

After washing, shake off remaining water and dry the filter in the
shade. Do NOT wring out the filter when removing water.

Summary of Contents for FTXTA30B2V1BB

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXTA30B2V1BW FTXTA30B2V1BB ...

Page 2: ...rm reservations 12 5 10 4 To deactivate and reactivate Weekly timer operation 12 5 10 5 To delete reservations 12 5 11 Wireless LAN connection 13 5 11 1 Precautions when using the wireless LAN 13 5 11 2 To install the Daikin Residential Controller application 13 5 11 3 To set the wireless connection 13 6 Energy saving and optimum operation 14 7 Maintenance and service 15 7 1 Overview Maintenance a...

Page 3: ...vers are swinging and you move them forcibly by hand the mechanism will break CAUTION NEVER expose little children plants or animals directly to the airflow WARNING Do NOT place a flammable spray bottle near the air conditioner and do NOT use sprays near the unit Doing so may result in a fire CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in...

Page 4: ...aration distance between the radiating part of the equipment and the user is 10 cm NOTICE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art 3 1 Indoor unit CAUTION Do NOT insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed...

Page 5: ...nel push 2 seconds button j OFF ON timer operation buttons k Weekly timer operation buttons l Flash Streamer and Fireplace logic operation button m Econo and Outdoor unit quiet operation button n Mode button o Powerful button p Fan button INFORMATION Use hold for 2 seconds to open the front panel when you clean the air filters See 7 4 To open the front panel 415 3 2 2 To operate the user interface...

Page 6: ...to change the setting as follows is blinking Brightness is High Low Off 4 To confirm the selected setting press Result The brightness setting is changed Note The display automatically returns to the default screen after 60 seconds To return to the default screen sooner press twice 4 5 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close t...

Page 7: ...s when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During defrosting operation hot air is NOT blown from the indoor unit 5 2 1 To start stop operation mode and to set the temperature Unit is ...

Page 8: ... airflow direction 1 Press and Result and appear on the LCD The flaps horizontal blades and louvers vertical blades will begin to swing 2 To use fixed position press and when the flaps and louvers reach the desired position Result and disappear from the LCD The flaps and the louvers will stop moving 5 5 Comfort airflow and Intelligent eye operation You can use Comfort and Intelligent eye operation...

Page 9: ...Powerful operation CANNOT be used together with Econo Comfort airflow Intelligent eye and Outdoor unit quiet operation The last selected function takes priority Powerful operation will NOT increase the capacity of the unit if it already operates at maximum capacity 5 6 1 To start stop Powerful operation 1 Press to start Result is displayed on the LCD Powerful operation runs for 20 minutes after th...

Page 10: ...ace logic operation can be activated only in heating operation mode see 5 2 1 To start stop operation mode and to set the temperature 47 1 Press one or more times Result The setting will change as follows Display Operation Flash Streamer air cleaning Display Operation Fireplace logic Flash Streamer and Fireplace logic Both deactivated 2 To stop operation press until both symbols disappear from the...

Page 11: ... C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for each day Note Be sure to aim the user interface at the indoor unit and check for a receiving tone when settin...

Page 12: ...omplete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 411 5 10 3 To confirm reservations You can confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation numbe...

Page 13: ...ce Connect the wireless LAN to your smart device directly Connect the wireless LAN to your home network The wireless LAN will communicate with your smart device in your home network using a modem router or a similar device For more information and FAQ refer to app daikineurope com 1 Stop operation before setting the wireless connection 2 Use the user interface to select the wireless LAN setting me...

Page 14: ...Result is blinking The setting is reset to the factory default 4 Press to exit the menu Result The display will return to the default screen To turn off the wireless LAN connection You can turn off the wireless connection using the wireless adapter ON OFF button on the unit the user interface To use the wireless adapter ON OFF switch 1 Press the wireless adapter ON OFF switch Result The wireless a...

Page 15: ...d performing maintenance at least once a year However applicable legislation might require shorter maintenance intervals DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet...

Page 16: ...e deodorising filter and silver particle filter from the tabs 4 Wash the air filters with water or clean them with a vacuum cleaner 5 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash the air filters with a neutral detergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver ...

Page 17: ...e it MUST be replaced 1 Open the front panel See 7 4 To open the front panel 415 2 Open the panel locks located on the back side of the panel 1 on each side a a a Panel lock 3 Push the right arm lightly to the right to disconnect the shaft from the shaft slot on the right side a c b a Arm b Shaft c Shaft slot 4 Disconnect the front panel shaft from the shaft slot on the left side a c b a Arm b Sha...

Page 18: ...rn OFF the power supply The operation lamp flashes and you can check the error code by the user interface To display the error code see the user reference guide Notify your installer and report the error code If the system does NOT operate properly except for the above mentioned cases and none of the above mentioned malfunctions is evident investigate the system in accordance with the following pr...

Page 19: ......

Page 20: ...3P485919 13U 2021 03 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...

Reviews: