To change the air flow rate setting

5. Press “FAN setting button”.

• Indoor unit quiet operation

When the air flow is set to “ 

 ”, the noise from the indoor unit will become quieter. 

Use this when making the noise quieter.

The unit might lose power when the fan strength is set to weak level.

To change the air flow direction

(page 12.)

NOTE

DRY mode

AUTO or HEAT or COOL or FAN mode

The air flow rate setting is not variable.

Five levels of air flow rate setting from “ 

 ” to “ 

 ”

plus “ 

 ” “ 

 ” are available.

Note on HEAT operation

• Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating 

capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it is 
recommended to use another heating appliance in combination with the air conditioner.

• The heat pump system heats the room by circulating hot air around all parts of the room. After the 

start of heating operation, it takes some time before the room gets warmer.

• In heating operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, 

the system switches into defrosting operation to take away the frost.

• During defrosting operation, hot air does not flow out of indoor unit.

Note on DRY operation

• The computer chip works to rid the room of humidity while maintaining the temperature as 

much as possible. It automatically controls temperature and fan strength, so manual 
adjustment of these functions is unavailable.

Note on AUTO operation

• In AUTO operation, the system selects a temperature setting and an appropriate operation mode 

(COOL or HEAT) based on the room temperature at the start of the operation.

• The system automatically reselects setting at a regular interval to bring the room temperature to 

user-setting level.

• If you do not like AUTO operation, you can manually select the operation mode and setting 

you like.

Note on air flow rate setting

• At smaller air flow rates, the cooling (heating) effect is also smaller.

3P098586-1_Eng_1.book  Page 11  Wednesday, November 27, 2002  11:31 AM

Summary of Contents for FTXS50BVMB

Page 1: ...an ais Nederlands Espa ol Italiano Portugues Russian FTXS50BVMB FTKS50BVMB FTXS60BVMB FTKS60BVMB FTXS71BVMB FTKS71BVMB MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual Cover fm Page 1 Thursday Augu...

Page 2: ...0211 HT 3P098586 1 M02B051 Cover fm Page 2 Thursday August 22 2002 7 21 PM...

Page 3: ...AN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT SILENT Operation 15 HOME LEAVE Operation 16 INTELLIGENT EYE Operation 18 TIMER Operation 20 Note for Multi System...

Page 4: ...staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In o...

Page 5: ...nit with excessive water only use a slightly wet cloth Do not place things such as vessels containing water or anything else on top of the unit Water may penetrate into the unit and degrade electrical...

Page 6: ...4 Names of parts Indoor Unit Main unit control panel 7 14 11 12 13 4 3 15 1 2 9 10 8 6 5 The illustration shows a 50 class unit 17 16 3P098586 1_Eng_1 book Page 4 Wednesday November 27 2002 11 31 AM...

Page 7: ...e again to stop it The operation mode refer to the following table This switch is useful when the remote controller is missing 15 Packaging materials 50 class only If any packaging materials are inclu...

Page 8: ...elects the operation mode AUTO DRY COOL HEAT FAN page 10 8 SILENT button for OUTDOOR UNIT SILENT operation page 15 9 FAN setting button It selects the air flow rate setting 10 SENSOR button for INTELL...

Page 9: ...t used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali ba...

Page 10: ...the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller to direct sunlight Dust on the s...

Page 11: ...turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature range may cause a safety device to disable the system C TEMP ON OFF POWERFUL HOM...

Page 12: ...AT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATURE adjustment bu...

Page 13: ...ation it takes some time before the room gets warmer In heating operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation...

Page 14: ...once more The display will go blank The flap will stop moving To adjust the vertical blades louvers 3 Press SWING button The display will light up and the louvers will begin to swing 4 When the louver...

Page 15: ...Using three dimensional airflow circulates cold air which tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold...

Page 16: ...WERFUL button again NOTE Notes on POWERFUL operation In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor unit must be increased and the air flow rate be fixed to the m...

Page 17: ...peration is set on all operated indoor units However if using priority room setting see Note for multi system page 22 This function is available in COOL HEAT and AUTO modes This is not available in FA...

Page 18: ...E operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make sure is displayed in the remote controller display 2 Adjust the set temperature with or as you like 3 Adj...

Page 19: ...ush the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set temperature for normal operation Set the unit to HOME LEAVE Operation before leaving the living room w...

Page 20: ...TELLIGENT EYE operation 2 Press SENSOR button again EX C TEMP ON OFF POWERFUL HOME LEAVE MODE TIMER FAN SWING SILENT ON CANCEL OFF SWING 1 2 SENSOR When somebody in the room Normal operation When nobo...

Page 21: ...he sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during powerful operation Night set mode pa...

Page 22: ...ER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off Notes When TIMER is set the present time is not displayed Once you set ON OFF TIMER the time setting i...

Page 23: ...ER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown below ATTENTION In...

Page 24: ...se consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is...

Page 25: ...RFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when using OUTDOOR UNI...

Page 26: ...dowels on the left and right of the front panel with the slots then push them all the way in Close the front panel slowly Press the panel at both sides and the center CAUTION Units When the packaging...

Page 27: ...ukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Air purifying filter with photocatalytie deodorizing function gray The air purifying capacity of...

Page 28: ...oor unit and the outdoor unit Check that the earth wire is not disconnected or broken Check that the drain comes smoothly out of the drain hose during COOL or DRY operation If no drain water is seen w...

Page 29: ...In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when the air in the room is cooled int...

Page 30: ...r filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still blinks call the service shop wher...

Page 31: ...sons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop w...

Page 32: ...E SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT F3 HIGH TEMPERATURE...

Page 33: ...ROTECTOR WORKED OR FREEZE UP IN OPERATING UNIT OR STAND BY UNIT OVERLOAD RELAY WORKED OR HIGH DISCHARGE PIPE TEMPERATURE FAULTY COMPRESSOR START INPUT OVERCURRENT THERMISTOR OR CT ABNORMALITY HIGH TEM...

Page 34: ...32 MEMO 3P098586 1_Eng_1 book Page 32 Wednesday November 27 2002 11 31 AM...

Reviews: